Home › ENGINE · 3ZR-FAE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0037    Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

DTC    P0038    Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2)

DTC    P102D    O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON

for Preparation Click here


DESCRIPTION

  1. Refer to DTC P0136 (Click here).

HINT:
  1. Sensor 2 refers to the sensor mounted behind the three way catalytic converter and located far from the engine assembly.

  2. When any of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the heated oxygen sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.


    A210603E02


DTC No.
DTC Detection Condition
Trouble Area
P0037
The heated oxygen sensor heater current is below 0.3 A when the heater operates with +B higher than 10.5 V (1 trip detection logic).
  1. Open in heated oxygen sensor heater circuit
  2. Heated oxygen sensor heater (sensor 2)
  3. Integration relay (EFI MAIN relay)
  4. ECM
P0038
The heated oxygen sensor heater current exceeds 2 A when the heater operates (1 trip detection logic).
  1. Short in heated oxygen sensor heater circuit
  2. Heated oxygen sensor heater (sensor 2)
  3. Integration relay (EFI MAIN relay)
  4. ECM
P102D
The heater current is higher than the specified value while the heater is not operating (1 trip detection logic).
ECM


WIRING DIAGRAM

Refer to DTC P2195 (Click here).

INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)


    A210493E01
  1. Disconnect the heated oxygen sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    2 (HT1B) - 1 (+B)
    20°C (68°F)
    11 to 16 Ω
    2 (HT1B) - 3 (E2)
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


2.CHECK HEATED OXYGEN SENSOR (POWER SOURCE)


    A210494E01
  1. Disconnect the heated oxygen sensor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage (for LHD):
    for LHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E105-1 (+B) - Body ground
    Ignition switch ON
    11 to 14 V
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E94-2 (+B) - Body ground
    Ignition switch ON
    11 to 14 V

  1. Reconnect the heated oxygen sensor connector.



NG
Go to step 5
OK


3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)


    A210496E01
  1. Disconnect the heated oxygen sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E105-2 (HT1B) - B32-63 (HT1B)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E94-1 (HT1B) - B32-63 (HT1B)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E105-2 (HT1B) or B32-63 (HT1B) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E94-1 (HT1B) - B32-63 (HT1B)
    Always
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (HEATED OXYGEN SENSOR - ECM)
OK


4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0037, P0038, P102D)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Start the engine.

  1. Allow the engine to idle for 1 minute or more.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.
    Result 
    Result
    Proceed to
    DTC is not output
    A
    DTC P0037, P0038 or P102D is output
    B



B
REPLACE ECM (Click here)
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

5.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - INTEGRATION RELAY (EFI MAIN))


    A210495E01
  1. Disconnect the heated oxygen sensor connector.

  1. Remove the integration relay (EFI MAIN relay) from the engine room No. 1 relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E105-1 (+B) - 1A-4
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E94-2 (+B) - 1A-4
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E105-1 (+B) or 1A-4 - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    E94-2 (+B) or 1A-4 - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (HEATED OXYGEN SENSOR - INTEGRATION RELAY (EFI MAIN))
OK

GO TO ECM POWER SOURCE CIRCUIT (Click here)