The MIL (Malfunction Indicator Lamp) is used to indicate vehicle malfunctions detected by the ECM. When the ignition switch is turned to ON, power is supplied to the MIL circuit, and the ECM provides the circuit ground, which illuminates the MIL.
The MIL operation can be checked visually. When the ignition switch is first turned to ON, the MIL should be illuminated and should then turn off when the engine is started. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the GTS.
When replacing the ECM, the ECM needs registration and initialization.
Click hereEngine / Hybrid System>2WW ENGINE CONTROL>ECD SYSTEM>PRECAUTION
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the GTS. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the GTS display.
Perform troubleshooting in accordance with the table below.
| Result | Proceed to |
|---|---|
| MIL remains on | A |
| MIL does not illuminate | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Check if DTCs have been stored. If DTCs are output, write them down.
Clear the DTCs.
Check that the MIL turns off.
MIL turns off.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Turn the ignition switch to ON.
Check that MIL is not illuminated.
MIL is not illuminated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-11 (CHK) or A62-59 (W) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-11 (CHK) - A62-59 (W) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG