Home › Engine / Hybrid System › 2AR-FE ENGINE CONTROL › SFI SYSTEM
RM30B0U _51 Engine / Hybrid System _008971 2AR-FE ENGINE CONTROL _0049217 SFI SYSTEM C

2AR-FE ENGINE CONTROL  SFI SYSTEM  P0441  Evaporative Emission Control System Incorrect Purge Flow  


DTC SUMMARY

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P0441 Evaporative Emission Control System Incorrect Purge Flow One of the following conditions met:
·

Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure is measured at start and at end of leak check.

If stabilized pressure higher than [second reference pressure x 0.2], ECM determines that purge VSV stuck open.

·

After EVAP leak check performed, purge VSV turned on (open), and atmospheric air introduced into EVAP system. Reference pressure is measured at start and at end of check.

If pressure does not return to near atmospheric pressure, ECM determines that purge VSV stuck closed.

·

While engine running, following conditions successively met:

·

Negative pressure not created in EVAP system when purge VSV turned on (open)

·

EVAP system pressure change less than 0.4 kPa(gauge) [3 mmHg(gauge)] when vent valve turned on (closed)

·

Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa(gauge) [0.75 mmHg(gauge)]



·

Purge VSV

·

Purge line

·

Connector/wire harness (purge VSV - ECM)

·

ECM

·

Canister pump module

·

Canister (filter inside canister clogged)

·

Leak from EVAP system


Comes on DTC stored DTC for Mexico Models
- Applies

DTC No. Monitoring Item Detection Timing Detection Logic
P0441 Purge VSV (Vacuum Switching Valve) stuck open While ignition switch off 2 trip
Purge VSV stuck closed While ignition switch off
Purge flow While engine running

DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>EVAP System

MONITOR DESCRIPTION

The 2 monitors, key-off and purge flow, are used to detect malfunctions relating to DTC P0441. The key-off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours after the ignition switch is turned off. The purge flow monitor runs while the engine is running.

1.

KEY-OFF MONITOR

5 hours* after the ignition switch is turned off, the electric leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV opened and then EVAP system pressure is measured by ECM.
A large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612
1.604,2.156 1.75,2.438 false 2.458,1.094 2.823,0.99 false 2.406,1.646 2.792,1.625 false 2.563,2.021 2.833,2.021 false 1.208,3.302 1.208,3.427 false 1.302,4.479 1.583,4.5 false 2.323,3.188 1.854,3.948 false 5.083,0.958 5.083,1.083 false 5.323,2.198 5.448,2.156 false 5.135,4.479 5.448,4.5 false 5.083,3.302 5.083,3.438 false 1.604,1.083 1.698,0.677 false 0.635,2.063 1.469,1.948 false 0.604,1.656 1.146,1.74 false 1.781,1.583 1.854,1.354 1.854,1.354 2.802,1.354 false 5.656,1.594 5.719,1.365 5.719,1.365 6.677,1.365 false 5.708,3.948 5.771,3.719 5.771,3.719 6.729,3.719 false 1.219,0.948 1.198,1.125 false 0.198,0.156 0.51,0.344 0.313,0.188 10 *a 0.229,2.719 0.594,2.906 0.365,0.188 10 *c 4.469,0.167 4.792,0.365 0.323,0.198 10 *b 3.542,3.625 3.792,3.813 0.25,0.188 10 *e 0.417,1.552 0.646,1.74 0.229,0.188 10 *7 4.469,2.698 4.792,2.885 0.323,0.188 10 *d 1.635,0.51 2.167,0.688 0.531,0.177 10 *9 2.854,0.917 3.49,1.094 0.635,0.177 10 *10 2.854,1.25 3.094,1.427 0.24,0.177 10 *3 2.854,1.552 3.24,1.729 0.385,0.177 10 *11 2.844,1.948 3.125,2.125 0.281,0.177 10 *12 0.469,2 0.698,2.208 0.229,0.208 10 *8 1.76,2.448 2.073,2.625 0.313,0.177 10 *5 1.135,3.458 1.427,3.635 0.292,0.177 10 *1 1.146,4.396 1.375,4.573 0.229,0.177 10 *6 2.333,3.063 3.094,3.24 0.76,0.177 10 *4 3.552,4.208 3.802,4.438 0.25,0.229 10 *f 5.01,1.104 5.302,1.281 0.292,0.177 10 *1 5.146,2.125 5.375,2.302 0.229,0.177 10 *6 5,3.458 5.229,3.635 0.229,0.177 10 *2 4.979,4.385 5.208,4.563 0.229,0.177 10 *6 6.75,3.646 7.031,3.823 0.281,0.177 10 *4 6.719,1.281 6.958,1.458 0.24,0.177 10 *3 1.115,1.135 1.406,1.313 0.292,0.177 10 *1
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 Fuel Tank
*11 Canister Pump Module *12 Canister Filter
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure


1.

