Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM

DTC    U1002    Lost Communication with Gateway Module (Power Management2)

for Preparation Click here


DESCRIPTION

  1. The power management control ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to the power management bus.
  2. When the power management control ECU receives a response signal from the ECUs connected to the power management bus, the power management control ECU recognizes and memorizes that the ECU is connected to the power management bus. Based on this memorized data, the power management control ECU monitors for malfunctions in the ECUs connected to the power management bus when communicating with those ECUs. If the power management control ECU cannot receive response signals from the ECUs that have been memorized as those connected to the power management bus, the power management control ECU determines that a malfunction exists.

DTC No.
DTC Detection Condition
Trouble Area
U1002
Power management control ECU cannot receive signals from all ECUs that have been memorized as those connected to the power management bus.
  1. Open or short in power management bus main wire or connector
  2. Open or short in power management bus branch wire or connector
  3. Power management control ECU
  4. ECM
  5. Air conditioning amplifier
  6. Skid control ECU (Brake booster with master cylinder)
  7. CAN No. 4 junction connector

HINT:
The diagnosis procedure is for when DTC U1002 is output by the power management control ECU (Intelligent tester display: Power Management2).


WIRING DIAGRAM


C210522E01


INSPECTION PROCEDURE

NOTICE:
  1. Turn the power switch off before measuring the resistances between CAN bus main wires and between CAN bus branch wires.
  2. Turn the power switch off before inspecting CAN bus wires for a ground short.
  3. After the power switch is turned off, check that the key reminder warning system and light reminder warning system are not operating.
  4. Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the power switch, any other switches or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.

HINT:
  1. Operating the power switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
  2. Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.

1.CHECK CAN BUS WIRE
  1. Turn the power switch off.



    A204441E23
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Switch Condition
    Specified Condition
    Result
    L6-31 (CA3P) - L6-30 (CA3N)
    Power switch off
    54 to 69 Ω
    Below 54 Ω:
    Short circuit between bus lines
    70 Ω or higher:
    Open circuit in a main bus line
    L6-31 (CA3P) - L6-4 (E12)
    Power switch off
    200 Ω or higher
    Below 200 Ω:
    CANH ground short
    L6-30 (CA3N) - L6-4 (E12)
    Power switch off
    200 Ω or higher
    Below 200 Ω:
    CANL ground short

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    Result
    L6-31 (CA3P) - L6-7 (AM21)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Below 6 kΩ:
    CANH +B short
    L6-30 (CA3N) - L6-7 (AM21)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Below 6 kΩ:
    CANL +B short

    Text in Illustration 
    *1
    Component with harness connector
    (Power Management Control ECU)

    Result:
    Result
    Proceed to
    OK
    A
    Open circuit in CAN main bus wire
    B
    Short circuit between bus lines
    C
    1. Ground short
    2. +B short
    D



B
Go to step 3

C
Go to step 6

D
Go to step 13
A


2.CHECK DTC OUTPUT
  1. Clear the DTCs.

  1. Turn the power switch off.

  1. Turn the power switch on (IG), recheck the DTC.

    Result:
    Result
    Proceed to
    U1002 is output from power management control ECU
    (Intelligent tester display/Power Management2)
    A
    Other DTC is output
    B



B
GO TO CIRCUITS INDICATED BY OUTPUT DTCS
A

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

3.CHECK FOR OPEN IN CAN BUS WIRE (POWER MANAGEMENT CONTROL ECU)


    A204446E07
  1. Disconnect the power management control ECU connector.
    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L6-31 (CA3P) - L6-30 (CA3N)
    Power switch off
    108 to 132 Ω



NG
Go to step 4
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

4.CHECK FOR OPEN IN CAN BUS WIRE (ECM)
  1. Reconnect the power management control ECU connector.



    A192807E25
  1. Disconnect the ECM connector.
    Text in Illustration 
    *1
    Front view of wire harness connector
    (to ECM)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A57-12 (CANP) - A57-4 (CANN)
    Power switch off
    108 to 132 Ω



NG
Go to step 5
OK

REPLACE ECM (Click here)  

5.CHECK FOR OPEN IN CAN BUS WIRE (CAN NO. 4 J/C MAIN WIRE)
  1. Reconnect the ECM connector.



