Refer to P2440 (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>P2440).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2444
P2446 |
Secondary air pressure more than 2.4 kPa (18 mmHg) despite ECM commanding air pump to turn off
(2 trip detection logic) |
·
Short in air pump circuit ·
Open or short in pressure sensor circuit ·
Air switching valve assembly (Pressure sensor) ·
Air Injection Control Driver (AID) ·
ECM |
| P2445
P2447 |
Secondary air pressure less than 2.4 kPa (18 mmHg) despite ECM commanding air pump to turn on
(2 trip detection logic) |
·
Air pump ·
Open in air pump circuit ·
Air injection system piping ·
Vacuum hose (pressure sensor - air switching valve) ·
Air switching valve assembly (Pressure sensor) ·
Open or short in pressure sensor circuit ·
Air Injection Control Driver (AID) ·
ECM ·
Open or short in air pump heater circuit ·
Air pump heater relay (AI-HTR) |
| When secondary air injection is on, the amount of air from the air pump is below the threshold (2 trip detection logic). |
The ECM monitors the pressure in the secondary air passage using the pressure sensor located on the Air Switching Valve (ASV) of the Secondary Air Injection (AIR) system. The sensor measures the pressure in the secondary air passage and transmits a signal to the ECM.
If either of the following conditions occurs, the ECM interprets it as a malfunction of the AIR system, and illuminates the MIL and stores a DTC:
The pressure indicated by the pressure sensor does not reach threshold levels despite the ECM turning on the air pump.
The pressure indicated by the pressure sensor exceeds threshold levels despite the ECM turning off the air pump.
| Related DTCs | P2444: Air pump stuck ON
P2445: Air pump stuck OFF P2446: Air pump stuck ON P2447: Air pump stuck OFF |
| Required Sensors/Components (Main) | Pressure sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Once per drive cycle |
| Duration | 7 seconds |
| MIL Operation | 2 driving cycles |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not stored | P0010, P0020 (Camshaft Timing Oil Control Valve)
P0011, P0021 (VVT System - Advance) P0012, P0022 (VVT System - Retard) P0016, P0018 (VVT System - Misalignment) P0013, P0023 (Exhaust Camshaft Timing Oil Control Valve) P0014, P0024 (Exhaust VVT System - Advance) P0015, P0025 (Exhaust VVT System - Retard) P0017, P0019 (Exhaust VVT System - Misalignment) P0031, P0032, P0051, P0052, P101D, P103D (Air Fuel Ratio Sensor Heater) P014C, P014D, P014E, P014F, P015A, P015B, P015C, P015D, P2195, P2196, P2197, P2198, P2237, P2238, P2239, P2240, P2241, P2242, P2252, P2253, P2255, P2256 (Air Fuel Ratio Sensor) P0102, P0103 (Mass Air Flow Meter) P0112, P0113 (Intake Air Temperature Sensor) P0115, P0117, P0118 (Engine Coolant Temperature Sensor) P0125 (Insufficient Coolant Temperature for Closed Loop Fuel Control) P0120, P0121, P0122, P0123, P0220, P0222, P0223, P2135 (Throttle Position Sensor) P0171, P0172, P0174, P0175 (Fuel System) P0300 - P0308 (Misfire) P0327, P0328, P0332, P0333, P032C, P032D, P033C, P033D (Knock Sensor) P0335 (Crankshaft Position Sensor) P1340 (Camshaft Position Sensor) P0340, P0342, P0343, P0345, P0347, P0348 (VVT Sensor) P0365, P0367, P0368, P0390, P0392, P0393 (Exhaust VVT Sensor) P0351 - P0358 (Igniter) P0451, P0452, P0453 (EVAP System) P0500, P0722 (Vehicle Speed Sensor) P106B (Evap. emission control system pressure sensor - Air injection system pressure sensor correlation) P219A, P219B, P219C, P219D, P219E, P219F, P21A0, P21A1, P21A2, P21A3 (Air-fuel ratio imbalance) P2431, P2432, P2433, P2436, P2437, P2438 (Secondary Air Injection System Pressure Sensor) |
| Battery voltage | 11 V or higher |
| Atmospheric pressure | 45 kPa (337.5 mmHg) or more |
| Engine | Running |
