DTC P2740 Transmission Fluid Temperature Sensor "B" Circuit |
DTC P2742 Transmission Fluid Temperature Sensor "B" Circuit Low Input |
DTC P2743 Transmission Fluid Temperature Sensor "B" Circuit High Input |
| No. 2 ATF Temperature Sensor Status | Detection Condition | Symptom | Recovery Condition |
| Sensor is normal |
|
|
|
|
|
| |
When conditions (a) and (b) are satisfied continually
|
|
| |
| Sensor is short |
|
|
|
|
|
|
| DTC No. | DTC Detection Condition | Trouble Area |
| P2742 | No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V) for 0.5 seconds or more (1-trip detection logic) |
|
| P2743 | No. 2 ATF temperature sensor resistance is more than 156 kΩ (4.915 V) for 0.5 seconds or more, or either of the following conditions is met (1-trip detection logic) |
|
| Condition (A): 15 minutes or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less. | ||
| Condition (B): 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (-20.875°F). |
| DTC No. | DTC Detection Condition | Trouble Area |
| P2740 | Conditions (a) and (b) are detected momentarily within 0.5 seconds when neither P2742 nor P2743 is detected (1-trip detection logic)
|
|
| P2742 | No. 2 ATF temperature sensor resistance (voltage) is less than 25 Ω (0.046 V) for 0.5 seconds or more (1-trip detection logic) |
|
| P2743 | No. 2 ATF temperature sensor resistance is more than 156 kΩ (4.915 V) for 0.5 seconds or more when 15 minutes or more have passed after the engine is started. (1-trip detection logic) |
|

| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 2 | No. 2 ATF temperature sensor value/ Min.: -40°C (-40°F) Max.: 215°C (419°F) |
| If value is -40°C (-40°F) or 215°C (419°F), No. 2 ATF temperature sensor circuit is open or short circuited |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector from the transmission.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (OT2-) - 9 (OT2+) | Always | 79 Ω to 156 kΩ |
| 1 (OT2-) - Body ground | Always | 10 kΩ or higher |
| 9 (OT2+) - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Connect the transmission wire connector to the transmission.
Disconnect the connectors from the ECM.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E11-11 (THO2) - E10-8 (ETHW) | Always | 79 Ω to 156 kΩ |
| E11-11 (THO2) - Body ground | Always | 10 kΩ or higher |
| E10-8 (ETHW) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||