    C210276E21
  1. Disconnect the CAN No. 4 junction connector.
    Text in Illustration 
    *1
    Front view of wire harness connector
    (to CAN No. 4 Junction Connector)
    *2
    to Power Management Control ECU
    *3
    to ECM

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Connected to
    L101-12 (CANH) - L101-1 (CANL)
    Power switch off
    108 to 132 Ω
    Power management control ECU
    L101-15 (CANH) - L101-4 (CANL)
    Power switch off
    108 to 132 Ω
    ECM

    Result:
    Result
    Proceed to
    OK
    A
    NG (to power management ECU main wire)
    B
    NG (to ECM main wire)
    C



B
REPAIR OR REPLACE CAN BUS MAIN WIRE OR CONNECTOR (CAN NO. 4 J/C - POWER MANAGEMENT CONTROL ECU)

C
REPAIR OR REPLACE CAN BUS MAIN WIRE OR CONNECTOR (CAN NO. 4 J/C - ECM)
A

REPLACE CAN NO. 4 JUNCTION CONNECTOR 

6.CHECK FOR SHORT IN CAN BUS WIRES (POWER MANAGEMENT CONTROL ECU)


    A204446E07
  1. Disconnect the power management control ECU connector.
    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L6-31 (CA3P) - L6-30 (CA3N)
    Power switch off
    108 to 132 Ω



NG
Go to step 7
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

7.CHECK FOR SHORT IN CAN BUS WIRES (ECM)
  1. Reconnect the power management control ECU connector.



    A192807E25
  1. Disconnect the ECM connector.
    Text in Illustration 
    *1
    Front view of wire harness connector
    (to ECM)

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A57-12 (CANP) - A57-4 (CANN)
    Power switch off
    108 to 132 Ω



NG
Go to step 8
OK

REPLACE ECM (Click here)  

8.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C MAIN WIRE)
  1. Reconnect the ECM connector.



    C210276E21
  1. Disconnect the CAN No. 4 junction connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Connected to
    L101-12 (CANH) - L101-1 (CANL)
    Power switch off
    108 to 132 Ω
    Power management control ECU
    L101-15 (CANH) - L101-4 (CANL)
    Power switch off
    108 to 132 Ω
    ECM

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to CAN No. 4 Junction Connector)
    *2
    to Power Management Control ECU
    *3
    to ECM

    Result:
    Result
    Proceed to
    OK
    A
    NG (to Power management ECU main wire)
    B
    NG (to ECM main wire)
    C



B
REPAIR OR REPLACE CAN BUS MAIN WIRE OR CONNECTOR (CAN NO. 4 J/C - POWER MANAGEMENT CONTROL ECU)

C
REPAIR OR REPLACE CAN BUS MAIN WIRE OR CONNECTOR (CAN NO. 4 J/C - ECM)
A


9.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C - SKID CONTROL ECU)


    C209401E10
  1. Disconnect the skid control ECU (brake booster with master cylinder) connector.
    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Skid Control ECU)



    C210276E22
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L101-14 (CANH) - L101-3 (CANL)
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to CAN No. 4 Junction Connector)
    *2
    to Skid Control ECU



NG
REPAIR OR REPLACE CAN BUS BRANCH WIRE OR CONNECTOR (CAN NO. 4 J/C - SKID CONTROL ECU)
OK


10.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C - A/C ECU)


    C188241E23
  1. Disconnect the air conditioning amplifier connector.
    Text in Illustration 
    *1
    Front view of wire harness connector
    (to Air Conditioning Amplifier)



    C210276E23
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L101-13 (CANH) - L101-2 (CANL)
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *1
    Front view of wire harness connector
    (to CAN No. 4 Junction Connector)
    *2
    to Air Conditioning Amplifier



NG
REPAIR OR REPLACE CAN BUS BRANCH WIRE OR CONNECTOR (CAN NO. 4 J/C - A/C ECU)
OK


11.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C)
  1. Reconnect the CAN No. 4 junction connector.



