HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1423/23  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored if refrigerant pressure on the high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more). The air conditioner pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory Note
B1423/23 Pressure Sensor Circuit
·

Open or short in air conditioner pressure sensor circuit

·

Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more)


·

Air conditioner pressure sensor

·

Harness or connector

·

Air conditioning amplifier assembly

·

Cooler expansion valve (blocked, stuck)

·

Condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Cooling fan system (condenser assembly cannot be cooled down)

·

Air conditioning system (leaks, blocked)


- -

HINT:

The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

E229252E35
2.229,1.969 2.323,2.146 0.094,0.177 10 false 1 2.229,1.021 2.323,1.198 0.094,0.177 10 false 2 4.854,1.021 4.948,1.198 0.094,0.177 10 false 9 4.771,1.969 4.948,2.146 0.177,0.177 10 false 13 1.885,1.115 2.229,1.417 0.344,0.302 10 false PR 0.885,3.927 3.052,4.333 2.167,0.406 10 false Air Conditioner Pressure Sensor 0.896,3.771 1.177,3.948 0.281,0.177 10 false A34 5.083,2.063 5.427,2.24 0.344,0.177 10 false SG-2 5.083,3.021 5.427,3.198 0.344,0.177 10 false S5-3 4.531,3.771 4.823,3.948 0.292,0.177 10 false G81 4.521,3.938 6.135,4.365 1.615,0.427 10 false Air Conditioning Amplifier Assembly 2.229,2.927 2.323,3.104 0.094,0.177 10 false 3 2,2.052 2.094,2.229 0.094,0.177 10 false - 2,3.021 2.104,3.198 0.104,0.177 10 false + 4.771,2.927 4.948,3.104 0.177,0.177 10 false 10 5.083,1.115 5.417,1.292 0.333,0.177 10 false PRE

CAUTION / NOTICE / HINT

NOTICE:

When the battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>INITIALIZATION


HINT:

If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B1423 first.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
E269957C01
1.5,0.26 1.927,0.51 0.427,0.25 2,1.177 2.479,1.177 false 1.594,0.313 2.052,0.51 0.458,0.198 10 A34 2.531,1.094 2.99,1.292 0.458,0.198 10 + 0.042,0.031 0.5,0.229 0.458,0.198 10 *a
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A34-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.
E269957C02
1.5,0.26 1.927,0.51 0.427,0.25 0.927,1.156 1.406,1.156 false 1.594,0.313 2.052,0.51 0.458,0.198 10 A34 0.813,1.073 1.271,1.271 0.458,0.198 10 - 0.042,0.031 0.5,0.229 0.458,0.198 10 *a
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the A34 air conditioner pressure sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-1 (-) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.
E227427C23
1.281,0.292 1.74,0.573 0.458,0.281 1.563,1.01 0.927,1.531 false 0.177,0.167 0.625,0.521 0.448,0.354 10 *a 0.76,1.552 1.313,1.875 0.552,0.323 10 PRE 1.396,0.354 2.156,0.875 0.76,0.521 10 G81
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Remove the air conditioning amplifier assembly with the connectors still connected.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
G81-9 (PRE) - Body ground Ignition switch ON
A/C switch off
0.62 to 4.73 V


HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



Result:
Proceed to
OK
NG



OK

4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 2000 rpm

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
E227427C25
1.26,0.313 1.719,0.594 0.458,0.281 1.573,1.01 1.01,1.51 false 0.167,0.146 0.771,0.656 0.604,0.51 10 *a 0.833,1.521 1.729,2.052 0.896,0.531 10 PRE 1.396,0.365 1.844,0.542 0.448,0.177 10 G81
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
G81-9 (PRE) - Body ground Ignition switch ON
A/C switch on
0.62 to 4.73 V




Result:
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

13.CHECK COOLING FAN SYSTEM
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the G81 air conditioning amplifier assembly connector.


b.

Disconnect the A34 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-3 (+) - G81-10 (S5-3) Always Below 1 Ω
G81-10 (S5-3) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the G81 air conditioning amplifier assembly connector.


b.

Disconnect the A34 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-1 (-) - G81-13 (SG-2) Always Below 1 Ω
G81-13 (SG-2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the G81 air conditioning amplifier assembly connector.


b.

Disconnect the A34 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A34-2 (PR) - G81-9 (PRE) Always Below 1 Ω
G81-9 (PRE) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

8.CHECK FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK FOR AIR CONDITIONING SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.


c.

Evacuate the air conditioning system and check that vacuum can be maintained in it.

HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.


OK:

Vacuum can be maintained in the air conditioning system.



Result:
Proceed to
OK
NG



OK

9.CHARGE SYSTEM WITH REFRIGERANT

NG

11.REPAIR AIR CONDITIONING SYSTEM LEAK
9.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.


HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTC.



Result:
Proceed to
NEXT



NEXT

10.CHECK FOR DTC
10.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 2000 rpm

NOTICE:
·

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.

·

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.



HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


OK:

DTC B1423/23 is not output.



Result:
Proceed to
OK
NG



OK

END

NG

12.CHECK AIR CONDITIONER PRESSURE SENSOR
11.REPAIR AIR CONDITIONING SYSTEM LEAK

b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.


Result:
Proceed to
NEXT



NEXT

12.CHECK AIR CONDITIONER PRESSURE SENSOR
a.

Install a manifold gauge set.


b.

Turn the ignition switch to ON.


c.
E227427C24
1.26,0.313 1.646,0.563 0.385,0.25 1.573,1.01 1.969,1.604 false 1.333,1.01 0.938,1.604 false 0.177,0.167 0.333,0.313 0.156,0.146 10 *a 1.854,1.635 2.302,1.917 0.448,0.281 10 PRE 0.719,1.635 1.115,1.781 0.396,0.146 10 SG-2 1.344,0.344 1.646,0.5 0.302,0.156 10 G81
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
G81-9 (PRE) - G81-13 (SG-2) Engine running
Air conditioning system operating
Refrigerant pressure:(below 3025 kPa [30.8 kgf/cm2, 439 psi] and higher than 176 kPa [1.8 kgf/cm2, 26 psi])
0.62 to 4.73 V



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

13.CHECK COOLING FAN SYSTEM

OK

14.CHARGE SYSTEM WITH REFRIGERANT

NG

14.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.


HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTC.



Result:
Proceed to
NEXT



NEXT

15.CHECK FOR DTC
15.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 2000 rpm

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.



OK:

DTC B1423/23 is not output.



Result:
Proceed to
OK
NG



OK

NG

16.REPLACE COOLER EXPANSION VALVE
16.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a new one.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL

HINT:

Replace the cooler expansion valve with a new one because the expansion valve is either stuck or clogged.



Result:
Proceed to
NEXT



NEXT

17.CHARGE SYSTEM WITH REFRIGERANT
17.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant.


HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for DTC.



Result:
Proceed to
NEXT



NEXT

18.CHECK FOR DTC
18.CHECK FOR DTC
a.

Check for DTCs when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed Hi
A/C Switch On
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 2000 rpm

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a normal one, the condenser or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the condenser or pipes.



OK:

DTC B1423/23 is not output.



Result:
Proceed to
OK
NG



OK

END (COOLER EXPANSION VALVE IS DEFECTIVE)

NG

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY