The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1497 | Communication Malfunction (Bus Ic) | ·
Diagnosis condition: None ·
Malfunction status: Error or open in communication line between air conditioning amplifier assembly and servo motor |
·
Air conditioning harness assembly ·
No. 1 air conditioning radiator damper servo sub-assembly ·
No. 2 air conditioning radiator damper servo sub-assembly ·
No. 3 air conditioning radiator damper servo sub-assembly (w/ Driver Seat Centralized Control) ·
No. 1 blower damper servo sub-assembly ·
Air conditioning amplifier assembly |
Memorized |
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 164 to 278 pulses for RHD:
Operates between 234 to 348 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
for Double Layer Type:
Operates between 220 to 256 pulses for Single Layer Type:
Operates between 235 to 258 pulses |
| Air Outlet Servo Pulse (P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 234 to 348 pulses for RHD:
Operates between 164 to 278 pulses (w/ Driver Seat Centralized Control) |
| A/O Servo Pulse(Rr D) | No. 2 air conditioning radiator damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 158 to 260 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Air Outlet Servo Pulse (D) |
| Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
| Tester Display |
|---|
| Air Outlet Servo Pulse (P) |
| Tester Display |
|---|
| A/O Servo Pulse(Rr D) |
Damper servo motor is operated.
Check the operation by referring to the table below.
| Result | Proceed to |
|---|---|
| All damper servo motors are not operated | A |
| Any damper servo motor is not operated | B |
| All damper servo motors are operated | C |
A
B
C
| *a | Component without harness connected
(Air Conditioning Amplifier Assembly) |
Disconnect the air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (BUS G) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 2 (BUS G) - 3 (BUS) | Power switch on (IG) | 11 to 14 V |
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Tester Connection | 2 (BUS G) - 3 (BUS) |
| Tool Setting | 2 V/DIV., 20 μs/DIV. |
| Condition | Power switch on (IG) |
The waveform displays properly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG