HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  B1423/23  Pressure Sensor Circuit  


DESCRIPTION

This DTC is output when refrigerant pressure on the high pressure side is extremely low (196 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3138 kPa (32 kgf/cm2, 455 psi) or more). The pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the air conditioning amplifier. The air conditioning amplifier converts this signal to pressure according to the sensor characteristics to control the compressor.

DTC Code DTC Detection Condition Trouble Area
B1423/23
·

Open or short in pressure sensor circuit

·

Refrigerant pressure on the high pressure side is extremely low (196 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3138 kPa (32 kgf/cm2, 455 psi) or more).


·

Air conditioning pressure sensor

·

Harness or connector between air conditioning pressure sensor and air conditioning amplifier

·

Air conditioning amplifier

·

A/C system (leaks, blocked)



WIRING DIAGRAM

E345202E01
0.844,2 1.302,2.198 0.458,0.198 10 false A22 0.802,2.177 5.698,2.375 4.896,0.198 10 false Air Conditioning Pressure Sensor 4.948,1.979 5.406,2.177 0.458,0.198 10 false H24 4.917,2.156 6.542,2.448 1.625,0.292 10 false Air Conditioning Amplifier 0.771,1.26 0.917,1.458 0.146,0.198 10 false 1 1.073,1.365 1.229,1.563 0.156,0.198 10 false - 2.5,0.823 2.656,1.021 0.156,0.198 10 false + 2.76,0.708 2.917,0.906 0.156,0.198 10 false 3 2.771,1.292 2.927,1.49 0.156,0.198 10 false 2 2.396,1.427 2.708,1.625 0.313,0.198 10 false PR 4.677,0.719 4.938,0.917 0.26,0.198 10 false 10 4.74,1.313 4.958,1.521 0.219,0.208 10 false 9 4.99,0.823 5.604,1.021 0.615,0.198 10 false S5-3 5,1.427 5.615,1.625 0.615,0.198 10 false PRE

PROCEDURE

1.CHECK REFRIGERANT PRESSURE

b.

Read the manifold gauge pressure when the following conditions are established.

i.

Prepare the vehicle in accordance with the chart below.

Item Condition
Engine speed 1500 rpm
Vehicle doors Fully open
Temperature setting MAX COLD
Blower speed HI
A/C switch ON
Air inlet RECIRC


ii.

When the refrigerant volume is correct, the gauge reading indicates as follows:

Standard:
Refrigerant Pressure Specified Condition
Low pressure side 147 to 245 kPa (1.5 to 2.5 kgf/cm2, 21 to 36 psi)
High pressure side 1372 to 1569 kPa (14 to 16 kgf/cm2, 199 to 228 psi)


HINT:

Pressure varies in accordance with certain conditions (outside air temperature, sunlight and wind).





OK

2.READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR)

NG

5.CHECK FOR A/C SYSTEM LEAK
2.READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR)
a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the Techstream to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the Techstream on.


f.

Enter the following menus: Body Electrical / Air Conditioner / Data List / Regulator Pressure Sensor.


g.

According to the display on the Techstream, read the Data List.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Regulator pressure sensor /
Min: -0.45668 MPaG
Max: 3.29437 MPaG
Actual refrigerant pressure is displayed -


OK:

The display is as specified in the normal condition.


Result
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC output) C


A

3.INSPECT AIR CONDITIONING PRESSURE SENSOR

B

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C

3.INSPECT AIR CONDITIONING PRESSURE SENSOR

b.

Disconnect the A22 air conditioning pressure sensor connector.


c.

Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3, and the negative (-) lead to terminal 1.


d.

Connect the voltmeter positive (+) lead to terminal 2, and the negative (-) lead to terminal 1.


