DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |
DTC P102D O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | The heater current the specified value or less while the heater is operating (1 trip detection logic). |
|
| P0038 | The heater current reaches high limit. (Heater monitor IC high current limiter monitor input "Fail") (1 trip detection logic). |
|
| P0141 | The cumulative heater resistance correction value exceeds the threshold (2 trip detection logic). |
|
| P102D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
| Related DTCs | P0037: Heated oxygen sensor heater (sensor 2) range check (Low current) P0038: Heated oxygen sensor heater (sensor 2) range check (High current) P0141: Heated oxygen sensor heater performance (sensor 2) P102D: Heated oxygen sensor heater performance (sensor 2) |
| Required Sensors/Components (Main) | Heated oxygen sensor heater (sensor 2) |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P102D Once per driving cycle: P0141 |
| Duration | 0.5 seconds: P0037, P102D 2.064 seconds: P0038 10 seconds: P0141 |
| MIL Operation | Immediately: P0037, P0038, P102D 2 driving cycles: P0141 |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs are not stored | None |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or more |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Learned heater OFF current operation | Succeeded |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Heater ON current - Learned heater OFF current | 0.3 A or less |
| Command to heater output | ON |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or more |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Heated OFF current | More than 3.5 A |
| Heater monitor IC high current limiter monitor input | Fail |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or more |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Heater monitor IC high current limiter monitor input | Fail |
| Command to heater output | ON |
| All of the following conditions are met | - |
| Heated oxygen sensor heater circuit fail (P0037, P0038, P102D) | Not detected |
| Auxiliary battery voltage | 10.5 V or more |
| Fuel cut | OFF |
| Time after fuel cut ON to OFF | 30 seconds or more |
| Accumulated heater ON time | 100 seconds or more |
| Learned heater OFF current operation | Completed |
| Duration that heated oxygen sensor impedance is less than 15 kΩ | 2 seconds or more |
| All of the following conditions are met | - |
| Auxiliary battery voltage | 10.5 V or more |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Heated oxygen sensor heater low current fail (P0037) | Not detected |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Heater monitor IC high current limiter monitor input | Fail |
| Command to heater output | OFF |
| Heater OFF current | More than 3.5 A |
| Heater ON current - Learned heater OFF current | 0.3 A or less |
| Heated oxygen sensor heater ON current | 1 A or less |
| Both of the following conditions are met | - |
| Heater monitor IC high current limiter monitor input | Fail |
| Command to heater output | ON |
| Heater resistance | Varies with sensor element temperature (Example: More than 23 Ω) |
| Heated oxygen sensor heater ON current | More than 1 A |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor (Click here).
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D9-2 (+B) - Body ground | Power switch on (IG) | 11 to 14 V |
| *a | Front view of harness connector ( to Heated Oxygen Sensor (Sensor 2)) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D9-1 (HT1B) - D28-41 (HT1B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| D9-1 (HT1B) or D28-41 (HT1B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0037, P0038, P0141 OR P102D) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the power switch off and wait for at least 30 seconds.
Put the engine in inspection mode (maintenance mode) (Click here).
Drive the vehicle in accordance with the driving pattern described in the Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes / Pending.
Read the pending DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P0037, P0038, P0141 or P102D is output | B |
|
| ||||
| A | ||
| ||