DTC B181A/7A Short in Passenger Side Airbag Variable Vent Hole Squib Circuit |
DTC B181B/7A Open in Passenger Side Airbag Variable Vent Hole Squib Circuit |
DTC B181C/7A Short to GND in Passenger Side Airbag Variable Vent Hole Squib Circuit |
DTC B181D/7A Short to B+ in Passenger Side Airbag Variable Vent Hole Squib Circuit |
| DTC Code | Detection Condition | Trouble Area |
| B181A/7A | When one of the following conditions is met:
|
|
| B181B/7A | When one of the following conditions is met:
|
|
| B181C/7A | When one of the following conditions is met:
|
|
| B181D/7A | When one of the following conditions is met:
|
|

| 1.CHECK FRONT PASSENGER AIRBAG (VARIABLE VENT HOLE SQUIB) |
![]() |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the front passenger airbag.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector E (orange connector).
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector E.
Check that the instrument panel wire connectors (on the front passenger airbag side) are not damaged.
|
| ||||
| OK | |
| 3.CHECK VARIABLE VENT HOLE SQUIB CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| z14-1 (P2+) - Body ground | Ignition switch ON | Below 1 V |
| z14-2 (P2-) - Body ground |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z14-1 (P2+) - z14-2 (P2-) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| z14-1 (P2+) - z14-2 (P2-) | Always | 1 MΩ or higher |
| z14-1 (P2+) - Body ground | ||
| z14-2 (P2-) - Body ground |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR |
Restore the released activation prevention mechanism of connector B to the original condition.
![]() |
Connect the connectors to the front passenger airbag and center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 5.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR - NO. 2 INSTRUMENT PANEL WIRE ASSEMBLY) |
![]() |
Restore the released activation prevention mechanism of connector B to the original condition.
Disconnect the instrument panel wire connector from the No. 2 instrument panel wire assembly.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Hz2-1 - Body ground | Ignition switch ON | Below 1 V |
| Hz2-2 - Body ground |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Hz2-1 - Hz2-2 | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Hz2-1 - Hz2-2 | Always | 1 MΩ or higher |
| Hz2-1 - Body ground | ||
| Hz2-2 - Body ground |
|
| ||||