LIN COMMUNICATION SYSTEM > Integration Control and Panel Assembly Communication Error |

| 1.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - INTEGRATION CONTROL AND PANEL) |
![]() |
Disconnect the J37 integration control and panel assembly connector.
Disconnect the J19 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J19-37 (LIN1) - J37-3 (STX) | Always | Below 1 Ω |
| J19-37 (LIN1) or J37-3 (STX) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (INTEGRATION CONTROL AND PANEL - BATTERY AND BODY GROUND) |
![]() |
Disconnect the J37 integration control and panel assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| J37-1 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| J37-16 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch OFF | Below 1 V |
|
| ||||
| OK | |
| 3.CHECK INTEGRATION CONTROL AND PANEL ASSEMBLY (OPERATION) |
Temporarily replace the integration control and panel assembly with a new or normally functioning one.
For Column Shift Type, refer to the following procedures (Click here).
For Floor Shift Type, refer to the following procedures (Click here).
Check that the malfunction disappears.
|
| ||||
| OK | ||
| ||