HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P0E7100  Generator Execution Torque Performance  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that the generator torque execution value does not correspond to the torque command value from the hybrid vehicle control ECU to the generator (MG1). The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Inside of inverter Inverter with converter assembly internal circuit malfunction
Hybrid vehicle transaxle assembly
·

Generator (MG1) internal malfunction (entry of foreign matter, etc.)

·

Open or short circuit in the generator coils


Inverter low-voltage circuit The connectors are not connected properly
Motor cable (for MG1)
·

Open or short circuit in the motor cable

·

Defective motor cable connection condition


Hybrid vehicle control ECU Hybrid vehicle control ECU internal circuit malfunction


DESCRIPTION

For a description of the inverter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P0D2D16

When the actual generator torque is different from the generator torque requested by the motor generator control ECU (MG ECU), the motor generator control ECU (MG ECU) stores this DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0E7100 Generator Execution Torque Performance Generator (MG1) torque execution monitoring malfunction:
The difference between the generator torque requested by the motor generator control ECU and actual motor torque is large.
(1 trip detection logic)
·

Hybrid vehicle transaxle assembly

·

Motor cable

·

Inverter with converter assembly

·

Hybrid vehicle control ECU

·

Wire harness or connector


Comes on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P0E7100
·

Generator Torque

·

Target Generator Torque



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Turn the power switch on (READY) and wait for 5 seconds or more.

7.

Depress the accelerator pedal half way or more and accelerate the vehicle to 40 km/h (25 mph) using the engine.

8.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for the Generator High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Generator High-voltage Circuit

Refer to the wiring diagram for the Shut Down Signal Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit

CAUTION / NOTICE / HINT

CAUTION:
·

Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·

After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Result:
Result Proceed to
P0E7100 only is output, or DTCs except the ones in the tables below are also output. A
DTCs of hybrid control system in the tables below are output. B
DTCs of motor generator control system in the tables below are output. C


Table 1
Malfunction Content Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased
P1C7D49 Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased
P1C7E49 Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased
P1C7F49 Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased
System Main Relay or High Voltage Circuit Malfunction Hybrid control system P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module
P0A1A49 Drive Motor "A" Control Module
P0A1B1F Drive Motor "B" Control Module
P1C2A1C Hybrid Powertrain Control Module
P1C2A49 Generator A/D Converter Circuit
P1C2B1C Drive Motor "A" A/D Converter Circuit
P1C2B49 Drive Motor "B" A/D Converter Circuit
P313383 Generator Control Module Malfunction
P313386 Drive Motor Control Module Malfunction
P313387 Drive Motor "B" Control Module Malfunction
P313483 Generator Position Sensor Angle Malfunction
P313486 Drive Motor "A" Position Sensor Angle Malfunction
P313487 Drive Motor "B" Position Sensor Angle Malfunction
Hybrid control system P0A1B49 Generator Position Sensor REF Signal Cycle Malfunction
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum
P0A6012 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery
P0A6014 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open
P0A601C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range
P0A6312 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery
P0A6314 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open
P0A631C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range
P0BE512 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery
P0BE514 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BE912 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery
P0BE914 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BED12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery
P0BED14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BFD62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C6413 Generator Position Sensor Circuit "A" Circuit Open
P0C6416 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C6417 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C6913 Generator Position Sensor Circuit "B" Circuit Open
P0C6916 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C6917 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0D2D16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E3116 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold
P0E3117 DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range
P1CAC49 Generator Position Sensor Internal Electronic Failure
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
Hybrid control system P0C7600 Hybrid/EV Battery System Discharge Time Too Long
P0D2D1C Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range
P0E311C Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range
P1C2D62 Drive Motor "A" Inverter before Boosting Voltage Sensor Signal Compare Failure
System malfunction Motor generator control system P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed
P0A7A73 Generator Inverter Actuator Stuck Closed

HINT:
·

P0E7100 may be output as a result of the malfunction indicated by the DTCs above.

1.

The chart above is listed in inspection order of priority.

2.

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





e.

Turn the power switch off.



A

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION

B

C

2.CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility
Tester Display
Diagnosis Related Information
50005 395 1056

d.

Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

Powertrain > Motor Generator > Trouble Codes
50001 395

e.

Read the diagnosis related information and freeze frame data of DTC P0E7100.

Result:
Result Proceed to
DTC P31241F or P312487 is listed in Diagnosis Related Information. A
DTC P31241F and P312487 are not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. B
Other than above C



f.

Turn the power switch off.



A

B

C

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

4.CHECK SHUT DOWN SIGNAL CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK SHUT DOWN SIGNAL CIRCUIT

NEXT

5.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
5.CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Generator High-voltage Circuit

HINT:

If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.


Result:
Proceed to
NEXT



NEXT

REPLACE INVERTER WITH CONVERTER ASSEMBLY