DTC P0A82-123 Hybrid Battery Pack Cooling Fan 1 |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0A82-123 | The battery cooling blower assembly is malfunctioning and the actual speed is not within the specified range of the target speed calculated by the ECU.* (1 trip detection logic) *: This DTC is not stored when "VMF Fan Motor Voltage" is too low or high. |
|
| DTC No. | Data List |
| P0A82-123 |
|
| 1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check and record any HV system DTCs, INF codes and freeze frame data.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Disconnect the Techstream from the DLC3.
|
| ||||
| A | |
| 2.CHECK DUCT AND BLOWER |
Remove the No. 1 hybrid battery exhaust duct (Click here).
![]() |
Check that the No. 1 hybrid battery intake duct and battery cooling blower are not disconnected, damaged, or clogged with foreign matter, and that the acoustical materials have not peeled.
| *1 | No. 1 Hybrid Battery Intake Duct |
Install the No. 1 hybrid battery exhaust duct (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Disconnect connector A21 from the power management control ECU (Click here).
Remove the No. 1 hybrid battery exhaust duct (Click here).
![]() |
Disconnect connector S14 from the battery cooling blower assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| S14-3 (SI0) or A21-29 (SI0) - Body ground | 10 kΩ or higher |
| S14-3 (SI0) - A21-29 (SI0) | Below 1 Ω |
| *a | Front view of wire harness connector (to Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector (Power Management Control ECU) |
Connect the battery cooling blower assembly connector.
Install the No. 1 hybrid battery exhaust duct (Click here).
Connect the power management control ECU connector (Click here).
Connect the cable to the negative (-) battery terminal.
|
| ||||
| OK | |
| 4.CHECK POWER MANAGEMENT CONTROL ECU (GROUND SHORT CHECK) |
Remove the power management control ECU (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| A21-29 (SI0) - L5-5 (E01) | 10 kΩ or higher |
| A21-29 (SI0) - L6-5 (E02) | 10 kΩ or higher |
| *a | Component without harness connected (to Power Management Control ECU) |
Install the power management control ECU (Click here).
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Disconnect connector S14 from the battery cooling blower assembly.
![]() |
Disconnect connector c1 from the battery smart unit.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| S14-2 (VM0) - c1-7 (VM) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| S14-2 (VM0) or c1-7 (VM) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Battery Cooling Blower Assembly) |
| *b | Rear view of wire harness connector (to Battery Smart Unit) |
Connect the S14 connector of battery cooling blower assembly.
Connect the c1 connector of the battery smart unit.
Install the hybrid battery junction block assembly (Click here).
|
| ||||
| OK | |
| 6.READ VALUE USING TECHSTREAM (VMF Fan Motor Voltage 1) |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery exhaust duct (Click here).
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
![]() |
While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition |
| S14-2 (VM0) - S14-4 (GND0) | Battery cooling blower is operating |
| *a | Component with harness connected (Battery Cooling Blower Assembly) |
| Result | Proceed to |
| Both of the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector are 0 V. | A |
| Except above. | B |
Install the No. 1 hybrid battery exhaust duct (Click here).
|
| ||||
| A | |
| 7.CHECK BATTERY COOLING BLOWER ASSEMBLY |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
Disconnect connector c1 from the battery smart unit.
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
![]() |
While the battery cooling fan is operating, measure the voltage on the wire harness side of the battery cooling blower assembly connector.
| Tester Connection | Condition |
| c1-7 (VM) - Body ground | Battery cooling blower is operating |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
| Result | Proceed to |
| The actual measured value at the battery cooling blower assembly connector remains 0 V. | A |
| The actual measured value at the battery cooling blower assembly connector is not 0 V. | B |
Connect the c1 connector of the battery smart unit.
Install the hybrid battery junction block assembly (Click here).
|
| ||||
| A | ||
| ||
| 8.CHECK BATTERY COOLING BLOWER ASSEMBLY |
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Remove the No. 1 hybrid battery exhaust duct (Click here).
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Clear DTCs and freeze frame data.
Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
![]() |
While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition |
| S14-2 (VM0) - S14-4 (GND0) | Battery cooling blower is operating |
| *a | Component with harness connected (Battery Cooling Blower Assembly) |
| Result | Proceed to |
| Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V or less. | A |
| Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V more than. | B |
Install the No. 1 hybrid battery exhaust duct (Click here).
|
| ||||
| A | ||
| ||