The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during brake pedal stroke sensor assembly removal/installation are shown below.
After the power switch is turned off, the radio receiver assembly records various types of memory and settings. As a result, after turning the power switch off, make sure to wait at least 85 seconds before disconnecting the cable from the negative (-) auxiliary battery terminal.
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.
2.DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
Click hereGeneral>MAINTENANCE>A25A-FXS AUXILIARY BATTERY>REMOVAL
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
If the airbag deploys for any reason, it may cause a serious accident.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION
67914B
3.REMOVE FRONT DOOR SCUFF PLATE LH
62112
4.REMOVE COWL SIDE TRIM BOARD LH
55606
5.REMOVE NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
89510D
6.REMOVE BRAKE PEDAL STROKE SENSOR ASSEMBLY
Disconnect the connector from the brake pedal stroke sensor assembly.
Remove the 2 nuts and brake pedal stroke sensor assembly from the brake pedal support assembly.
Do not drop the brake pedal stroke sensor assembly.
If the brake pedal stroke sensor assembly has been dropped, replace the brake pedal stroke sensor assembly with a new one.