Home › Engine / Hybrid System › 2ZR-FXE ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > Fuel Pump Control Circuit

for Preparation Click here


DESCRIPTION

When the NE signal is input to the ECM, Tr is turned on, current flows to the coil of the circuit opening relay, the relay switches on, power is supplied to the fuel pump and the fuel pump operates.
While the NE signal is generated (engine running), the ECM keeps Tr on (circuit opening relay on) and the fuel pump also keeps operating.

A217608E06


WIRING DIAGRAM


A275625E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE C/OPN RELAY)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.

  1. Check whether the fuel pump operation sound occurs when performing the Active Test on the Techstream.

    OK:
    Fuel pump operating sound occurs.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT INTEGRATION RELAY (C/OPN RELAY)
  1. Inspect the integration relay (Click here).



NG
REPLACE INTEGRATION RELAY (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - ECM)
  1. Disconnect the ECM connector.

  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1B-7 - A57-8 (FC)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - IG2 RELAY)
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1A-4 - 1B-6
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (C/OPN RELAY - FUEL PUMP)
  1. Disconnect the fuel pump connector.

  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the integration relay connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    1B-8 - R11-4 (B)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):

    Tester Connection
    Condition
    Specified Condition
    1B-8 or R11-4 (B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (FUEL PUMP - BODY GROUND)
  1. Disconnect the fuel pump connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):

    Tester Connection
    Condition
    Specified Condition
    R11-5 (E) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.INSPECT FUEL PUMP
  1. Inspect the fuel pump (Click here).

    HINT:
    Perform "Inspection After Repair" after replacing the fuel pump (Click here).



NG
REPLACE FUEL PUMP (Click here)
OK


8.CHECK ECM POWER SOURCE CIRCUIT
  1. Check the ECM power source circuit (Click here).



NG
REPAIR OR REPLACE ECM POWER SOURCE CIRCUIT
OK

REPLACE ECM (Click here)