When the power switch is pushed with the key in the cabin, the power management control ECU receives signals to switch the power source mode.
Use this troubleshooting procedure when the power source mode does not change to on (IG) but does change to on (ACC).
When the power management control ECU is replaced with a new one and the cable is connected to the negative (-) auxiliary battery terminal, the power source mode changes to on (IG).
When the auxiliary battery cable is disconnected and reconnected, the power source returns to the mode it was in before the auxiliary battery cable was disconnected.
Refer to DTC B2271 (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM (for Start Function)>SYSTEM DIAGRAM).
When using the GTS with the power switch off, perform either of the following: 1) Turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and vehicle begins, or 2) connect the GTS to the vehicle, select the vehicle type under manual mode, and then enter the following menus:
for Power Source Control: Body Electrical / Power Source Control / Trouble Codes.
for Entry&Start: Body Electrical / Entry&Start / Trouble Codes.
Make sure that no DTCs are output. If any DTCs are output, proceed to the Diagnostic Trouble Code Chart (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM (for Start Function)>DIAGNOSTIC TROUBLE CODE CHART).
The entry and start system uses multiplex communication. First perform the inspections in "How to Proceed with Troubleshooting" to confirm that there are no communication malfunctions before proceeding with troubleshooting (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM (for Start Function)>HOW TO PROCEED WITH TROUBLESHOOTING).
If the entry and start system is disabled through the customize function, enable the system before performing troubleshooting (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM (for Start Function)>CUSTOMIZE PARAMETERS).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After completing repairs, confirm that the problem does not occur.
| Problem Symptom | Data List Item | Active Test Item |
|---|---|---|
| Power source mode does not change to on (IG) but does change to on (ACC) | Power Source Control
·
Power Supply Condition ·
IG1 Relay Monitor (Inside) ·
IG2 Relay Monitor (Inside) ·
IG1 Relay Monitor (Outside) ·
IG2 Relay Monitor (Outside) ·
IG1 Circuit ·
IG2 Circuit |
- |
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
OK
(See pageGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING)
NG