CONDENSER > INSTALLATION |
| 1. INSTALL COOLER DRYER |
![]() |
Using pliers, install the cooler dryer.
![]() |
Apply a sufficient amount of compressor oil to the contact surfaces of a new O-ring and the cap.
Install the O-ring to the cap.
![]() |
Using a 14 mm socket hexagon wrench, install the cap to the modulator.
| 2. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser with the 2 bolts, as shown in the illustration.
| 3. CONNECT AIR CONDITIONING TUBE AND ACCESSORY ASSEMBLY |
![]() |
Remove the attached vinyl tape from the pipe and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the pipe joint.
Install the O-ring on the air conditioning tube and accessory.
Connect the air conditioning tube and accessory on the cooler condenser with the 2 bolts.
| 4. CONNECT DISCHARGE HOSE |
![]() |
Remove the attached vinyl tape from the hose and the connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the hose joint.
Install the O-ring on the discharge hose.
Connect the discharge hose on the cooler condenser with the bolt.
| 5. INSTALL RADIATOR ASSEMBLY |
for 1GR-FE:
Install the radiator (Click here).
for 2UZ-FE:
Install the radiator (Click here).
for 3UR-FE:
Install the radiator (Click here).
for 3UR-FBE:
Install the radiator (Click here).
| 6. INSTALL FRONT BUMPER COVER |
for Steel Type Bumper:
Install the front bumper cover (Click here).
for Resin Type Bumper:
Install the front bumper cover (Click here).
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 8. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 9. WARM UP ENGINE |
Warm up the engine at less than 1500 rpm for 1 minute or more after charging the refrigerant.
| 10. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under the following conditions:
![]() |
Using a halogen leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.
| 11. CHECK SRS WARNING LIGHT |
Check the SRS warning light (Click here).