Home › TRANSMISSION · A340F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0976    Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

DTC    P0977    Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operation of shift solenoid valves S1 and S2, which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short-circuited solenoid (Click here).

DTC No.
DTC Detection Condition
Trouble Area
P0976
ECM detects a short in the solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1 trip detection logic).
  1. Wire harness or connector
  2. Transmission wire
  3. Shift solenoid valve S2
  4. ECM
P0977
ECM detects an open in the solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1 trip detection logic).
  1. Wire harness or connector
  2. Transmission wire
  3. Shift solenoid valve S2
  4. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in either shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S2 is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S2 circuit.
When shift solenoid valve S2 is OFF, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve S2 circuit (Click here).

MONITOR STRATEGY


Related DTCs
P0976: Shift solenoid valve S2/Range check (Low resistance)
P0977: Shift solenoid valve S2/Range check (High resistance)
Required sensors/Components
Shift solenoid valve S2
Frequency of operation
Continuous
Duration
0.128 seconds or more
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs not present.
None
Battery voltage
8 V or higher
Ignition switch
ON
Starter
OFF

P0976: Range Check (Low Resistance) 
Shift solenoid valve S2
ON

P0977: Range Check (High Resistance) 
Shift solenoid valve S2
OFF

TYPICAL MALFUNCTION THRESHOLDS


P0976: Range Check (Low Resistance) 
Shift solenoid valve S2 resistance
8 Ω or less

P0977: Range Check (High Resistance) 
Shift solenoid valve S2 resistance
100 kΩ or higher

COMPONENT OPERATING RANGE


Shift solenoid valve S2 resistance
11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM


C186141E13


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


HINT:
Shift solenoid valve S2 is turned ON/OFF normally when the shift lever is in D.

ECM gear shift command
1st
2nd
3rd
4th
Shift solenoid valve S2
OFF
ON
ON
OFF

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2)


    C214964E03
  1. Disconnect the transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    8 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C223988E04
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E5-8 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω

    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE S2


    C214963E01
  1. Remove shift solenoid valve S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) → Shift solenoid valve S2 connector
    2. Battery negative (-) → Shift solenoid valve S2 body
    Valve moves and makes an operating noise

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve S2)


NG
REPLACE SHIFT SOLENOID VALVE S2 (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)