Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A82-123    Hybrid Battery Pack Cooling Fan 1

for Preparation Click here


DESCRIPTION

  1. Refer to the circuit description for DTC P0A84-123 .

DTC No.
DTC Detection Condition
Trouble Area
P0A82-123
The battery cooling blower assembly is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.*
(1 trip detection logic)
*: This DTC is not stored when "VMF Fan Motor Voltage" is too low or high.
  1. Battery cooling blower assembly
  2. Battery smart unit
  3. Power management control ECU
  4. HV battery intake duct
  5. Wire harness or connector

Related Data List 
DTC No.
Data List
P0A82-123
  1. Cooling Fan 0
  2. Cooling Fan Mode 1
The following items can be helpful when performing repairs:
Data List
  1. Temp of Batt TB1 to 3
  2. +B

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A84-123 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After the power switch is turned off, the display and navigation module display (HDD navigation system) records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 60 seconds before disconnecting the cable from the negative (-) battery terminal.

HINT:
  1. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
    4. Turn the battery cooling blower assembly off, then operate it in fan mode 1 through 6.
  2. Operation of the battery cooling blower can be confirmed by checking if air is sucked into the air intake port of the intake duct.

1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check and record any HV system DTCs, INF codes and freeze frame data.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Disconnect the Techstream from the DLC3.



B
GO TO DTC CHART (Click here)
A


2.CHECK DUCT AND BLOWER
  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217830E01
  1. Check that the No. 1 hybrid battery intake duct and battery cooling blower are not disconnected, damaged, or clogged with foreign matter, and that the acoustical materials have not peeled.

    OK:
    The duct and blower are not disconnected, damaged, or clogged with foreign matter and the acoustical materials have not peeled.

    Text in Illustration 
    *1
    No. 1 Hybrid Battery Intake Duct

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
CORRECT THE PROBLEM
OK


3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector A21 from the power management control ECU (Click here).

NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

NOTICE:
Check that the battery cooling blower assembly connector and power management control ECU connector are not loose or disconnected.



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.



    A217831E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    S14-3 (SI0) or A21-29 (SI0) - Body ground
    10 kΩ or higher
    S14-3 (SI0) - A21-29 (SI0)
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (Power Management Control ECU)

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the power management control ECU connector (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK POWER MANAGEMENT CONTROL ECU (GROUND SHORT CHECK)
  1. Remove the power management control ECU (Click here).



    A217832E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Specified Condition
    A21-29 (SI0) - L5-5 (E01)
    10 kΩ or higher
    A21-29 (SI0) - L6-5 (E02)
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (to Power Management Control ECU)

  1. Install the power management control ECU (Click here).



NG
REPLACE POWER MANAGEMENT CONTROL ECU (Click here)
OK


5.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A217836E03
  1. Disconnect connector c1 from the battery smart unit.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery cooling blower assembly connector and battery smart unit connector are not loose or disconnected.



    A217837E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) - c1-7 (VM)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) or c1-7 (VM) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the S14 connector of battery cooling blower assembly.

  1. Connect the c1 connector of the battery smart unit.

  1. Install the hybrid battery junction block assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.READ VALUE USING TECHSTREAM (VMF Fan Motor Voltage 1)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E07
  1. While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

    Result:
    Result
    Proceed to
    Both of the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector are 0 V.
    A
    Except above.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



B
Go to step 8
A


7.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).

  1. Disconnect connector c1 from the battery smart unit.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery smart unit connector and battery cooling blower assembly connector are not loose or disconnected.

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A314776E01
  1. While the battery cooling fan is operating, measure the voltage on the wire harness side of the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    c1-7 (VM) - Body ground
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

    Result:
    Result
    Proceed to
    The actual measured value at the battery cooling blower assembly connector remains 0 V.
    A
    The actual measured value at the battery cooling blower assembly connector is not 0 V.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Connect the c1 connector of the battery smart unit.

  1. Install the hybrid battery junction block assembly (Click here).



B
REPLACE BATTERY SMART UNIT (Click here)
A

REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)  

8.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E07
  1. While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

    Result:
    Result
    Proceed to
    Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V or less.
    A
    Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V more than.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



B
REPLACE BATTERY SMART UNIT (Click here)
A

REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)