When the blind spot monitor main switch assembly (warning canceling switch assembly) is turned on, a signal is sent to the blind spot monitor sensor RH. The blind spot monitor system operates according to this signal.
Inspect the fuse for circuits related to this system before performing the following inspection procedure.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Main SW | Blind spot monitor main switch assembly (warning canceling switch assembly) / OFF or ON | ON: Blind spot monitor main switch assembly (warning canceling switch assembly) on
OFF: Blind spot monitor main switch assembly (warning canceling switch assembly) off |
- |
| Result | Proceed to |
|---|---|
| The display changes as shown above when the blind spot monitor main switch assembly (warning canceling switch assembly) is operated. | A |
| The display does not change as shown above when the blind spot monitor main switch assembly (warning canceling switch assembly) is operated. | B |
A
B
Remove the blind spot monitor main switch assembly (warning canceling switch assembly) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR MAIN SWITCH>REMOVAL).
Inspect the blind spot monitor main switch assembly (warning canceling switch assembly) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR MAIN SWITCH>INSPECTION).
OK
NG
(See pageAudio / Visual / Telematics>PARK ASSIST / MONITORING>BLIND SPOT MONITOR MAIN SWITCH>REMOVAL)
Disconnect the blind spot monitor main switch assembly (warning canceling switch assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J124-11 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| J124-11 (B) - Body ground | Ignition switch off | Below 1 V |
| *a | Front view of wire harness connector
(to Blind Spot Monitor Main Switch Assembly [Warning Canceling Switch Assembly]) |
OK
NG
Disconnect the S6 blind spot monitor sensor RH connector.
Disconnect the J124 blind spot monitor main switch assembly (warning canceling switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| S6-8 (BSSW) - J124-8 (D) | Always | Below 1 Ω |
| S6-8 (BSSW) - Body ground | Always | 10 kΩ or higher |
OK
NG