DTC    P0A84-123    Hybrid Battery Pack Cooling Fan 1

for Preparation Click here


DESCRIPTION


  1. The speed of the battery cooling blower assembly is controlled by the power management control ECU. Battery cooling blower assembly power is supplied when the FCTL terminal of the power management control ECU turns on the battery blower relay. The power management control ECU sends command signals SI0 to the battery cooling blower assembly to get the fan speed corresponding to the HV battery temperature. Information about the voltage applied to the battery cooling blower assembly (VM) is sent to the power management control ECU as a monitor signal using serial communication via the battery smart unit.


    A141849E03


DTC No.
DTC Detection Condition
Trouble Area
P0A84-123
Both of the following conditions are met due to the battery cooling blower system malfunction:
(1 trip detection logic)
  1. The speed calculated based on the battery cooling blower assembly output voltage (VM) is not within the target control speed range.
  2. The battery cooling blower assembly speed is excessively low when a certain level speed is requested (possibility of open or short to ground in connected circuits, short to +B or motor locking).
  1. Wire harness or connector
  2. No. 2 integration relay
  3. Battery cooling blower assembly
  4. Battery smart unit
  5. Power management control ECU

Related Data List 
DTC No.
Data List
P0A84-123
  1. Cooling Fan 0
  2. Cooling Fan Mode 1
The following items can be helpful when performing repairs:
Data List
  1. Temp of Batt TB1 to 3
  2. +B

WIRING DIAGRAM


A298785E02


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After the power switch is turned off, the display and navigation module display (HDD navigation system) records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 60 seconds before disconnecting the cable from the negative (-) battery terminal.

HINT:
  1. As the battery cooling blower assembly speed is too low, there is a possibility of open or short to ground in connected circuits, short to +B or motor locking.
  2. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Connect the Techstream to the DLC3.
    2. Turn the power switch on (IG).
    3. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
    4. Select fan mode 6 and operate the battery cooling blower assembly.
  3. Operation of the battery cooling blower can be confirmed by checking if air is sucked into the air intake port of the intake duct.

1.CHECK FOR DTCS (DTC P0AFC-123 IS OUTPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check and record any HV system DTCs, INF codes and freeze frame data.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Disconnect the Techstream from the DLC3.



B
GO TO DTC CHART
A


2.PERFORM ACTIVE TEST USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

    NOTICE:
    If the active test cannot be performed, skip it and proceed to the next step to check fan operates and air is sucked. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.

  1. Select air volume mode 6 in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.

  1. Check that the fan operates and air is sucked into the inlet duct.

    HINT:
    The cooling fan may not stop even when turning the cooling fan off in the "Driving the Battery Cooling Fan" active test. This is due to HV system control and not a malfunction.

    OK:
    The fan operates.



NG
Go to step 7
OK


3.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A217836E03
  1. Disconnect connector c1 from the battery smart unit.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery cooling blower assembly connector and battery smart unit connector are not loose or disconnected.



    A217837E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) - c1-7 (VM)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-2 (VM0) or c1-7 (VM) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the S14 connector of battery cooling blower assembly.

  1. Connect the c1 connector of the battery smart unit.

  1. Install the hybrid battery junction block assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.READ VALUE USING TECHSTREAM (VMF Fan Motor Voltage1)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E07
  1. While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

    Result:
    Result
    Proceed to
    Both of the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector are 0 V.
    A
    Except above.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
Go to step 6
OK


5.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).

  1. Disconnect connector c1 from the battery smart unit.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery smart unit connector and battery cooling blower assembly connector are not loose or disconnected.

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A314776E01
  1. While the battery cooling fan is operating, measure the voltage on the wire harness side of the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    c1-7 (VM) - Body ground
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

    Result:
    Result
    Proceed to
    The actual measured value at the battery cooling blower assembly connector remains 0 V.
    A
    The actual measured value at the battery cooling blower assembly connector is not 0 V.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Connect the c1 connector of the battery smart unit.

  1. Install the hybrid battery junction block assembly (Click here).



NG
REPLACE BATTERY SMART UNIT (Click here)
OK

CHECK BATTERY COOLING BLOWER ASSEMBLY 

Go to step 17

6.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / All Data / VMF Fan Motor Voltage 1.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E07
  1. While the battery cooling fan is operating, compare the value in the data list (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.

    Standard:
    Tester Connection
    Condition
    S14-2 (VM0) - S14-4 (GND0)
    Battery cooling blower is operating

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

    Result:
    Result
    Proceed to
    Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V or less.
    A
    Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measured value at the battery cooling blower assembly connector is 1 V more than.
    B

    HINT:
    Compare the values in each air volume mode (1 to 6). If the active test cannot be performed, compare the values only in the current air volume mode.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
REPLACE BATTERY SMART UNIT (Click here)
OK

CHECK BATTERY COOLING BLOWER ASSEMBLY 

Go to step 17

7.CHECK NO. 2 INTEGRATION RELAY (BATT FAN)
  1. Remove the No. 2 integration relay from the engine room junction block assembly (Click here).



