The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during shutting valve (water valve) removal/installation are shown below.
*1: When performing learning using the GTS.
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>INTELLIGENT CLEARANCE SONAR SYSTEM>CALIBRATION
G9200
1.REMOVE INVERTER WITH CONVERTER ASSEMBLY
2.DRAIN ENGINE COOLANT (for Engine)
16671
3.REMOVE FLOW SHUTTING VALVE (WATER VALVE)
Disconnect the 3 connectors.
Disengage the clamp to disconnect the wire harness from the water outlet.
Slide the clip and disconnect the No. 3 radiator hose.
Slide the clip and disconnect the No. 9 water by-pass hose.
Remove the 2 nuts.
Slide the clip and disconnect the No. 10 water by-pass hose and remove the water outlet with the flow shutting valve (water valve).
Remove the water outlet gasket from the cylinder head sub-assembly.
Secure the water outlet in a vise between aluminum plates.
Do not damage the water outlet.
Remove the 2 bolts and flow shutting valve (water valve).
Remove the gasket from the flow shutting valve (water valve).