Home › SECURITIES › ENGINE IMMOBILISER › ENGINE IMMOBILISER SYSTEM

DTC    B279A    Theft Deterrent System Communication Line High Fixation

for Preparation Click here


DESCRIPTION

If the communication line (EFIO-IMI) to the transponder key ECU is stuck on HI output, the ECM outputs this DTC.

DTC Code
DTC Detection Condition
Trouble Area
B279A
When communication line (EFIO-IMI) between ECM and transponder key ECU is stuck on HI output for 6 seconds or more
  1. Wire harness or connector
  2. Transponder key ECU assembly
  3. ECM

WIRING DIAGRAM


B260849E01


INSPECTION PROCEDURE

HINT:
  1. If the transponder key ECU assembly is replaced, register the key and ECU communication ID.
  2. If the ECM is replaced, register the ECU communication ID.

1.CLEAR DTC
  1. Clear the DTC (Click here).


NEXT


2.CHECK FOR DTC
  1. Check for DTC (Click here).
    Result 
    Result
    Proceed to
    DTC B279A is output
    A
    DTC B279A and other DTCs are output
    B

    HINT:
    If any DTCs other than B279A are output, troubleshoot those DTCs first.



B
GO TO DIAGNOSTIC TROUBLE CODE CHART (Click here)
A


3.CHECK HARNESS AND CONNECTOR (TRANSPONDER KEY ECU - ECM)


    B205063E03
  1. Disconnect the T10 ECU connector.

  1. Disconnect the E7 or E14 ECM connector.

  1. Measure the resistance and voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    T10-13 (EFIO) - E14-14 (IMI)*1
    Always
    Below 1 Ω
    T10-13 (EFIO) or E14-14 (IMI)*1 - Body ground
    Always
    10 kΩ or higher
    T10-13 (EFIO) - E7-16 (IMI)*2
    Always
    Below 1 Ω
    T10-13 (EFIO) or E7-16 (IMI)*2 - Body ground
    Always
    10 kΩ or higher

    1. *1: for 1GR-FE
    2. *2: for 2TR-FE

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    T10-13 (EFIO) - Body ground
    Always
    Below 1 V

  1. Reconnect the ECU and ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT TRANSPONDER KEY ECU (OUTPUT)


    B169769E06
  1. Measure the waveform.
    Waveform 1 
    Tester Connection
    Tool Setting
    Switch Condition
    T10-13 (EFIO) - T10-16 (GND)
    10 V/DIV., 500 msec./DIV.
    Ignition switch ON

    OK:
    Waveform is output normally (see illustration).

    Result 
    Result
    Proceed to
    OK
    A
    NG (1GR-FE)
    B
    NG (2TR-FE)
    C



B
REPLACE ECM (Click here)

C
REPLACE ECM (Click here)
A


5.CHECK TRANSPONDER KEY ECU (POWER SOURCE AND BODY GROUND)
B128338E52
  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    T10-1 (+B) - T10-16 (GND)
    Ignition switch ON
    11 to 14 V
    T10-16 (GND) - Body ground
    Always
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE TRANSPONDER KEY ECU (Click here)