This DTC is stored when there is an open or short circuit in the communication line between the front sensors and the ECU, or when there is a malfunction in a front sensor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1AEC | Front Sensor Communication Malfunction | An open or short circuit in the communication line between the front sensors and ECU or a malfunction in a front sensor during initialization mode after the power switch is turned on (IG). | ·
Front ultrasonic sensor circuit ·
Harness or connector ·
Clearance warning ECU assembly |
Check for DTCs.
Clear the DTCs.
Recheck for DTCs.
| Result | Proceed to |
|---|---|
| DTC C1AEC is output | A |
| No DTCs are output | B |
A
B
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
Disconnect the F26 clearance warning ECU assembly connector.
Disconnect the B1 front corner ultrasonic sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F26-4 (BOF) - B1-4 (BI) | Always | Below 1 Ω |
| F26-8 (SOF) - B1-5 (SI) | Always | Below 1 Ω |
| F26-6 (E5) - B1-6 (EI) | Always | Below 1 Ω |
| F26-4 (BOF) or B1-4 (BI) - Body ground | Always | 10 kΩ or higher |
| F26-8 (SOF) or B1-5 (SI) - Body ground | Always | 10 kΩ or higher |
| F26-6 (E5) or B1-6 (EI) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B2 front center ultrasonic sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B1-1 (BO) - B2-4 (BI) | Always | Below 1 Ω |
| B1-2 (SO) - B2-5 (SI) | Always | Below 1 Ω |
| B1-3 (EO) - B2-6 (EI) | Always | Below 1 Ω |
| B1-1 (BO) or B2-4 (BI) - Body ground | Always | 10 kΩ or higher |
| B1-2 (SO) or B2-5 (SI) - Body ground | Always | 10 kΩ or higher |
| B1-3 (EO) or B2-6 (EI) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B3 front center ultrasonic sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B2-1 (BO) - B3-4 (BI) | Always | Below 1 Ω |
| B2-2 (SO) - B3-5 (SI) | Always | Below 1 Ω |
| B2-3 (EO) - B3-6 (EI) | Always | Below 1 Ω |
| B2-1 (BO) or B3-4 (BI) - Body ground | Always | 10 kΩ or higher |
| B2-2 (SO) or B3-5 (SI) - Body ground | Always | 10 kΩ or higher |
| B2-3 (EO) or B3-6 (EI) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B4 front corner ultrasonic sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B3-1 (BO) - B4-4 (BI) | Always | Below 1 Ω |
| B3-2 (SO) - B4-5 (SI) | Always | Below 1 Ω |
| B3-3 (EO) - B4-6 (EI) | Always | Below 1 Ω |
| B3-1 (BO) or B4-4 (BI) - Body ground | Always | 10 kΩ or higher |
| B3-2 (SO) or B4-5 (SI) - Body ground | Always | 10 kΩ or higher |
| B3-3 (EO) or B4-6 (EI) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Front Corner Ultrasonic Sensor LH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (BI) - 6 (EI) | Always | 10 kΩ or higher |
| 4 (BI) - 1 (BO) | Always | Below 1 Ω |
| 5 (SI) - 2 (SO) | Always | Below 30 Ω |
| 6 (EI) - 3 (EO) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Front Center Ultrasonic Sensor LH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (BI) - 6 (EI) | Always | 10 kΩ or higher |
| 4 (BI) - 1 (BO) | Always | Below 1 Ω |
| 5 (SI) - 2 (SO) | Always | Below 30 Ω |
| 6 (EI) - 3 (EO) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Front Center Ultrasonic Sensor RH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (BI) - 6 (EI) | Always | 10 kΩ or higher |
| 4 (BI) - 1 (BO) | Always | Below 1 Ω |
| 5 (SI) - 2 (SO) | Always | Below 30 Ω |
| 6 (EI) - 3 (EO) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Front Corner Ultrasonic Sensor RH) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (BI) - 6 (EI) | Always | 10 kΩ or higher |
| 4 (BI) - 1 (BO) | Always | Below 1 Ω |
| 5 (SI) - 2 (SO) | Always | Below 30 Ω |
| 6 (EI) - 3 (EO) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>TOYOTA PARKING ASSIST-SENSOR SYSTEM>C1AE1
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC C1AEC is output | A |
| No DTCs are output | B |
A
B
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>TOYOTA PARKING ASSIST-SENSOR SYSTEM>C1AE2
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC C1AEC is output | A |
| No DTCs are output | B |
A
B
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>TOYOTA PARKING ASSIST-SENSOR SYSTEM>C1AE3
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC C1AEC is output | A |
| No DTCs are output | B |
A
B
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>TOYOTA PARKING ASSIST-SENSOR SYSTEM>C1AE4
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTC C1AEC is output | A |
| No DTCs are output | B |
A
B