Home › Engine / Hybrid System › 2ZR-FXE COOLING › FLOW SHUTTING VALVE
RM3210E _51 Engine / Hybrid System _047499 2ZR-FXE COOLING _0233535 FLOW SHUTTING VALVE A

2ZR-FXE COOLING  FLOW SHUTTING VALVE  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during shutting valve (water valve) removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Lane departure alert system (w/ Steering Control System) (Click here)
Intelligent clearance sonar system
Simple intelligent parking assist system*1
Pre-crash safety system
Parking assist monitor system (Click here)
Initialize back door lock Power door lock control system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


(Click here)
for SFI system (w/ Canister Pump Module)

Replacement of ECM


Perform Vehicle Identification Number (VIN) registration MIL comes on (Click here)
for SFI system (w/o Canister Pump Module)

Replacement of ECM


Perform Vehicle Identification Number (VIN) or frame number registration MIL comes on (Click here)

*1: When performing learning using the GTS.

Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>INTELLIGENT CLEARANCE SONAR SYSTEM>CALIBRATION

PROCEDURE

Hide G9200 1.REMOVE INVERTER WITH CONVERTER ASSEMBLY

Hide 2.DRAIN ENGINE COOLANT (for Engine)

Hide 16671 3.REMOVE FLOW SHUTTING VALVE (WATER VALVE)

A375612

a.

Disconnect the 3 connectors.


b.

Disengage the clamp to disconnect the wire harness from the water outlet.


c.
A375613

Slide the clip and disconnect the No. 3 radiator hose.


d.
A375614

Slide the clip and disconnect the No. 9 water by-pass hose.


e.
A375615

Remove the 2 nuts.


f.

Slide the clip and disconnect the No. 10 water by-pass hose and remove the water outlet with the flow shutting valve (water valve).


g.

Remove the water outlet gasket from the cylinder head sub-assembly.


h.

Secure the water outlet in a vise between aluminum plates.

NOTICE:

Do not damage the water outlet.



i.
A375617

Remove the 2 bolts and flow shutting valve (water valve).


j.
A375618

Remove the gasket from the flow shutting valve (water valve).