CAN COMMUNICATION SYSTEM > Short to GND in CAN Bus Line |
| Symptoms | Trouble Area |
| The resistance between terminals 6 (CANH) and 4 (CG), or terminals 14 (CANL) and 4 (CG) of the DLC3 is below 200 Ω. |
|


| 1.CHECK FOR SHORT TO GND IN CAN BUS WIRE (ECM MAIN BUS WIRE) |
Turn the ignition switch off.
![]() |
Disconnect the ECM connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D1-6 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| D1-14 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 2.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NETWORK GATEWAY ECU MAIN BUS WIRE) |
![]() |
Disconnect the network gateway ECU connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D1-6 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| D1-14 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 3.CHECK FOR SHORT TO GND IN CAN BUS WIRE (DLC3 BRANCH WIRE) |
Disconnect the junction connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D1-6 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| D1-14 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 4.CHECK FOR SHORT TO GND IN CAN BUS WIRE (JUNCTION CONNECTOR - NETWORK GATEWAY ECU MAIN BUS WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-6 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-17 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| Result | Proceed to |
| OK (without VSC) | A |
| OK (with VSC) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 5.CHECK FOR SHORT TO GND IN CAN BUS WIRE (JUNCTION CONNECTOR - ECM MAIN BUS WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-7 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-18 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 6.CHECK FOR SHORT TO GND IN CAN BUS WIRE (JUNCTION CONNECTOR - CAN JUNCTION CONNECTOR MAIN BUS WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-7 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-18 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 7.CHECK FOR SHORT TO GND IN CAN BUS WIRE (SKID CONTROL ECU BRANCH WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-10 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-21 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 8.CHECK FOR SHORT TO GND IN CAN BUS WIRE (STEERING ANGLE SENSOR BRANCH WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-11 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-22 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| Result | Proceed to |
| OK (without Dynamic radar cruise control) | A |
| OK (with Dynamic radar cruise control) | B |
| NG | C |
|
| ||||
|
| ||||
| A | |
| 9.CHECK FOR SHORT TO GND IN CAN BUS WIRE (DISTANCE CONTROL ECU BRANCH WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-5 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-16 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 10.CHECK FOR SHORT TO GND IN CAN BUS WIRE (CAN JUNCTION CONNECTOR - JUNCTION CONNECTOR MAIN BUS WIRE) |
Disconnect the CAN junction connector (J49).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J49-3 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J49-7 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 11.CHECK FOR SHORT TO GND IN CAN BUS WIRE (CAN JUNCTION CONNECTOR - ECM MAIN BUS WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J49-4 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J49-6 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 12.CHECK FOR SHORT TO GND IN CAN BUS WIRE (YAW RATE SENSOR BRANCH WIRE) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J49-1 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J49-2 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 13.CHECK FOR SHORT TO GND IN CAN BUS WIRE (SKID CONTROL ECU BRANCH WIRE) |
![]() |
Disconnect the skid control ECU connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-10 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-21 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 14.CHECK FOR SHORT TO GND IN CAN BUS WIRE (STEERING ANGLE SENSOR BRANCH WIRE) |
![]() |
Disconnect the steering angle sensor connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-11 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-22 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 15.CHECK FOR SHORT TO GND IN CAN BUS WIRE (DISTANCE CONTROL ECU BRANCH WIRE) |
![]() |
Disconnect the distance control ECU connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J17-5 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J17-16 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 16.CHECK FOR SHORT TO GND IN CAN BUS WIRE (YAW RATE SENSOR BRANCH WIRE) |
![]() |
Disconnect the yaw rate sensor connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J49-1 (CANH) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
| J49-2 (CANL) - D1-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||