    A204446E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L6-31 (CA3P) - L6-30 (CA3N)
    Power switch off
    108 to 132 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    1. The resistance must be measured after the ECM and CAN No. 4 J/C wire harness connector are reconnected.
    2. The resistance must be measured after the skid control ECU and air conditioning amplifier connector are disconnected.



NG
REPLACE CAN NO. 4 JUNCTION CONNECTOR
OK


12.CHECK FOR SHORT IN CAN BUS WIRES (AIR CONDITIONING AMPLIFIER)
  1. Reconnect the air conditioning amplifier connector.



    A204446E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L6-31 (CA3P) - L6-30 (CA3N)
    Power switch off
    108 to 132 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    1. The resistance must be measured after the air conditioning amplifier connector is reconnected.
    2. The resistance must be measured after the skid control ECU connector is disconnected.

    Result:
    Result
    Proceed to
    OK (for LHD)
    A
    OK (for RHD)
    B
    NG
    C



B
REPLACE BRAKE BOOSTER WITH MASTER CYLINDER (SKID CONTROL ECU) (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A

REPLACE BRAKE BOOSTER WITH MASTER CYLINDER (SKID CONTROL ECU) (Click here)  

13.CHECK FOR SHORT IN CAN BUS WIRES (CAN NO. 4 J/C)
  1. Disconnect the CAN No. 4 junction connector.



  1. Measure the resistance according to the value(s) in the table below.


    C210570E01


    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    Purpose
    Connected to
    L101-12 (CANH) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANH ground short
    Power management control ECU
    L101-1 (CANL) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANL ground short
    L101-13 (CANH) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANH ground short
    Air conditioning amplifier
    L101-2 (CANL) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANL ground short
    L101-14 (CANH) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANH ground short
    Skid control ECU
    L101-3 (CANL) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANL ground short
    L101-15 (CANH) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANH ground short
    ECM
    L101-4 (CANL) - L61-4 (CG)
    Power switch off
    200 Ω or higher
    Inspection for CANL ground short
    L101-12 (CANH) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANH +B short
    Power management control ECU
    L101-1 (CANL) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANL +B short
    L101-13 (CANH) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANH +B short
    Air conditioning amplifier
    L101-2 (CANL) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANL +B short
    L101-14 (CANH) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANH +B short
    Skid control ECU
    L101-3 (CANL) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANL +B short
    L101-15 (CANH) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANH +B short
    ECM
    L101-4 (CANL) - L61-16 (BAT)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Inspection for CANL +B short

    HINT:
    1. It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check CAN Bus Wire inspection.
    2. Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check CAN Bus Wire inspection.


    Text in Illustration 
    *1
    Front view of wire harness connector
    (to CAN No. 4 Junction Connector)
    *2
    DLC3
    *3
    to Power Management Control ECU
    *4
    to Air Conditioning Amplifier
    *5
    to Skid Control ECU
    *6
    to ECM



NG
Go to step 14
OK

REPLACE CAN NO. 4 JUNCTION CONNECTOR 

14.CHECK FOR SHORT IN CAN BUS WIRES (ECU)
  1. Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus wire shorted to B+ or shorted to GND is connected (Click here).



    A204441E23
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Purpose
    L6-31 (CA3P) - L6-4 (E12)
    Power switch off
    200 Ω or higher
    Below 200 Ω:
    CANH ground short
    L6-30 (CA3N) - L6-4 (E12)
    Power switch off
    200 Ω or higher
    Below 200 Ω:
    CANL ground short
    L6-31 (CA3P) - L6-7 (AM21)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Below 6 kΩ:
    CANH +B short
    L6-30 (CA3N) - L6-7 (AM21)
    Cable disconnected from negative (-) battery terminal
    6 kΩ or higher
    Below 6 kΩ:
    CANL +B short

    HINT:
    1. It is only necessary to perform the inspection in the above table for the result (open or short circuit) that was obtained in the Check CAN Bus Wire inspection.
      Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check CAN Bus Wire inspection.
    2. If the resistance changes to normal when the connector is disconnected from the ECU, there may be a short in the ECU.

    Text in Illustration 
    *1
    Component with harness connector
    (Power Management Control ECU)



NG
REPAIR OR REPLACE CORRESPONDING ECU WIRE
OK

REPLACE CORRESPONDING ECU