METER / GAUGE SYSTEM > Hybrid System Indicator Malfunction |

| 1.CHECK CAN COMMUNICATION SYSTEM |
Check if CAN communication DTCs are output (Click here).
| Result | Proceed to |
| DTCs are not output. | A |
| DTCs are output. | B |
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING TECHSTREAM (HV SYSTEM INDICATOR) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Combination Meter / Active Test.
Check the indicator light operation according to the values in the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| HV System Indicator | HV system indicator | MIN, -50, 0, 100, 200, 300, 400, MAX | - |
|
| ||||
| OK | |
| 3.READ VALUE USING TECHSTREAM (HYBRID SYSTEM INDICATOR) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Enter the following menus: Body Electrical / Combination Meter / Data Test.
Check the values by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Hybrid System Indicator | Hybrid system indicator value/ Min.: -512, Max.: 511 | -512 to 511 | - |
|
| ||||
| OK | |
| 4.REPLACE COMBINATION METER ASSEMBLY |
Replace the combination meter assembly with a new or a known good one (Click here).
|
| ||||
| OK | ||
| ||