  1. Measure the resistance according to the value(s) in the table below.


    A217835E01

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1C-1 - 1A-8
    Battery voltage is applied across terminals 1A-6 and 1A-7
    Below 1 Ω
    No battery voltage is applied across terminals 1A-6 and 1A-7
    10 kΩ or higher


    Text in Illustration 
    *1
    No. 2 integration Relay
    *2
    BATT FAN Fuse
    *3
    BATT FAN Relay
    -
    -

  1. Install the No. 2 integration relay (Click here).



NG
Go to step 15
OK


8.CHECK HARNESS AND CONNECTOR (VOLTAGE)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Clear DTCs and freeze frame data.

    NOTICE:
    When DTCs are cleared, freeze frame data and INF codes are also cleared.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.

    NOTICE:
    If the active test cannot be performed, skip it and proceed to the next step to check voltage. In accordance with fail-safe system operation, the power management control ECU sends a command to operate the battery cooling fan.

  1. Enter the following menus: All Data / VMF Fan Motor Voltage 1.

  1. Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.



    A217833E08
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    S14-1 (IG0) - Body ground
    Battery cooling blower is operating
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

    NOTICE:
    Measure the voltage on the wire side of the connector that is part of the battery cooling blower.

  1. Turn the power switch off.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
Go to step 11
OK


9.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).



    A248440E01
  1. Using a service wire, connect terminals 3 (SI0) and 4 (GND0) of the battery cooling blower assembly connector.

    Standard Voltage:
    Terminal Connection
    Switch Condition
    Specified Condition
    S14-3 (SI0) - S14-4 (GND0)
    Power switch on (IG)
    Fan operates

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Cooling Blower Assembly)

NOTICE:
Measure the voltage on the wire side of the connector that is part of the battery cooling blower.

HINT:
If DTCs are output after the check, clear the DTCs using the Techstream.

  1. Turn the power switch off.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).



NG
REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)
OK


10.CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER - POWER MANAGEMENT CONTROL ECU)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

  1. Disconnect connector A21 from the power management control ECU (Click here).

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the battery cooling blower assembly connector and power management control ECU connector are not loose or disconnected.



    A217831E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-3 (SI0) - A21-29 (SI0)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    S14-3 (SI0) or A21-29 (SI0) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the power switch on (IG).

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. If the power switch is turned on (IG) with the service plug grip removed, DTC P0A0D-350 for the interlock switch system will be stored. If this DTC is output, clear the DTC using the Techstream (Click here).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-3 (SI0) - Body ground
    Power switch on (IG)
    Below 1 V

  1. Turn the power switch off.

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the power management control ECU connector (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

11.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - POWER MANAGEMENT CONTROL ECU)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect connector A21 from the power management control ECU (Click here).

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the No. 2 integration relay connector and power management control ECU connector are not loose or disconnected.

  1. Remove the No. 2 integration relay (Click here).



    A249209E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1A-7 - A21-4 (FCTL)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to No. 2 Integration Relay)
    *b
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

  1. Connect the cable to the negative (-) battery terminal.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A21-4 (FCTL) - Body ground
    Power switch off
    Below 1 V
    Power switch on (IG)
    Below 1 V

    NOTICE:
    If the power switch is turned on (IG) with the connector disconnected, DTCs will be stored. If DTCs are output, clear them using the Techstream (Click here).

  1. Connect the power management control ECU connector (Click here).

  1. Install the No. 2 integration relay (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect connector L5 from the power management control ECU (Click here).

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A212482E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-5 (E01) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

  1. Connect the power management control ECU connector (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


13.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Disconnect connector L6 from the power management control ECU (Click here).

    NOTICE:
    Before disconnecting the connector, check that it is not loose or disconnected.



    A212483E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L6-5 (E02) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)

    NOTICE:
    When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.

  1. Connect the power management control ECU connector (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


14.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Remove the No. 2 integration relay (Click here).

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the No. 2 integration relay connector and battery cooling blower assembly connector are not loose or disconnected.



    A249210E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1A-8 - S14-1 (IG0)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Front view of wire harness connector
    (to No. 2 Integration Relay)

  1. Install the No. 2 integration relay (Click here).

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

15.REPLACE NO. 2 INTEGRATION RELAY
  1. Replace the No. 2 integration relay (Click here).


NEXT


16.CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY COOLING BLOWER ASSEMBLY)
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Remove the No. 2 integration relay (Click here).

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.

    NOTICE:
    1. Before disconnecting the connector, check that it is not loose or disconnected.
    2. Check that the No. 2 integration relay connector and battery cooling blower assembly connector are not loose or disconnected.



    A249210E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-1 (IG0) - Terminals other than 1A-8 and body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Battery Cooling Blower Assembly)
    *b
    Front view of wire harness connector
    (to No. 2 Integration Relay)

  1. Install the No. 2 integration relay (Click here).

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


17.CHECK BATTERY COOLING BLOWER ASSEMBLY
  1. Disconnect the cable from the negative (-) battery terminal.

  1. Remove the No. 1 hybrid battery exhaust duct (Click here).



    A217834
  1. Disconnect connector S14 from the battery cooling blower assembly.



    A221313E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    S14-1 (IG0) - S14-4 (GND0) and body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Component without harness connected
    (Battery Cooling Blower Assembly)

  1. Connect the battery cooling blower assembly connector.

  1. Install the No. 1 hybrid battery exhaust duct (Click here).

  1. Connect the cable to the negative (-) battery terminal.



NG
REPLACE BATTERY COOLING BLOWER ASSEMBLY (Click here)
OK

RECOVERY TO NORMAL