While the engine is being cranked, the ECM receives the STA signal from the certification ECU (smart key ECU assembly), and then the ECM performs starting based on its signal.
Refer to DTC P0617.
Click hereEngine / Hybrid System>2WW ENGINE CONTROL>ECD SYSTEM>P0617
When replacing the ECM, the ECM needs registration and initialization.
Click hereEngine / Hybrid System>2WW ENGINE CONTROL>ECD SYSTEM>PRECAUTION
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the GTS. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the GTS display.
This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
| Tester Display |
|---|
| Starter Signal |
Check the value displayed on the GTS when the ignition switch is turned to the ON and START positions.
| Ignition Switch Position | Starter Signal |
|---|---|
| ON | OFF |
| START | ON |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Remove the starter relay (ST) from the engine room relay block and junction block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A62-36 (STA) - 2 (Starter relay (ST) holder) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG