DTC B1905/74 Short in Front Passenger Side Pretensioner Squib Circuit |
DTC B1906/74 Open in Front Passenger Side Pretensioner Squib Circuit |
DTC B1907/74 Short to GND in Front Passenger Side Pretensioner Squib Circuit |
DTC B1908/74 Short to B+ in Front Passenger Side Pretensioner Squib Circuit |
| DTC Code | Detection Condition | Trouble Area |
| B1905/74 | When one of the following conditions is met:
|
|
| B1906/74 | When one of the following conditions is met:
|
|
| B1907/74 | When one of the following conditions is met:
|
|
| B1908/74 | When one of the following conditions is met:
|
|

| 1.CHECK FRONT SEAT OUTER BELT RH (FRONT PRETENSIONER SQUIB RH) |
![]() |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the front seat outer belt RH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
| Result | Proceed to |
| DTC B1905, B1906, B1907 or B1908 is not output (for Regular Cab) | A |
| DTC B1905, B1906, B1907 or B1908 is not output (for Double Cab) | B |
| DTC B1905, B1906, B1907 or B1908 is not output (for CrewMax) | C |
| DTC B1905, B1906, B1907 or B1908 is output | D |
|
| ||||
|
| ||||
|
| ||||
| D | |
| 2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the No. 2 floor wire connector (on the front seat outer belt RH side) is not damaged.
|
| ||||
| OK | |
| 3.CHECK NO. 2 FLOOR WIRE (FRONT PRETENSIONER SQUIB RH CIRCUIT) |
![]() |
Disconnect the connectors from the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q2-1 (R+) - Body ground | Ignition switch ON | Below 1 V |
| Q2-2 (R-) - Body ground |
Turn the ignition switch off.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q2-1 (R+) - Q2-2 (R-) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q2-1 (R+) - Q2-2 (R-) | Always | 1 MΩ or higher |
| Q2-1 (R+) - Body ground | ||
| Q2-2 (R-) - Body ground |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR |
![]() |
Connect the connectors to the front seat outer belt RH and the center airbag sensor.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check the DTCs (Click here).
| Result | Proceed to |
| DTC B1905, B1906, B1907 or B1908 is output (for Column Shift Type) | A |
| DTC B1905, B1906, B1907 or B1908 is output (for Floor Shift Type) | B |
| DTC B1905, B1906, B1907 or B1908 is not output | C |
|
| ||||
|
| ||||
| C | ||
| ||