DTC B1805/52 Short in Front Passenger Side Squib Circuit |
DTC B1806/52 Open in Front Passenger Side Squib Circuit |
DTC B1807/52 Short to GND in Front Passenger Side Squib Circuit |
DTC B1808/52 Short to B+ in Front Passenger Side Squib Circuit |
| DTC Code | Detection Condition | Trouble Area |
| B1805/52 | When one of the following conditions is met:
|
|
| B1806/52 | When one of the following conditions is met:
|
|
| B1807/52 | When one of the following conditions is met:
|
|
| B1808/52 | When one of the following conditions is met:
|
|

| 1.CHECK FRONT PASSENGER AIRBAG (FRONT PASSENGER SIDE SQUIB) |
![]() |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the front passenger airbag.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector E (orange connector).
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector E.
Check that the instrument panel wire connectors (on the front passenger airbag side) are not damaged.
|
| ||||
| OK | |
| 3.CHECK FRONT PASSENGER SIDE SQUIB CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| I2-1 (P+) - Body ground | Ignition switch ON | Below 1 V |
| I2-2 (P-) - Body ground |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I2-1 (P+) - I2-2 (P-) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| I2-1 (P+) - I2-2 (P-) | Always | 1 MΩ or higher |
| I2-1 (P+) - Body ground | ||
| I2-2 (P-) - Body ground |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR |
![]() |
Connect the connectors to the front passenger airbag and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
| Result | Proceed to |
| DTC B1805, B1806, B1807 or B1808 is output (for Column Shift Type) | A |
| DTC B1805, B1806, B1807 or B1808 is output (for Floor Shift Type) | B |
| DTC B1805, B1806, B1807 or B1808 is not output | C |
|
| ||||
|
| ||||
| C | ||
| ||
| 5.CHECK INSTRUMENT PANEL WIRE (CENTER AIRBAG SENSOR - INSTRUMENT PANEL WIRE ASSEMBLY) |
![]() |
Restore the released activation prevention mechanism of connector B to the original condition.
Disconnect the instrument panel wire connector from the instrument panel wire assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| JI1-1 - Body ground | Ignition switch ON | Below 1 V |
| JI1-2 - Body ground |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| JI1-1 - JI1-2 | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| JI1-1 - JI1-2 | Always | 1 MΩ or higher |
| JI1-1 - Body ground | ||
| JI1-2 - Body ground |
|
| ||||
| OK | ||
| ||