DESCRIPTION

Shifting from 1st to 6th is performed in combination with ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short-circuited solenoid (See page Drivetrain>A760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0985 ECM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1-trip detection logic).
·

Short in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM


P0986 ECM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1-trip detection logic).
·

Open in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve SR is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.

When the shift solenoid valve SR is OFF, if its resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve SR circuit (See page Drivetrain>A760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

MONITOR STRATEGY

Related DTCs P0985: Shift solenoid valve SR/Range check (Low resistance)
P0986: Shift solenoid valve SR/Range check (High resistance)
Required sensors/Components Shift solenoid valve SR
Frequency of operation Continuous
Duration 0.128 seconds or more
MIL operation Immediately
Sequence of operation None

TYPICAL ENABLING CONDITIONS

All
The monitor will run whenever the following DTCs are not present None
Battery voltage 8 V or more
Ignition switch ON
Starter OFF

P0985: Range Check (Low Resistance)
Command to shift solenoid valve SR ON

P0986: Range Check (High Resistance)
Command to shift solenoid valve SR OFF

TYPICAL MALFUNCTION THRESHOLDS

P0985: Range Check (Low Resistance)
Shift solenoid valve SR resistance 8 Ω or less

P0986: Range Check (High Resistance)
Shift solenoid valve SR resistance 100 kΩ or more

COMPONENT OPERATING RANGE

Shift solenoid valve SR resistance 11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM

C161204E78
2.775,1.067 3.005,1.237 0.230,0.170 10 8 5.527,1.067 5.757,1.237 0.230,0.170 10 4 2.459,0.813 2.798,1.008 0.338,0.195 10 SR 5.771,0.958 6.059,1.153 0.288,0.195 10 SR 0.959,2.741 1.381,2.937 0.422,0.195 10 D83 0.959,2.916 2.709,3.111 1.751,0.195 10 Transmission Wire 1.015,1.691 2.646,1.926 1.632,0.235 10 Shift Solenoid Valve SR 5.934,3.072 6.303,3.242 0.369,0.170 10 D74 5.934,3.225 6.356,3.420 0.422,0.195 10 ECM

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>A760E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


HINT:

The shift solenoid valve SR is turned ON/OFF normally when the shift lever is in D:

ECM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SR ON ON ON ON OFF OFF


PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)
a.
C210154E20
0.057,0.005 0.373,0.206 0.317,0.202 10 *a 1.047,1.819 1.401,2.021 0.354,0.202 10 SR 1.222,1.794 1.532,1.155 false

Disconnect the D83 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
8 (SR) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SR
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
U152400E02
0.573,1.677 0.906,0.854 true 0.052,0.073 0.365,0.271 0.313,0.198 10 false *a 1.604,0.281 1.979,0.51 0.375,0.229 10 false D74 0.365,1.74 1.021,1.938 0.656,0.198 10 false 4 (SR)

Disconnect the D74 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D74-4 (SR) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SR
a.
C209929E04
0.057,0.005 0.374,0.206 0.317,0.202 10 *a 2.4,0.09 2.623,0.292 0.223,0.202 10 (+) 3.16,0.09 3.365,0.292 0.206,0.202 10 (-)

Remove shift solenoid valve SR.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SR)


OK

NG