| AIR monitor during AIR: ON*1 | Completed |
| AIR monitor during AIR: OFF*2 | Completed |
| Air injection driver (open/short or out of range) | Not detected |
| AIR pressure sensor (open/short or out of range) | Not detected |
| Time after AIR in operation | 5 seconds or more |
| AIR pump | ON |
| AIR valve | Open |
| Engine speed | 400 to 3550 rpm |
| Intake air amount | Less than 99 gm/sec |
| Time after engine start | 1 second or more |
| Time after AIR in operation | 10 seconds or more |
| AIR pump | OFF |
| AIR valve | Closed |
| Engine speed | Less than 2800 rpm |
| AIR monitor during AIR: ON | Completed |
| Time after engine started | 1 second or more |
| Battery voltage | 11 V or higher |
| Atmospheric pressure | 45 kPa (337.5 mmHg) or more |
| Engine | Running |
| AIR monitor during AIR: ON*3 | Completed |
| Air injection driver (open/short or out of range) | Not detected |
| AIR pressure sensor (open/short or out of range) | Not detected |
| *3: Air flow pattern check condition during AIR monitor during AIR: ON | - |
| Time after AIR in operation | 1 second or more |
| AIR valve | Open |
| Either condition is met | (a) or (b) |
| (a) Secondary Air Injection OFF (Condition 1) | Met |
| (b) Secondary Air Injection OFF (Condition 3) | Met |
| Either condition is met | (a) or (b) |
| (a) Secondary Air Injection ON (Condition 2) | Met |
| (b) Secondary Air Injection ON (Condition 4) | Met |
| Cumulative pressure pulsation | (a) or (b) |
| (a) Air flow value at Bank 1 or Bank 2 | 140 L/min or less |
| (b) Air flow value at Bank 1 and Bank 2 | 140 L/min or less |
| Following conditions are met during AIR ON | - |
| Cumulative pressure pulsation | 10 kPa or higher |
| AIR pressure | 2.4 kPa or higher |
| Following conditions are met during AIR ON | - |
| Cumulative pressure pulsation | 10 kPa or higher |
| AIR pressure | Below 2.4 kPa |
| Following conditions are met during AIR ON | - |
| Cumulative pressure pulsation | Below 10 kPa |
| AIR pressure | 2.4 kPa or higher |
| Following conditions are met during AIR ON | - |
| Cumulative pressure pulsation | Below 10 kPa |
| AIR pressure | Below 2.4 kPa |
| Following conditions are met during AIR OFF | - |
| Cumulative pressure pulsation | 30 kPa or higher |
| AIR pressure | 2.4 kPa or higher |
| Following conditions are met during AIR OFF | - |
| Cumulative pressure pulsation | 30 kPa or higher |
| AIR pressure | Below 2.4 kPa |
| Following conditions are met during AIR OFF | - |
| Cumulative pressure pulsation | Below 30 kPa |
| AIR pressure | 2.4 kPa or higher |
| Following conditions are met during AIR OFF | - |
| Cumulative pressure pulsation | Below 30 kPa |
| AIR pressure | Below 2.4 kPa |
Refer to Checking Monitor Status (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>CHECKING MONITOR STATUS).
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds.
Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
If ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear DTCs (if output) (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the Techstream initialization is finished.
Perform the System Check operation by pressing ENTER (Next).
Perform the following to confirm the AIR system pending codes: Press the ENTER (Exit).
Check for pending DTCs.
No pending DTC is output.
After the "Secondary Air Injection Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P2444, P2445, P2446 or P2447.
Check the DTC judgment result.
| Tester Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| N/A | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
If no permanent DTC is output, the system is normal.
If a permanent DTC is output, the system is malfunctioning.
Turn the ignition switch off.
Refer to DTC P0412 (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>P0412).
