SMART KEY SYSTEM (for Start Function) > Power Source Mode does not Change to ON (ACC) |

| Problem Symptom | Data List Item | Active Test Item |
| Power source mode does not change to on (ACC) but does change to on (IG) | Power Source Control
| - |
| 1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Disconnect the G58 connector from the power management control ECU.
Disconnect the 3B connector from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G58-1 (ACCD) - 3B-37 | Always | Below 1 Ω |
| 3B-8 - Body ground | Always | Below 1 Ω |
| G58-1 (ACCD) or 3B-37 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).

| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3E-1 - MB-29 | Auxiliary battery voltage not applied to terminals 3B-37 and 3B-8 | 10 kΩ or higher |
| Auxiliary battery voltage applied to terminals 3B-37 and 3B-8 | Below 1 Ω |
|
| ||||
| OK | |
| 3.INSPECT POWER MANAGEMENT CONTROL ECU |
![]() |
Reconnect the G58 power management control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G58-1 (ACCD) - Body ground | Power switch off → Power switch on (ACC) | 1 V or less → 8.5 V or higher |
| *a | Component with harness connected (Power Management Control ECU) |
|
| ||||
| OK | ||
| ||