Home › Engine / Hybrid System › A25A-FKS (COOLING) › FLOW SHUTTING VALVE(for Heater) › from 2020.08
RM3620E _51 Engine / Hybrid System _076659 A25A-FKS COOLING _0373122 FLOW SHUTTING VALVE(for Heater) A

A25A-FKS COOLING  FLOW SHUTTING VALVE(for Heater)  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water by-pass hose assembly) removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link

*: When performing learning using the GTS.

Click here(Click here)

Battery terminal is disconnected/reconnected Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes) Stop and start system (Click here)
Perform steering sensor zero point calibration Lane control system (Click here)
Parking support brake system (for Gasoline model)*
Pre-collision system
Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (for Gasoline Model) (Click here)
Reset back door close position Power back door system (for Gasoline model) (Click here)
Power back door initialization Power door lock control system (Click here)
Replacement of ECM Perform Vehicle Identification Number (VIN) or frame number registration DTC P063051 is output w/ Canister Pump Module:(Click here)
w/o Canister Pump Module:(Click here)
ECU communication ID registration Engine start function See Service Bulletin for the registration method.
for UB80E:

If transaxle compensation code read from ECM

-

Perform reset memory

-

Transfer transaxle compensation code

-

Perform road test to allow ECM to learn



·

Large shift shock

·

Deterioration of fuel efficiency


for Initialization:(Click here)
for Registration:(Click here)
for UB80E:

If transaxle compensation code not read from ECM

-

Perform reset memory

-

Reset transaxle compensation code

-

Perform road test to allow ECM to learn



for UB80F:

If transaxle compensation code read from ECM

-

Perform reset memory

-

Transfer transaxle compensation code

-

Perform road test to allow ECM to learn



·

Large shift shock

·

Deterioration of fuel efficiency


for Initialization:(Click here)
for Registration:(Click here)
for UB80F:

If transaxle compensation code not read from ECM

-

Perform reset memory

-

Reset transaxle compensation code

-

Perform road test to allow ECM to learn




NOTICE:

After the ignition switch is turned off, the navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the ignition switch off, wait a minute or more before disconnecting the cable from the negative (-) battery terminal.


PROCEDURE

Hide 16261G 1.REMOVE FLOW SHUTTING VALVE (NO. 1 WATER BY-PASS HOSE)

Hide 16260 2.REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

a.
A434864

Detach the 2 clamps and disconnect the vacuum hose from the engine wire harness.


b.
A434865

Disconnect the 3 connectors.


c.

Detach the clamp and disconnect the engine wire harness from the water hose clamp bracket.


d.

Disconnect the outlet heater hose connector from the No. 2 water by-pass pipe sub-assembly.

NOTICE:

Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater hose connector before performing this work.


i.
A434866C01
1.979,1.292 2.198,1.531 2.198,1.531 2.385,1.531 true 2.427,1.427 2.667,1.635 0.24,0.208 10 true *a
*a Retainer
V100135

Pull out
V100136

Pull off


Pull out the retainer to detach the lock claws and pull off the outlet heater hose connector.


ii.

Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.


iii.

Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater hose connector with plastic bags to prevent damage and contamination.



e.

Disconnect the inlet heater hose connector from the flow shutting valve (water by-pass hose assembly).

NOTICE:

Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector before performing this work.


i.
A434867C01
1,1.49 1.188,1.49 1.188,1.49 1.573,1.115 true 0.719,1.396 0.979,1.604 0.26,0.208 10 true *a
*a Retainer
V100135

Pull out
V100136

Pull off


Pull out the retainer to detach the lock claws and pull off the inlet heater hose connector.


ii.

Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.


iii.

Cover the disconnected inlet heater hose connector with a plastic bag to prevent damage and contamination.



f.
A434868

Remove the bolt to disconnect the No. 2 water by-pass pipe sub-assembly.


g.
A434869

Remove the bolt to disconnect the flow shutting valve (water by-pass hose assembly).


h.
A434870

Detach the 2 clamps and disconnect the wire harness.


i.
A434871

Remove the 2 bolts and the water hose clamp bracket.


j.
A434872

Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the water by-pass outlet sub-assembly.

HINT:

Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and water by-pass outlet sub-assembly.



k.
A434873

Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the transmission oil cooler.

HINT:

Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and transmission oil cooler.