DTC B1794 Open in Occupant Classification ECU Battery Positive Line |
| DTC No. | DTC Detections Conditions | Trouble Areas |
| B1794 |
|
|

| 1.CHECK AUXILIARY BATTERY VOLTAGE |
Measure the voltage of the auxiliary battery.
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (SOURCE VOLTAGE) |
![]() |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the connector from the occupant classification ECU.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| W3-1 (+B) - Body ground | Always | 11 to 14 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| W3-3 (GND) - Body ground | Always | Below 1 Ω |
| *1 | Front view of wire harness connector (to Occupant Classification ECU) |
|
| ||||
| OK | |
| 3.CHECK DTC |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the connector to the occupant classification ECU.
Connect the Techstream to the DLC3.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Clear the DTCs stored in the occupant classification ECU (Click here).
Clear the DTCs stored in the center airbag sensor assembly (Click here).
Turn the power switch off.
Turn the power switch on (IG), and wait for at least 10 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 4.REPLACE OCCUPANT CLASSIFICATION ECU |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Replace the occupant classification ECU (Click here).
| NEXT | |
| 5.PERFORM ZERO POINT CALIBRATION |
Connect the cable to the negative (-) auxiliary battery terminal.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Using the Techstream, perform Zero Point Calibration (Click here).
| NEXT | |
| 6.PERFORM SENSITIVITY CHECK |
Using the Techstream, perform Sensitivity Check (Click here).
| NEXT | ||
| ||