Determination by ECM monitoring:
The ECM locates malfunctions in the Secondary Air Injection (AIR) system by detecting the pressure in the AIR passage between the air pump and Air Switching Valve (ASV) and stores a DTC. Soon after cold engine starts, the monitor runs for a short time while the AIR system is both ON and OFF. The ECM detects both the pressure and the exhaust pulsation and compares them.
The following 8 patterns are AIR system pressure conditions in the AIR system passage.
| Air Pump | ON |
| Air Switching Valve | Open |
| Pressure | 2.4 kPa or more |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Less than 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | ON |
| Air Switching Valve | Closed |
| Pressure | 2.4 kPa or more |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | OFF |
| Air Switching Valve | Close |
| Pressure | Less than 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | ON |
| Air Switching Valve | Open |
| Pressure | 2.4 kPa or more |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Less than 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | ON |
| Air Switching Valve | Closed |
| Pressure | 2.4 kPa or more |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | OFF |
| Air Switching Valve | Close |
| Pressure | Less than 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation not detected |
If the detected pressure is high, the air pump is assumed to be ON and if it alternates sharply, the ASV is assumed to be open. The ECM locates malfunctions from the combination of pressures detected when the AIR system is ON and OFF.
The exhaust pulsation value is calculated in the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
In case 3 and 7, as the pressure sensor detects a slight pump operation pulsation, the detected value is not constant. Since the pump outlet is blocked by closing the ASV, the average pressure is higher than in case 1 (approximately 10 to 30 kPa).
In case 1, the average pressure is approximately 3 to 11 kPa. The value of 2.4 kPa indicated in the table above is a threshold for detecting pump malfunctions.
| Detected Conditions while AIR operating:
Air pump ON, ASV Open |
Detected Conditions while AIR not operating:
Air pump OFF, ASV Closed |
ECM Determination | DTCs Output |
|---|---|---|---|
| Case 1 | Case 8 | Normal | - |
| Case 1 | Case 6 | ASV stuck open | P2440
or P2442 |
| Case 1 | Case 7 | Air pump stuck ON | P2444
or P2446 |
| Case 2 | Case 8 | Air pump stuck OFF | P2445
or P2447 |
| Case 3 | Case 8 | ASV stuck closed | P2441
or P2443 |
| Case 1 | Case 5 | ASV stuck open and air pump stuck ON | P2440 and P2444
or P2442 and P2446 |
| Case 2 | Case 6 | ASV stuck open and air pump stuck OFF | P2440 and P2445
or P2442 and P2447 |
| Case 3 | Case 7 | ASV stuck closed and air pump stuck ON | P2441 and P2444
or P2443 and P2446 |
| Case 4 | Case 8 | ASV stuck closed and air pump stuck OFF | P2441 and P2445
or P2443 and P2447 |
If the vacuum hose between the ASV and the pressure sensor is not connected correctly, case 4 may occur.
By using the Techstream to perform the Secondary Air Injection Check operation in the System Check, the air-fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions. Furthermore, Pending Codes also can be checked by performing Utility / Secondary Air Injection Check / Automatic Mode after the repair.
Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
System Check:
The pressure in the secondary air passage can be checked using the Techstream.
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: OFF, ASV1 CLOSE, AIR PUMP 2: OFF, ASV2 CLOSE.
When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Check that the air pump (AIR PUMP), ASV and pressure in the AIR system passage (PRESSURE) displayed on the Techstream indicate the conditions shown in the table below.
| Operation | AIR PUMP | ASV | PRESSURE*1 | PULSATION*2 |
|---|---|---|---|---|
| AIR PUMP: ON, ASV: OPEN | ON | OPEN | 2.4 kPa or more | 10 kPa or more |
| AIR PUMP: OFF, ASV: CLOSE | OFF | CLOSE | Less than 2.4 kPa | Less than 30 kPa |
*1:
Average pumping pressure (gauge pressure). The pressure should be 2.4 kPa or more when the AIR system operates.
*2:
The cumulative exhaust pulsation calculated by the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
Turn the ignition switch off.
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds.
Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
If an ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
| Result | Proceed to |
|---|---|
| P2444, P2445, P2446 and/or P2447 are output | A |
| P2444, P2445, P2446 and/or P2447 and P0418 and/or P0419 are output | B |
| P2444, P2445, P2446 and/or P2447 and other DTCs (except P0418 and P0419) are output | C |
If any DTCs other than P0418, P0419, P2444, P2445, P2446 and/or P2447 are output, troubleshoot those DTCs first.
A
B
C
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Read the values of Air Pump Freeze, Air Pump2 Freeze, Air Switching Valve Freeze and Air Switching Valve2 Freeze from the freeze frame data recorded previously.
Referring to the following table, proceed to the appropriate step according to the result of the data reading.
| Result | Proceed to | |||
|---|---|---|---|---|
| Air Pump Freeze | Air Pump2 Freeze | Air Switching Valve Freeze | Air Switching Valve2 Freeze | |
| OFF | OFF | OFF | OFF | B |
| Except above | A | |||
A
B
Disconnect the air pump connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT/ Active Test / Activate the Air Pump Heater.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D35-1 (APH+) - Body ground | Activate the Air Pump Heater is ON | 11 to 14 V |
| D36-1 (APH+) - Body ground | Activate the Air Pump Heater is ON | 11 to 14 V |
OK
NG
Inspect the air pump (See page Engine / Hybrid System>3UR-FBE EMISSION CONTROL>AIR PUMP>INSPECTION).
OK
NG
Inspect the air pump heater relay (AI-HTR) (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the air pump heater relay (AI-HTR).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| AI-HTR relay terminal 3 - Body ground | Always | 11 to 14 V |
OK
NG
Remove the air pump heater relay (AI-HTR).
Disconnect the air pump connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| AI-HTR relay terminal 5 - D35-1 (APH+) | Always | Below 1 Ω |
| AI-HTR relay terminal 5 - D36-1 (APH+) | Always | Below 1 Ω |
| D35-3 (APHG) - Body ground | Always | Below 1 Ω |
| D36-3 (APHG) - Body ground | Always | Below 1 Ω |
| AI-HTR relay terminal 5 or D35-1 (APH+) - Body ground | Always | 10 kΩ or higher |
| AI-HTR relay terminal 5 or D36-1 (APH+) - Body ground | Always | 10 kΩ or higher |
OK
NG
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: OFF, ASV1: CLOSE, AIR PUMP 2: OFF, ASV2: CLOSE.
When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Check that the air pump (AIR PUMP), ASV and pressure in the AIR system passage (PRESSURE) status displayed on the Techstream indicate the conditions shown in the table below.
| Operation | AIR PUMP | ASV | PRESSURE* |
|---|---|---|---|
| AIR PUMP: ON, ASV: OPEN | ON | OPEN | 2.4 kPa or more |
| AIR PUMP: OFF, ASV: CLOSE | OFF | CLOSE | Less than 2.4 kPa |
*: Average pumping pressure. The pressure should be 2.4 kPa or more when the AIR system operates.
Turn the ignition switch off.
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds.
Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
If an ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
OK
NG
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Clear DTCs (if output) (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the Techstream initialization is finished.
Perform the System Check operation by pressing Next.
After operating the AIR system, perform the following to confirm the AIR system pending codes: Press the Exit button.
Check pending DTCs.
Turn the ignition switch off.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
| Result | Proceed to |
|---|---|
| P2444, P2445, P2446 and/or P2447 are output | A |
| No pending DTC is output | B |
A
B
Check the vacuum hose connections with the pressure sensor and ASV.
Inspect the vacuum hose for blockages and damage.
Vacuum hose has no blockages or damage.
OK
NG
OK
NG
Check that all the pipes and hoses between the air pump and ASV are securely connected.
Inspect the pipes and hoses for blockages and damage.
AIR system piping has no blockages or damage.
OK
NG
Disconnect the D31 and D32 or D33 and D34 AID connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D32-1 (E) - Body ground | Always | Below 1 Ω |
| D34-1 (E2) - Body ground | Always | Below 1 Ω |
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| D31-1 (BATT) - Body ground | Always | 11 to 14 V (near battery voltage) |
| D32-5 (+B) - Body ground | Ignition switch ON | 11 to 14 V (near battery voltage) |
| D33-1 (BAT2) - Body ground | Always | 11 to 14 V (near battery voltage) |
| D34-5 (+B2) - Body ground | Ignition switch ON | 11 to 14 V (near battery voltage) |
OK
NG
Disconnect the D56 ECM connector.
