Home › Engine / Hybrid System › 1NZ-FXE ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > VC Output Circuit

for Preparation Click here


DESCRIPTION

The ECM constantly generates a 5 V power source voltage from the auxiliary battery voltage supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power source voltage to the sensors through the VC output circuit.

A240424E16

When the VC circuit is short-circuited, the microprocessor in the ECM and the sensors that are supplied with power through the VC circuit are inactivated because power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.

HINT:
Under normal conditions, the MIL is illuminated when the power switch is turned on (IG). The MIL goes off when the power switch on (READY).


WIRING DIAGRAM


A275904E01


INSPECTION PROCEDURE

1.CHECK MIL
  1. Check that the Malfunction Indicator Lamp (MIL) lights up when the power switch is turned on (IG).

    OK:
    MIL lights up.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK COMMUNICATION BETWEEN INTELLIGENT TESTER AND ECM
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the tester on.

  1. Check the communication between the tester and ECM.

    Result 
    Result
    Proceed to
    Communication is not possible
    A
    Communication is possible
    B



B
GO TO MIL CIRCUIT (Click here)
A


3.CHECK MIL (THROTTLE POSITION SENSOR)
  1. Disconnect the throttle body with motor assembly connector.

  1. Turn the power switch on (IG).

  1. Check the MIL.

    Result 
    Result
    Proceed to
    MIL does not illuminate
    A
    MIL illuminates
    B

    HINT:
    Perform "Inspection After Repair" after replacing the throttle body with motor assembly (Click here).



B
REPLACE THROTTLE BODY WITH MOTOR ASSEMBLY (Click here)
A


4.CHECK MIL (MANIFOLD ABSOLUTE PRESSURE SENSOR)
  1. Disconnect the manifold absolute pressure sensor connector.

  1. Turn the power switch on (IG).

  1. Check the MIL.

    Result 
    Result
    Proceed to
    MIL does not illuminate
    A
    MIL illuminates
    B



B
REPLACE MANIFOLD ABSOLUTE PRESSURE SENSOR (Click here)
A


5.CHECK HARNESS AND CONNECTOR
  1. Disconnect the throttle body with motor assembly connector.

  1. Disconnect the manifold absolute pressure sensor connector.

  1. Disconnect the ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C10-115 (VCTA) - Body ground
    Always
    10 kΩ or higher
    C10-118 (VCPM) - Body ground
    Always
    10 kΩ or higher

    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C9-115 (VCTA) - Body ground
    Always
    10 kΩ or higher
    C9-118 (VCPM) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)