Working on 12 V vehicle electrical system.
Risk of short circuits! Risk of fire!
Detach battery earth lead from battery.
Pyrotechnic components.
Danger! Life-threatening injuries!
All work on pyrotechnic parts may be carried out by technically experienced and appropriately trained personnel only.
Some of these service operations affect the SRS airbag system. Read the precautionary notices concerning the SRS airbag system before servicing.
Replace any damaged part or ones that have been dropped.
For additional information see:
Click hereVehicle Interior>SUPPLEMENTAL RESTRAINT SYSTEMS>AIRBAG SYSTEM>PRECAUTION
Electrostatic discharge.
Damage to or destruction of electrical components.
Leave electrical components in original packaging until just before they are installed. Use the original packaging only for any return shipments. Always package removed components straight away.
Only touch the housings of electrical components. Do not touch pins or multi-pin connectors directly.
Antistatic work clothing and antistatic shoes (with ESD symbol).
For additional information see:
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Before performing work on electronic components, disconnect the cable from the negative (-) battery terminal to prevent damage to the electrical system or components.
When disconnecting the cable, turn the START-STOP button (engine switch) and headlight switch off and loosen the cable nut completely. Perform these operations without twisting or prying on the cable. Then disconnect the cable.
Clock settings, radio settings, audio system memory, DTCs and other data will be cleared when the cable is disconnected from the negative (-) battery terminal. Write down any necessary data before disconnecting the cable.
Use the same procedure for RHD and LHD vehicles.
The following procedure is for LHD vehicles.
1.REMOVE INSTRUMENT PANEL SAFETY PAD ASSEMBLY
2.REMOVE USB HUB
Electrostatic discharge.
Damage to or destruction of electrical components.
Leave electrical components in original packaging until just before they are installed. Use the original packaging only for any return shipments. Always package removed components straight away.
Only touch the housings of electrical components. Do not touch pins or multi-pin connectors directly.
Antistatic work clothing and antistatic shoes (with ESD symbol).
For additional information see:
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Unlock plug connections (1) and disconnect.
Loosen the T30 screws (1).
Remove the USB hub (2).
Unlock plug connections (1) and disconnect to remove the No. 5 instrument panel wire (2).