Purge VSV stuck open

In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second reference pressure x 0.2], the ECM interprets this as the purge VSV being stuck open. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).

A283585
0.094,0.052 2.646,0.24 2.552,0.188 10 EVAP Pressure when Purge Stuck Open: 0.354,0.625 1.094,0.854 0.74,0.229 10 Purge VSV 0.385,1.083 1.125,1.313 0.74,0.229 10 Vent Valve 0.135,1.427 1.104,1.833 0.969,0.406 10 Leak Detection Pump 0.094,2 1.135,2.229 1.042,0.229 10 EVAP Pressure 0.198,2.323 0.75,2.583 0.552,0.26 10 Positive 0.188,2.615 0.75,2.917 0.563,0.302 10 Negative 0.104,3.083 1.073,3.479 0.969,0.396 10 First Reference Pressure 0.438,4.146 1.167,4.396 0.729,0.25 10 Sequence 0.146,4.396 1.167,4.677 1.021,0.281 10 Time (Seconds) 1.708,4.156 1.938,4.333 0.229,0.177 10 A 2.563,4.156 2.792,4.333 0.229,0.177 10 B 3.823,2.125 4.583,2.333 0.76,0.208 10 Malfunction 5.135,4.156 5.365,4.333 0.229,0.177 10 D 5.729,4.156 5.958,4.333 0.229,0.177 10 E 1.677,4.385 2,4.604 0.323,0.219 10 60 2.5,4.385 2.823,4.604 0.323,0.219 10 360 3.427,4.385 4.583,4.583 1.156,0.198 10 Within 15 minutes 5.104,4.375 5.427,4.594 0.323,0.219 10 10 5.708,4.375 5.917,4.583 0.208,0.208 10 60 3.771,3.271 4.083,3.5 0.313,0.229 10 OK 3.885,1.625 4.167,1.833 0.281,0.208 10 ON 3.906,1.115 4.25,1.333 0.344,0.219 10 ON 5.083,0.563 5.417,0.75 0.333,0.188 10 ON 6.188,0.417 6.917,0.656 0.729,0.24 10 ON: Open 6.188,0.677 7.083,0.906 0.896,0.229 10 OFF: Closed 6.198,0.969 7,1.146 0.802,0.177 10 ON: Closed 6.208,1.229 6.917,1.417 0.708,0.188 10 OFF: Vent 6.271,2.635 6.938,3.385 0.667,0.75 10 [Second Reference Pressure] x 0.2 3.875,4.156 4.104,4.333 0.229,0.177 10 C

2.

Purge VSV stuck closed

In operation D, the canister pressure sensor measures the EVAP (Evaporative Emission) system pressure. The pressure measurement for the purge VSV monitor begins when the purge VSV is turned on (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa(gauge) [2.25 mmHg(gauge)] or higher, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores the DTC (2 trip detection logic).

