The glow plug is mounted inside the engine combustion chamber. To ensure efficient engine starting with a cold engine, the ECM calculates a time interval of the current that needs to flow through the glow plug depending on the starting engine coolant temperature when the ignition switch is turned to ON. The ECM then turns on the glow plug relay and permits the current to flow through the glow plug based on the time calculated by the ECM. The glow plug is then heated, and enhances fuel combustion with a cold engine.
These troubleshooting procedures are for: 1) difficulty starting the engine in cold weather, and 2) difficulty driving/vehicle malfunctions in cold weather immediately after the engine is started.
After the engine is started, the ECM performs "after-glow" for a certain period of time. In proportion to the actual engine coolant temperature, the time period varies. The after-glow reduces diesel engine knocking, white smoke emissions and engine noises when the engine is cold.
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (Click here Engine / Hybrid System>2AD-FHV ENGINE CONTROL>ECD SYSTEM>REGISTRATION) and initialization (Click here Engine / Hybrid System>2AD-FHV ENGINE CONTROL>ECD SYSTEM>INITIALIZATION).
| *a | Front view of wire harness connector
(to Glow Plug Relay) |
Remove the glow plug relay assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B38-4 - Body ground | Always | 11 to 14 V |
Reinstall the glow plug relay assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the glow plug relay assembly.
Click hereEngine / Hybrid System>2AD-FHV STARTING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the glow plug assembly.
Click hereEngine / Hybrid System>2AD-FHV STARTING>GLOW PLUG>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the glow plug installation.
Click hereEngine / Hybrid System>2AD-FHV STARTING>GLOW PLUG>INSTALLATION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the glow plug relay assembly.
Disconnect the glow plug connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B38-3 - B83-1 | Always | Below 1 Ω |
| B38-1 - Body ground | Always | Below 1 Ω |
| B38-3 or B83-1 - Body ground | Always | 10 kΩ or higher |
Reinstall the glow plug relay assembly.
Reconnect the glow plug connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
Remove the glow plug relay assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B38-2 - B76-58 (GREL) | Always | Below 1 Ω |
| B38-2 or B76-58 (GREL) - Body ground | Always | 10 kΩ or higher |
Reinstall the glow plug relay assembly.
Reconnect the ECM connector.
OK
NG