The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water by-pass hose assembly) removal/installation are shown below.
After the ignition switch is turned off, the navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the ignition switch off, wait a minute or more before disconnecting the cable from the negative (-) battery terminal.
1.REMOVE BATTERY
53895B
2.REMOVE FRONT FENDER FRONT SPLASH SHIELD RH
53896B
3.REMOVE FRONT FENDER FRONT SPLASH SHIELD LH
51441
4.REMOVE NO. 1 ENGINE UNDER COVER
51420
5.REMOVE NO. 2 ENGINE UNDER COVER ASSEMBLY
6.DRAIN ENGINE COOLANT
16260
7.REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
| *A | for CVT |
| *B | for Manual Transaxle |
Disconnect the flow shutting valve (water by-pass hose assembly) connector.
Disconnect the inlet heater water hose connector from the flow shutting valve (water by-pass hose assembly).
Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater water hose connector before performing this work.
| *A | for CVT |
| *B | for Manual Transaxle |
| *a | Retainer |
|
Pull out |
|
Pull off |
Pull out the retainer to detach the lock claws and pull off the inlet heater water hose connector.
Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
Cover the disconnected inlet heater water hose connector with a plastic bag to prevent damage and contamination.
Disconnect the outlet heater water hose connector from the No. 2 water by-pass pipe sub-assembly.
Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater water hose connector before performing this work.
| *A | for CVT |
| *B | for Manual Transaxle |
| *a | Retainer |
|
Pull out |
|
Pull off |
Pull out the retainer to detach the lock claws and pull off the outlet heater water hose connector.
Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater water hose connector with plastic bags to prevent damage and contamination.
| *A | for CVT |
| *B | for Manual Transaxle |
Remove the bolt to disconnect the No. 2 water by-pass pipe sub-assembly.
| *A | for CVT |
| *B | for Manual Transaxle |
Remove the bolt to disconnect the flow shutting valve (water by-pass hose assembly).
| *A | for CVT |
| *B | for Manual Transaxle |
Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the water by-pass outlet sub-assembly.
Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and water by-pass outlet sub-assembly.