E345203E01
1.458,1.531 0.771,0.938 0.771,0.938 0.573,0.938 true 1.281,1.531 0.792,1.333 0.792,1.333 0.573,1.333 true 1.135,1.552 0.792,1.76 0.792,1.76 0.573,1.76 true 0.417,0.125 2.875,0.615 2.458,0.49 10 false Component without harness connected: (Air Conditioning Pressure Sensor) 0.385,0.833 0.542,1.031 0.156,0.198 10 false 1 0.385,1.25 0.542,1.448 0.156,0.198 10 false 2 0.385,1.656 0.542,1.854 0.156,0.198 10 false 3 4.333,0.135 6.021,0.333 1.688,0.198 10 false (V) Voltage 4.177,0.417 4.635,0.615 0.458,0.198 10 false 4.9 4.177,0.573 4.635,0.771 0.458,0.198 10 false 4.8 4.188,1.49 4.646,1.688 0.458,0.198 10 false 1.0 4.198,1.74 4.656,1.938 0.458,0.198 10 false 0.5 4.198,1.896 4.656,2.094 0.458,0.198 10 false 0.1 4.74,2.115 4.896,2.313 0.156,0.198 10 false 0 4.938,2.115 5.25,2.792 0.313,0.677 10 false 392 (4) (57) 5.781,2.115 6.146,2.792 0.365,0.677 10 false 3187 (32.5) (463) 6.417,2.125 7.063,2.646 0.646,0.521 10 false kPa (kgf/cm2) (psi) 3.323,2.365 6.385,2.563 3.063,0.198 10 false Refrigerant Pressure

e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1 - 2 Refrigerant pressure:
392 to 3187 kPa (4 to 32.5 kgf/cm2, 57 to 463 psi)
1.0 to 4.8 V



f.

Reconnect the air conditioning pressure sensor connector.



OK

4.CHECK HARNESS AND CONNECTOR (A/C PRESSURE SENSOR - A/C AMPLIFIER, BODY GROUND)

NG

4.CHECK HARNESS AND CONNECTOR (A/C PRESSURE SENSOR - A/C AMPLIFIER, BODY GROUND)
a.
E345204E01
0.51,0.99 0.896,1.219 0.385,0.229 1.646,2.833 2.01,3.063 0.365,0.229 0.979,1.583 1.49,1.208 true 1.427,1.771 1.708,1.24 true 2.479,1.615 2.021,1.24 true 1.677,4.302 1.958,3.896 true 2.344,4.302 2.031,3.885 true 0.615,0.083 2.938,0.583 2.323,0.5 10 false Front view of wire harness connector: (to Air Conditioning Pressure Sensor) 0.583,1.021 1.042,1.219 0.458,0.198 10 false A22 0.594,2.063 2.844,2.531 2.25,0.469 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier) 0.813,1.552 1.271,1.75 0.458,0.198 10 false (-) 1.333,1.771 1.792,1.969 0.458,0.198 10 false PR 2.521,1.563 2.979,1.76 0.458,0.198 10 false (+) 1.521,4.313 2.135,4.51 0.615,0.198 10 false S5-3 2.313,4.323 2.927,4.521 0.615,0.198 10 false PRE 1.698,2.875 1.979,3.052 0.281,0.177 10 true H24

Disconnect the A22 air conditioning pressure sensor connector.


b.

Disconnect the H24 air conditioning amplifier connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A22-1 (-) - Body ground Always Below 1 Ω
A22-2 (PR) - H24-9 (PRE) Always Below 1 Ω
A22-3 (+) - H24-10 (S5-3) Always Below 1 Ω
A22-2 (PR) - Body ground Always 10 kΩ or higher
A22-3 (+) - Body ground Always 10 kΩ or higher



d.

Reconnect the air conditioning amplifier connector.


e.

Reconnect the A/C pressure sensor connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK FOR A/C SYSTEM LEAK

b.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.


c.

Evacuate the A/C system and check that vacuum can be maintained in it.

OK:

Vacuum can be maintained in the A/C system.


HINT:

If vacuum cannot be maintained in the A/C system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the A/C system.




OK

6.CHARGE REFRIGERANT

NG

8.REPAIR A/C SYSTEM LEAK
6.CHARGE REFRIGERANT
a.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).



NEXT

7.RECHECK DTC
7.RECHECK DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F) or higher
Engine Speed 2000 rpm

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the A/C operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


NOTICE:

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.



Result
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B


A

B

END

8.REPAIR A/C SYSTEM LEAK
a.

Identify the area where refrigerant leaks from (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).


b.

Repair the identified area of the A/C system.


c.

Evacuate the A/C system.



NEXT

9.CHARGE REFRIGERANT
9.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system may freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant, properly evacuate the system, add an appropriate amount of refrigerant, and check for the DTC.




NEXT

10.RECHECK DTC
10.RECHECK DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F) or higher
Engine Speed 2000 rpm

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be set. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be set after the A/C operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system may freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant, properly evacuate the system, add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair it is necessary to replace the cooler dryer.




Result
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B


A

B

END