The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during blower unit removal/installation are shown below.
*1: When performing learning using the GTS.
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>INTELLIGENT CLEARANCE SONAR SYSTEM>CALIBRATION
1. PRECAUTION
Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.
2.REMOVE AIR CONDITIONER UNIT ASSEMBLY
87211A
3.REMOVE NO. 2 AIR DUCT (for LHD)
87211
4.REMOVE NO. 1 AIR DUCT (for RHD)
82143
5.REMOVE NO. 3 INSTRUMENT PANEL WIRE (w/ PTC Heater)
87130D
6.REMOVE BLOWER ASSEMBLY
for LHD:
Disconnect the connector.
Disengage 4 guides.
Remove the 2 screws.
Disengage the 2 claws and 3 guides and remove the blower assembly from the air conditioning radiator assembly.
for RHD:
Disconnect the connector.
Disengage 2 guides.
Remove the 2 screws.