A283586
0.094,0.063 3.083,0.292 2.99,0.229 10 EVAP Pressure when Purge VSV Stuck Closed: 0.354,0.583 1.167,0.833 0.813,0.25 10 Purge VSV 0.396,1.042 1.167,1.25 0.771,0.208 10 Vent Valve 0.135,1.458 1.104,1.875 0.969,0.417 10 Leak Detection Pump 0.083,2.021 1.167,2.24 1.083,0.219 10 EVAP Pressure 0.208,2.354 0.75,2.583 0.542,0.229 10 Positive 0.198,2.677 0.833,2.917 0.635,0.24 10 Negative 0.115,3.073 1.094,3.469 0.979,0.396 10 First Reference Pressure 0.438,4.167 1.083,4.406 0.646,0.24 10 Sequence 0.135,4.448 1.167,4.667 1.031,0.219 10 Time (Seconds) 2.573,4.177 2.792,4.375 0.219,0.198 10 B 3.917,4.188 4.135,4.385 0.219,0.198 10 C 5.146,4.188 5.365,4.385 0.219,0.198 10 D 5.729,4.188 5.948,4.385 0.219,0.198 10 E 1.719,4.177 1.938,4.375 0.219,0.198 10 A 1.688,4.448 1.917,4.667 0.229,0.219 10 60 2.51,4.448 2.833,4.667 0.323,0.219 10 360 3.448,4.448 4.667,4.667 1.219,0.219 10 Within 15 minutes 5.708,4.438 6,4.667 0.292,0.229 10 60 5.115,4.438 5.333,4.667 0.219,0.229 10 10 4.354,2.063 4.677,2.313 0.323,0.25 10 OK 3.865,1.646 4.188,1.896 0.323,0.25 10 ON 3.865,1.135 4.188,1.385 0.323,0.25 10 ON 5.073,0.594 5.396,0.844 0.323,0.25 10 ON 6.271,0.448 7,0.646 0.729,0.198 10 ON: Open 6.281,0.719 7.125,0.948 0.844,0.229 10 OFF: Closed 6.271,1.01 7.083,1.219 0.813,0.208 10 ON: Closed 6.281,1.281 7,1.51 0.719,0.229 10 OFF: Vent 3.885,2.885 4.667,3.083 0.781,0.198 10 Malfunction


2.

PURGE FLOW MONITOR

The purge flow monitor consists of 2 monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.

A283587
0.083,0.063 2.833,0.302 2.75,0.24 10 EVAP Pressure During Purge Flow Monitor: 2.031,0.708 2.833,0.917 0.802,0.208 10 Purge VSV 2.063,1.063 2.833,1.25 0.771,0.188 10 Vent Valve 1.75,1.427 2.833,1.667 1.083,0.24 10 EVAP Pressure 3.583,0.646 4,0.833 0.417,0.188 10 Open 3.625,1.021 4.5,1.25 0.875,0.229 10 ON (Closed) 4.427,1.271 5.26,1.469 0.833,0.198 10 Malfunction 4.427,1.573 6.833,1.813 2.406,0.24 10 0.1 kPa(gauge) [0.75 mmHg(gauge)] 4.427,1.958 7.073,2.188 2.646,0.229 10 0.4 kPa(gauge) [3 mmHg(gauge)] 2.813,2.417 4.333,2.667 1.521,0.25 10 1st Monitor 2nd Monitor 3.229,1.781 3.5,2 0.271,0.219 10 OK 4.125,2.146 4.417,2.333 0.292,0.188 10 OK


·

The 1st monitor

While the engine is running and the purge VSV is on (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.

·

The 2nd monitor

The vent valve is turned on (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.4 kPa(gauge) [3 mmHg(gauge)], the ECM interprets this as the purge VSV being stuck closed, illuminates the MIL and stores DTC P0441 (2 trip detection logic).


Atmospheric pressure check:

In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after conduction of the purge flow monitor, is measured by the ECM.

MONITOR STRATEGY

Required Sensors/Components (Main) Purge VSV
Canister pump module
Required Sensors/Components (Related) -
Frequency of Operation Once per driving cycle
Duration Within 20 minutes: Purge VSV stuck open/close
Within 10 minutes: Purge flow
MIL Operation 2 driving cycles
Sequence of Operation None

TYPICAL ENABLING CONDITIONS

All
Monitor runs whenever the following DTCs are not stored None

Key-off Monitor
Atmospheric pressure 70 kPa(abs) [525 mmHg(abs)] or higher, and less than 110 kPa(abs) [825 mmHg(abs)]
Battery voltage 10.5 V or higher
Vehicle speed Less than 4 km/h (2.5 mph)
Ignition switch Off
Time after key-off 5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key-off Conditions 1 and 2
1. Duration that vehicle is driven 5 minutes or more
2. EVAP purge operation Performed
Engine coolant temperature 4.4°C (40°F) or higher, and less than 35°C (95°F)
Intake air temperature 4.4°C (40°F) or higher, and less than 35°C (95°F)

Purge Flow Monitor
Engine Running
Engine coolant temperature 4.4°C (40°F) or higher
Intake air temperature 4.4°C (40°F) or higher
Canister pressure sensor malfunction Not detected
Purge VSV Not operated by scan tool
EVAP system check Not operated by scan tool
Battery voltage 10 V or higher
Purge duty-cycle 8% or higher

TYPICAL MALFUNCTION THRESHOLDS

Purge VSV Stuck Open
EVAP pressure when vacuum introduction is complete Higher than [reference pressure x 0.2]

Purge VSV Stuck Closed
EVAP pressure change after purge VSV is open Less than 0.3 kPa(gauge) [2.25 mmHg(gauge)]

Purge Flow
Both of the following conditions are met: Conditions 1 and 2
1. EVAP pressure change when purge flow is started Less than 0.1 kPa(gauge) [0.75 mmHg(gauge)]
2. EVAP pressure change during purge operation when vent valve closed Less than 0.4 kPa(gauge) [3 mmHg(gauge)]

MONITOR RESULT

CONFIRMATION DRIVING PATTERN

The vehicle has Evaporative System Check.
1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on.

6.

Start the engine and wait 15 minutes or more.

7.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

8.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



9.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

10.

Input the DTC: P0441.

11.

Check the DTC judgment result.

Techstream Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

You should perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the following procedure.



NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



12.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

13.

Turn the ignition switch off and wait for at least 30 seconds.

14.

Turn the ignition switch to ON and turn the Techstream on.

15.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

16.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

17.

Input the DTC: P0441.

18.

Check the DTC judgment result.

Techstream Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.



19.

If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.





The vehicle does not have Evaporative System Check.
A290275
0.573,1.146 1.313,1.333 0.74,0.188 10 64 km/h 0.75,1.771 1.667,1.969 0.917,0.198 10 Idling 0.177,2.073 1.156,2.427 0.979,0.354 10 Ignition Switch ON 2.198,1.625 2.656,1.823 0.458,0.198 10 [A] 3.313,1.625 3.771,1.823 0.458,0.198 10 [B] 4.917,0.896 5.375,1.094 0.458,0.198 10 [C] 6.375,3.052 6.833,3.25 0.458,0.198 10 [D] 1.906,2.604 2.771,2.792 0.865,0.188 10 Warming Up 2.76,2.615 4.01,2.792 1.25,0.177 10 10 minutes or more 4.583,2.615 5.688,2.813 1.104,0.198 10 5 to 10 minutes

1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on.

6.

Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [A].

7.

Idle the engine for 10 minutes or more [B].

8.

Drive the vehicle at 64 km/h (40 mph) for 5 to 10 minutes [C].

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.


9.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

10.

Read the pending DTCs [D].

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



11.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

12.

Input the DTC: P0441.

13.

Check the DTC judgment result.

Techstream Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform steps [B] through [D] again.



14.

If no pending DTC is output, perform a universal trip and check for permanent DTCs.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.





PROCEDURE

1.CHECK IF VEHICLE IS EQUIPPED WITH EVAPORATIVE SYSTEM CHECK
a.

Connect the Techstream to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the Techstream on.


d.

Enter the following menus: Powertrain / Engine and ECT / Utility.


e.

Check whether the vehicle is equipped with Evaporative System Check.

Result:
Result Proceed to
The vehicle does not have Evaporative System Check A
The vehicle has Evaporative System Check B




A

2.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV)

B

2.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV)
a.
A290286
1.854,3.073 1.063,2.531 false 2.385,2.521 1.875,2.063 false 2.417,2.49 2.729,2.688 0.313,0.198 10 *1 1.906,3.021 2.219,3.219 0.313,0.198 10 *2
*1 Purge VSV
*2 Fuel Vapor Feed Hose
(to Canister)


Disconnect the fuel vapor feed hose (connected to the canister) from the purge VSV.


b.

Connect the Techstream to the DLC3.


c.

Start the engine.


d.

Turn the Techstream on.


e.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Evap Control.

Powertrain > Engine and ECT > Active Test
Tester Display
Activate the VSV for Evap Control
50004 234 6

f.

Using the Techstream, turn off the purge VSV (Activate the VSV for Evap Control: OFF).


g.

Use your finger to confirm that the purge VSV has no suction.


h.

Using the Techstream, turn on the purge VSV (Activate the VSV for Evap Control: ON).


i.

Use your finger to confirm that the purge VSV has suction.

Result:
Result Proceed to
Suction when purge VSV turned on A
No suction when purge VSV turned on B




A

3.CHECK FUEL TANK CAP ASSEMBLY

B

10.CHECK EVAP PURGE LINE (PURGE VSV - INTAKE MANIFOLD)
3.CHECK FUEL TANK CAP ASSEMBLY
a.

Check that the fuel tank cap is correctly installed and confirm that the fuel tank cap meets OEM specifications.


b.

Tighten the fuel tank cap firmly (only one click sound could be heard).

