Refer to DTC P091412.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>P091412
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P091414 | Gear Shift Position Circuit Short to Ground or Open | A short to ground or open is detected in the shift stroke sensor circuit for 5 seconds or more (1-trip detection logic). | ·
Shift stroke sensor ·
Harness and connector ·
TCM |
Comes on | DTC stored | SAE Code:
P0916 |
This DTC indicates an open or short to ground in the shift stroke sensor circuit. If there is an open or short to ground in the shift stroke sensor circuit, the TCM detects the malfunction, illuminates the MIL and stores this DTC.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the GTS on.
Start the engine.
Perform the D Position Test inspection in Road Test.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>ROAD TEST
Stop the vehicle.
Enter the following menus: Powertrain / Transmission / Utility / All Readiness.
Input the DTC: P091414.
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| N/A | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the Confirmation Driving Pattern and check the DTC judgment result again.
Refer to DTC P091412.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>P091412
Perform registration and/or initialization when parts related to the continuously variable transaxle system are replaced.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>PRECAUTION
Check that no DTCs are stored after performing initialization.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>DTC CHECK / CLEAR
| *a | Front view of wire harness connector
(to Shift Stroke Sensor) |
Disconnect the shift stroke sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C39-2 (VDD) - C39-3 (GND) | Ignition switch ON | 4.7 to 5.3 V |
Connect the shift stroke sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C39 shift stroke sensor connector.
Disconnect the C33 TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C39-4 (VOUT) - C33-46 (SFV) | Always | Below 1 Ω |
| C39-4 (VOUT) or C33-46 (SFV) - Body ground and other terminals | Always | 10 kΩ or higher |
Connect the C33 TCM connector.
Connect the C39 shift stroke sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect 3 new dry-cell batteries (1.5 V each) in series.
Prepare a magnet or equivalent tool.
Remove the shift stroke sensor.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>SHIFT STROKE SENSOR>REMOVAL
Connect a positive (+) lead from the batteries to terminal 2 (VDD) and a negative (-) lead to terminal 3 (GND).
| *a | Component without harness connected
(Shift Stroke Sensor) |
*b | Magnet Movement Direction |
| *c | Dry Cell Battery | *d | Magnet |
| *e | 2.6 mm or less | - | - |
Wave the magnet left and right 2.6 mm (0.102 in.) or less from the tip of the shift stroke sensor to output a high/low signal while measuring the voltage.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (VOUT) - 3 (GND) | High signal | 4.09 to 4.19 V |
| Low signal | 0.36 to 0.45 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (VOUT) - 3 (GND) | High signal | 4.55 to 4.65 V |
| Low signal | 0.4 to 0.5 V |
Install the shift stroke sensor.
Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>SHIFT STROKE SENSOR>INSTALLATION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the TCM.
| Proceed to |
|---|
| NEXT |
NEXT
for Registration: Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>REGISTRATION
for Initialization: Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION
Disconnect the C39 shift stroke sensor connector.
Disconnect the C33 TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C39-2 (VDD) - C33-45 (VCSF) | Always | Below 1 Ω |
| C39-3 (GND) - C33-44 (E2SF) | Always | Below 1 Ω |
| C39-2 (VDD) or C33-45 (VCSF) - Body ground and other terminals | Always | 10 kΩ or higher |
| C39-3 (GND) or C33-44 (E2SF) - Body ground and other terminals | Always | 10 kΩ or higher |
Connect the C33 TCM connector.
Connect the C39 shift stroke sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the TCM.
| Proceed to |
|---|
| NEXT |
NEXT
for Registration: Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>REGISTRATION
for Initialization: Click hereDrivetrain>K120F (MULTIDRIVE / CVT)>CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM>INITIALIZATION