MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and hybrid motor control inverter assembly and detects a short circuit malfunction or high-voltage system operation malfunction.
The cause of this malfunction may be one of the following:
Battery current sensor (IB) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
HV battery malfunction
No. 1 traction battery device box assembly malfunction
Hybrid motor control inverter assembly malfunction
Air conditioner system malfunction
Rear hybrid motor control inverter assembly (for AWD)
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
Hybrid vehicle control ECU malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
INSPECTION DESCRIPTION
| System Diagram Location | Inspection Content | Reason |
|---|---|---|
| *a | Check high-voltage wiring connection condition of the air conditioner compressor with motor assembly | Check for short circuit |
| *b | Check the high voltage cables between the No. 1 traction battery device box assembly and hybrid motor control inverter assembly or rear hybrid motor control inverter assembly. | Check for short circuit |
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | High-voltage circuit malfunctions between the HV battery and hybrid motor control inverter assembly.
Excessive overcurrent equal to a short occurs during precharge (time from when SMRP turns on until SMRG turns on). (1 trip detection logic) |
·
Air conditioning wire ·
Compressor with motor assembly ·
Hybrid motor control inverter assembly ·
No. 1 traction battery device box assembly ·
HV floor under wire ·
Rear hybrid motor control inverter assembly* |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
| P1C8249 | High Voltage Power Resource Circuit Over Loading | High-voltage circuit malfunctions between the HV battery and hybrid motor control inverter assembly.
Small battery overcurrent occurs during precharge (time from when SMRP turns on until SMRG turns on) and current continues to flow after precharge. (1 trip detection logic) |
·
Air conditioning wire ·
Compressor with motor assembly ·
Hybrid motor control inverter assembly ·
No. 1 traction battery device box assembly ·
HV floor under wire ·
Rear hybrid motor control inverter assembly* |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
*: for AWD
| DTC No. | Data List |
|---|---|
| P1C8149 | ·
Hybrid/EV Battery Voltage ·
Hybrid/EV Battery Current ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting |
| P1C8249 |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0AA649.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
If this DTC is output, do not turn the ignition switch to ON (READY) until the repair has been completed. This DTC means an excessive amperage flow through the system main resistor. The system main resistor may overheat and be damaged if the ignition switch is turned to ON (READY) repeatedly before repair.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1C8149 or P1C8249 are output and Microcomputer malfunction of Hybrid control system DTCs in the table below are output | A |
| P1C8149 or P1C8249 are output and Microcomputer malfunction of Hybrid battery system DTCs in the table below are output | B |
| P1C8149 or P1C8249 are output and Communication system malfunction of Hybrid control system DTCs in the table below are output | C |
| P1C8149 or P1C8249 are output and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output | D |
| P1C8149 or P1C8249 are output and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output | E |
| P1C8149 or P1C8249 are output and Sensor and actuator circuit malfunction of Hybrid battery system DTCs in the table below are output | F |
| P1C8149 or P1C8249 are output and System malfunction of Hybrid control system DTCs in the table below are output | G |
| P1C8149 or P1C8249 are output and System malfunction of Motor generator control system DTCs in the table below are output | H |
| P1C8149 or P1C8249 are output and DTCs other than the DTCs in the table below are output | I |
| Only P1C8149 or P1C8249 is output | J |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Communication system malfunction | Hybrid control system | U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message |
| Sensor and actuator circuit malfunction | Hybrid control system | P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
| Motor generator control system | P0A1114 | DC/DC Converter Enable Circuit Short to Ground or Open | |
| P0A1112 | DC/DC Converter Enable Circuit Short to Battery | ||
| P1CCC96 | DC/DC Converter Enable Component Internal Failure | ||
| Hybrid battery system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| System malfunction | Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
| Motor generator control system | P0D3319 | DC/DC Converter Circuit Current Above Threshold | |
P1C8149 or P1C8249 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
C
D
E
F
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
G
H
I
J
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the air conditioning wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | Air Conditioning Wire
(Hybrid Motor Control Inverter Assembly Side) |
| *b | Tip of Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection
(Tester Probe Polarity) |
Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b2)Location & Routingewd_type=routing;type=c;code=b2 Click Connector(b2)Engine Compartment>HV Air Conditioning Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=b2;pinno=2,1 |
||
| b2-2 (ACPE) (Negative (-) probe) - b2-1 (ACPB) (Positive (+) probe) | Ignition switch off | 100 kΩ or higher |
Do not use a megohmmeter.
Read the resistance after the value has stabilized.
Be sure to inspect with connecting the tester probes to the tips of the terminal.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the air conditioning wire connector.
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3)Location & Routingewd_type=routing;type=c;code=a3 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 |
||
| a3-1 (CBI) - a3-2 (CEI) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the air conditioning wire connector from the hybrid motor control inverter assembly.
Disconnect the b1 air conditioning wire from the compressor with motor assembly.
Procedure1
| *a | Air Conditioning Wire
(Hybrid Motor Control Inverter Assembly Side) |
| *b | Tip of Terminal |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(b2)Location & Routingewd_type=routing;type=c;code=b2 Click Connector(b2)Engine Compartment>HV Air Conditioning Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=b2;pinno=2,1 |
||
| b2-2 (ACPE) - b2-1 (ACPB) | Ignition switch off | 10 kΩ or higher |
Be sure to inspect with connecting the tester probes to the tips of the terminal.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the air conditioning wire connector to the hybrid motor control inverter assembly.
Reconnect the b1 air conditioning wire to the compressor with motor assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the HV floor under wire connectors from the No. 1 traction battery device box assembly.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3)Location & Routingewd_type=routing;type=c;code=a3 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 |
||
| a3-1 (CBI) - a3-2 (CEI) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector to the hybrid motor control inverter assembly.
Reconnect the HV floor under wire connectors to the No. 1 traction battery device box assembly.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3)Location & Routingewd_type=routing;type=c;code=a3 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 |
||
| a3-1 (CBI) - a3-2 (CEI) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect the HV floor under wire from the rear hybrid motor control inverter assembly.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3)Location & Routingewd_type=routing;type=c;code=a3 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 |
||
| a3-1 (CBI) - a3-2 (CEI) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Connect the HV floor under wire from the rear hybrid motor control inverter assembly.
Reconnect the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Disconnect the HV battery pack wire connectors from the No. 1 traction battery device box assembly.
Procedure1
| *a | HV battery pack wire
(No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c1,c2)Location & Routingewd_type=routing;type=c,c;code=c1,c2 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 |
||
| c1-1 (CBI) - c2-1 (CEI) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV battery pack wire connectors from the No. 1 traction battery device box assembly.
Reconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Reconnect the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect the HV floor under wire from the rear hybrid motor control inverter assembly.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3)Location & Routingewd_type=routing;type=c;code=a3 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 |
||
| a3-1 (CBI) - a3-2 (CEI) | Ignition switch off | 10 kΩ or higher |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Reconnect the HV floor under wire from the rear hybrid motor control inverter assembly.
Reconnect the inverter terminal cover from the rear hybrid motor control inverter assembly.
OK
NG