OK:

A normal fuel tank cap assembly is properly installed.



HINT:

If an EVAP tester is available, check the fuel tank cap using the EVAP tester.

1.

Remove the fuel tank cap and install it onto a fuel tank cap adapter.

2.

Connect an EVAP tester pump hose to the adapter, and pressurize the cap to 3.2 to 3.7 kPa(gauge) [24 to 28 mmHg(gauge)] using an EVAP tester pump.

3.

Seal the adapter and wait for 2 minutes.

4.

Check the pressure. If the pressure is 2 kPa(gauge) [15 mmHg(gauge)] or more, the fuel tank cap is normal.



Result:
Result
OK
NG



OK

4.CHECK EVAP PURGE LINE (PURGE VSV - CHARCOAL CANISTER ASSEMBLY)

NG

REPLACE FUEL TANK CAP ASSEMBLY

4.CHECK EVAP PURGE LINE (PURGE VSV - CHARCOAL CANISTER ASSEMBLY)
a.

Check for blockages or leakages in the EVAP purge line between the purge VSV and canister.

OK:

No blockages and leakages in the EVAP purge line between the purge VSV and canister.



Result:
Result
OK
NG



OK

5.INSPECT CHARCOAL CANISTER ASSEMBLY (CHARCOAL FILTER INSIDE CANISTER)

NG

REPAIR OR REPLACE EVAP PURGE LINE (PURGE VSV - CANISTER ASSEMBLY)

5.INSPECT CHARCOAL CANISTER ASSEMBLY (CHARCOAL FILTER INSIDE CANISTER)
a.

Check for filter blockage in the canister.

Click hereEngine / Hybrid System>2AR-FE EMISSION CONTROL>CANISTER>INSPECTION

OK:

No blockages in the canister.



Result:
Result
OK
NG



OK

6.FOUND EVAP LEAK PART

NG

REPLACE CHARCOAL CANISTER ASSEMBLY

6.FOUND EVAP LEAK PART
a.

Disconnect the vent hose.


b.

Connect the EVAP pressure tester tool to the canister pump module with the adapter.

A290289
5.385,0.365 4.281,1.854 false 5.438,0.26 5.75,0.458 0.313,0.198 10 *1 1.229,4.917 1.542,5.115 0.313,0.198 10 *2 2.635,4.948 2.948,5.146 0.313,0.198 10 *3
*1 Canister Pump Module *2 EVAP Tester
*3 Adapter - -



c.

Pressurize the EVAP system to 3.2 to 3.7 kPa(gauge) [24 to 28 mmHg(gauge)].


d.

Apply soapy water to the piping and connecting parts of the EVAP system.


e.

Look for areas where bubbles appear. This indicates the leak point.

OK:

No leaks in EVAP system.


HINT:

Disconnect the hose between the canister and fuel tank from the canister. Block the canister side and conduct an inspection. In this way, the fuel tank can be excluded as an area suspected of causing fuel leaks.



Result:
Result
OK
NG



OK

7.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)

NG

REPAIR OR REPLACE EVAP LEAK PART

7.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
a.

Disconnect the canister pump module connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
V3-1 (VGND) - A62-7 (VPMP) Always Below 1 Ω
V3-5 (VLVB) - EFI-MAIN NO. 1 RELAY TERMINAL 3 Always Below 1 Ω
V3-1 (VGND) or A62-7 (VPMP) - Body ground Always 10 kΩ or higher
V3-5 (VLVB) or EFI-MAIN NO. 1 RELAY TERMINAL 3 - Body ground Always 10 kΩ or higher



Result:
Result
OK
NG



OK

8.REPLACE CHARCOAL CANISTER LEAK DETECTION PUMP SUB-ASSEMBLY (CANISTER PUMP MODULE)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.REPLACE CHARCOAL CANISTER LEAK DETECTION PUMP SUB-ASSEMBLY (CANISTER PUMP MODULE)
a.

Replace the charcoal canister leak detection pump sub-assembly.

Click hereEngine / Hybrid System>2AR-FE EMISSION CONTROL>CANISTER>REMOVAL

NOTICE:
·

When replacing the charcoal canister leak detection pump sub-assembly, check the canister pump module interior, canister interior and related pipes for water, fuel and other liquids. If liquids are present, check for disconnections and/or cracks in the following: 1) the pipe from the air inlet port to the canister pump module; 2) the canister filter; and 3) the fuel tank vent hose. If liquids are present in the canister interior, replace the canister and canister pump module together.

·

Check for filter blockage in the canister. If the charcoal filter inside the canister is clogged, replace the canister and canister pump module together.

·

Check for filter blockage in the canister filter. If the canister filter has blockages, replace the canister filter.



A290281
2.563,1.813 2.01,2.583 false 2.177,2.844 2.99,1.833 false 3.625,3.323 3.25,3.813 false 4.74,2.313 5.323,1.823 false 6.74,4.323 6.188,3.667 false 6.083,4.323 6.115,3.76 false 5.552,4.323 5.99,3.615 false 1,2.01 1.458,2.604 false 6.688,4.344 7,4.542 0.313,0.198 10 *3 3.042,1.75 3.354,1.948 0.313,0.198 10 *1 3.156,3.833 3.469,4.031 0.313,0.198 10 *2 5.365,1.729 5.677,1.927 0.313,0.198 10 *4 2.604,1.729 2.917,1.927 0.313,0.198 10 *5 0.802,1.927 1.115,2.125 0.313,0.198 10 *6 5.469,4.354 5.781,4.552 0.313,0.198 10 *7 3.885,1.115 4.198,1.313 0.313,0.198 10 *a 2.125,4.135 2.438,4.333 0.313,0.198 10 *a 6.01,4.344 6.323,4.542 0.313,0.198 10 *8
*1 Fuel Tank Vent Hose *2 Vent Hose
*3 Air Inlet Port *4 Fuel Tank
*5 Canister Pump Module *6 Canister Assembly
*7 Fuel Tank Inlet Pipe Sub-assembly (Canister Filter) *8 Fuel Tank Cap Assembly
*a Inspection Area (check for disconnection and/or cracks) - -



Result:
Proceed to
NEXT



NEXT

9.CHECK WHETHER DTC OUTPUT RECURS (AFTER REPAIR)
9.CHECK WHETHER DTC OUTPUT RECURS (AFTER REPAIR)
a.

Connect the Techstream to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the Techstream on.


d.

Clear the DTCs.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR

Powertrain > Engine and ECT > Clear DTCs
50002 234

e.

Turn the ignition switch off and wait for at least 30 seconds.


f.

Turn the ignition switch to ON.


g.

Turn the Techstream on.


h.

Start the engine and warm it up.


i.

Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.


j.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


k.

Read the DTCs.

Powertrain > Engine and ECT > Trouble Codes
50001 234
Result:
Result Proceed to
No DTC is output A
P0441 is output B




A

END

B

REPLACE ECM

10.CHECK EVAP PURGE LINE (PURGE VSV - INTAKE MANIFOLD)
a.

Check for blockages or leakages in the EVAP purge line between the purge VSV and intake manifold.

OK:

No blockages and leakages in the EVAP purge line between the purge VSV and intake manifold.



Result:
Result
OK
NG



OK

11.INSPECT PURGE VSV

NG

14.INSPECT INTAKE MANIFOLD (EVAP PURGE PORT)
11.INSPECT PURGE VSV

Result:
Result
OK
NG



OK

12.CHECK TERMINAL VOLTAGE (POWER SOURCE OF PURGE VSV)

NG

12.CHECK TERMINAL VOLTAGE (POWER SOURCE OF PURGE VSV)
a.
A161605
0.365,1.75 0.781,2.021 0.417,0.271 0.052,0 0.26,0.177 0.208,0.177 10 *a 0.479,1.802 0.708,1.948 0.229,0.146 10 B2
*a Front view of wire harness connector
(to Purge VSV)


Disconnect the purge VSV connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
B2-1 - Body ground Ignition switch ON 11 to 14 V



Result:
Result
OK
NG



OK

13.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (PURGE VSV - EFI-MAIN NO. 1 RELAY)

13.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM)
a.

Disconnect the purge VSV connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B2-2 - B77-68 (PRG) Always Below 1 Ω
B2-2 or B77-68 (PRG) - Body ground Always 10 kΩ or higher



Result:
Result
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

14.INSPECT INTAKE MANIFOLD (EVAP PURGE PORT)
a.

Disconnect the EVAP hose from the intake manifold.


b.

Start the engine and warm it up.


c.

Use your finger to confirm that the port of the intake manifold has suction.

Result:
Result Proceed to
Suction applied A
No suction B




A

REPAIR OR REPLACE EVAP PURGE LINE (PURGE VSV - INTAKE MANIFOLD)

B