Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

Refer to DTC P2714 .

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic)
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the linear solenoid valve (SLT) circuit, the ECM interprets this as a fault.
The ECM turns on the MIL and stores the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever this DTC is not present.
None
Ignition switch
ON
Starter
OFF

Condition (A) 
Solenoid current cut status
Not cut
Battery voltage
11 V or more

Condition (B) 
Battery voltage
8 V or more

TYPICAL MALFUNCTION THRESHOLDS


Condition (A) 
Output signal monitor
No signal

Condition (B) 
Hybrid IC status
Fail

COMPONENT OPERATING RANGE


Output signal duty
Less than 100%

WIRING DIAGRAM


C186142E06


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

1.INSPECT TRANSMISSION WIRE (SLT)


    G020667E91
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    14 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C189656E02
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E10-34 (SLT+) - E10-35 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    E10-34 (SLT+) - Body ground
    Always
    10 kΩ or higher
    E10-35 (SLT-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLT


    C151311E63
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)