The main body ECU (Multiplex Network Body ECU) receives a back door open or closed signal from back door courtesy light switch.
Using the Techstream, read the Data List.
Click hereVehicle Interior>LIGHTING (INT)>LIGHTING SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Back Door Courtesy SW | Back door courtesy light switch signal | ON or OFF | ON: Back door open
OFF: Back door closed |
- |
| Tester Display |
|---|
| Back Door Courtesy SW |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the back door lock assembly.
Click hereVehicle Interior>LIGHTING (INT)>BACK DOOR COURTESY SWITCH>REMOVAL
Inspect the back door lock assembly.
Click hereVehicle Interior>LIGHTING (INT)>BACK DOOR COURTESY SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the U12*1 or U13*2 back door lock assembly connector.
*1: w/o Power Back Door System
*2: w/ Power Back Door System
Disconnect the 3E instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| U12-3 (D+) - 3E-33 | Always | Below 1 Ω |
| U12-1 (ACT-) - Body ground | Always | Below 1 Ω |
| U12-3 (D+) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| U13-3 (CTY) - 3E-33 | Always | Below 1 Ω |
| U13-4 (E) - Body ground | Always | Below 1 Ω |
| U13-3 (CTY) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-20 (BCTY) - 3E-33 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG