Home › Engine / Hybrid System › 2WW ENGINE CONTROL › ECD SYSTEM › from 2015.10
RM3090E _51 Engine / Hybrid System _044372 2WW ENGINE CONTROL _0208480 ECD SYSTEM J

2WW ENGINE CONTROL  ECD SYSTEM  Cranking Holding Function Circuit  


DESCRIPTION

w/ Entry and Start System:

While the engine is being cranked, the ECM receives the STA signal from the certification ECU (smart key ECU assembly), and then the ECM performs starting based on its signal.


WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:
·

When replacing the ECM, the ECM needs registration and initialization.

Click hereEngine / Hybrid System>2WW ENGINE CONTROL>ECD SYSTEM>PRECAUTION

·

Inspect the fuses for circuits related to this system before performing the following inspection procedure.



HINT:
·

When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the GTS. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the GTS display.

·

This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table.



PROCEDURE

1.READ VALUE USING GTS (STARTER SIGNAL)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.

Powertrain > Engine and ECT > Data List
Tester Display
Starter Signal
50003 371 149

e.

Check the value displayed on the GTS when the ignition switch is turned to the ON and START positions.

OK:
Ignition Switch Position Starter Signal
ON OFF
START ON



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.CHECK HARNESS AND CONNECTOR (ECM - STARTER RELAY (ST))
2.CHECK HARNESS AND CONNECTOR (ECM - STARTER RELAY (ST))
a.

Disconnect the ECM connector.


b.

Remove the starter relay (ST) from the engine room relay block and junction block.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A62-36 (STA) - 2 (Starter relay (ST) holder) Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR