If there is a difference in temperature between the left and right air outlets while dual mode is ON, the following causes are possible.
| Malfunction Status | Factor |
|---|---|
| There is a difference in temperature between the left and right air outlets (while cooling operation) | ·
Compressor with pulley assembly malfunction ·
Lack of refrigerant gas ·
Air mix damper and link operation (jamming) ·
Automatic light control sensor malfunction |
| There is a difference in temperature between the left and right air outlets (while heater operation) | ·
Air mix damper and link operation (jamming) ·
Heater core closed waterway |
If DTC B1244 is output, troubleshoot for DTC B1244 first.
Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>B1244
Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.
| Result | Proceed to |
|---|---|
| While cooling | A |
| While heater | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
"Refrigerant correct" is displayed on GTS.
Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine running |
| A/C Switch | On |
| Ambient Temperature*1 | 0 to 49°C (32 to 120°F) |
| Air Conditioning Air Inlet Temperature*2 | 25 to 35°C (77 to 95°F) |
| Set Temperature | MAX COLD |
| Recirculation/fresh Control Switch | Recirculation |
| Air Vent Damper Position | FACE |
| Blower Speed | HI |
Refer to the GTS operator's manual for further details.
A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant shortage check using the GTS.
*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
| Result | Amount of Refrigerant |
|---|---|
| Refrigerant shortage | Insufficient or leakage |
| Refrigerant correct | Correct |
"Refrigerant correct" is displayed on the GTS.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for HFO-1234yf (R1234yf):Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFO-1234yf(R1234yf))>REPLACEMENT
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H1 automatic light control sensor connector.
Disconnect the G44 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H1-1 (CLTB) - G44-23 (CLTB) | Always | Below 1 Ω |
| H1-2 (CLTE) - G44-25 (CLTE) | Always | Below 1 Ω |
| H1-4 (CLTS) - G44-24 (CLTS) | Always | Below 1 Ω |
| H1-1 (CLTB) or G44-23 (CLTB) - Other terminals and body ground | Always | 10 kΩ or higher |
| H1-2 (CLTE) or G44-25 (CLTE) - Other terminals and body ground | Always | 10 kΩ or higher |
| H1-4 (CLTS) or G44-24 (CLTS) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the automatic light control sensor.
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>REMOVAL
Inspect the automatic light control sensor.
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Check that there is not a difference in temperature between the left and right air outlets.
There is not a difference in temperature between the left and right air outlets.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
| Proceed to |
|---|
| OK |
| NG |
OK
NG