Disconnect the D32 or D34 AID connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D56-54 (AIRP) - D32-4 (SIP) | Always | Below 1 Ω |
| D56-53 (ARP2) - D34-4 (SIP2) | Always | Below 1 Ω |
| D56-54 (AIRP) or D32-4 (SIP) - body ground | Always | 10 kΩ or higher |
| D56-53 (ARP2) or D34-4 (SIP2) - body ground | Always | 10 kΩ or higher |
OK
NG
Start the engine and warm it up.
Turn the ignition switch off.
Connect the 400 A probe of an ammeter to the positive (+) wire of the air pump.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream ON.
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: OFF, ASV1: CLOSE, AIR PUMP 2: OFF, ASV2: CLOSE.
When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Measure the current while the air pump is on and off.
| Tester Operation | Air Pump | ASV | Specified Condition |
|---|---|---|---|
| AIR PUMP: ON, ASV: OPEN | ON | OPEN | 10 to 40 A |
| AIR PUMP: OFF, ASV: CLOSE | OFF | CLOSE | Below 1 A |
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds.
Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the Techstream is prohibited, the Techstream display indicates the prohibition (WAIT or ERROR).
If ERROR is displayed on the Techstream during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
OK
NG
Replace the air pump (See page Engine / Hybrid System>3UR-FBE EMISSION CONTROL>AIR PUMP>REMOVAL).
NEXT
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Clear DTCs (if output) (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the Techstream initialization is finished.
Perform the System Check operation by pressing Next.
After operating the AIR system, perform the following to confirm the AIR system pending codes: Press the Exit button.
Check pending DTCs.
Turn the ignition switch off.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
| Result | Proceed to |
|---|---|
| No pending DTC is output | A |
| P2444, P2445, P2446 and/or P2447 are output | B |
A
B
Disconnect the D32 or D34 AID connector.
Connect terminals DI and SIV or DI2 and SIV2 of the wire harness connector for the AID.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV 1: OPEN, AIR PUMP 2: ON, ASV 2: OPEN.
When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system forced operation while the engine is idling.
Measure the voltage between the SIV and E or SIV2 and E2 terminals of the ECM connector when the AIR system is ON and OFF.
Turn the ignition switch off.
Performing Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If it is necessary to repeat the check, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D32-3 (SIV) - D32-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| D34-3 (SIV2) - D34-1 (E2) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| D32-3 (SIV) - D32-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
| D34-3 (SIV2) - D34-1 (E2) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
Connect terminals DI and SIP or DI2 and SIP2 of the wire harness connector for the AID.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV 1: OPEN, AIR PUMP 2: ON, ASV 2: OPEN.
When Manual Mode is selected, the Techstream initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system forced operation while the engine is idling.
Measure the voltage between the SIP and E or SIP2 and E2 terminals of the ECM connector when the AIR system is ON and OFF.
Turn the ignition switch off.
Performing Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If it is necessary to repeat the check, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D32-4 (SIP) - D32-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| D34-4 (SIP2) - D34-1 (E2) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| D32-4 (SIP) - D32-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
| D34-4 (SIP2) - D34-1 (E2) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
OK
NG
Replace the air injection control driver (See page Engine / Hybrid System>3UR-FBE EMISSION CONTROL>AIR INJECTION DRIVER>REMOVAL).
NEXT
Start the engine and warm it up.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Clear DTCs (if output) (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the Techstream initialization is finished.
Perform the System Check operation by pressing Next.
After operating the AIR system, perform the following to confirm the AIR system pending codes: Press the Exit button.
Check pending DTCs.
Turn the ignition switch off.
No pending DTC is output.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the ignition switch turned to ON or the engine running.
Turn the ignition switch off when the Secondary Air Injection Check operation finishes.
OK
NG