MALFUNCTION DESCRIPTION
This DTC is stored when a short is detected in the hybrid motor control inverter assembly (motor inverter) or the hybrid vehicle transaxle assembly (motor (MG2)). The cause of this malfunction may be one of the following:
Motor inverter internal circuit malfunction
Open or short circuit
Iron particles or damage from foreign objects
For a description of the inverter.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P0D2D16
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed | Current flow to any phase of the motor (MG2) exceeds the threshold after the motor inverter is shut down due to a DTC indicating a motor inverter malfunction (overheating, overcurrent or circuit malfunction) being stored.
(1 trip detection logic) |
·
Hybrid motor control inverter assembly ·
Motor cable ·
Hybrid vehicle transaxle assembly |
Comes on | Master Warning:
Comes on |
Motor Generator | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
Drive the vehicle for approximately 10 minutes mainly using the engine.
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with ignition switch ON (READY) after repairs have been performed.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
DTC P0A7873 is stored after DTCs P0A789E and/or P1C5D19 are stored. After troubleshooting and repairing the malfunction which caused DTC P0A7873 to be stored, be sure to troubleshoot the other DTCs.
Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the hybrid motor control inverter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the hybrid motor control inverter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h (25 mph) for 1 minute and check that DTC P0A9000 is not output. If DTC P0A9000 is output, replace the hybrid vehicle transaxle assembly.
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A7873 for Motor generator control system is output | A |
| P0A7873 and DTCs other than the DTCs in the table below are output | B |
| P0A7873 and any DTCs in the table below are output | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| System | Relevant DTC | |
|---|---|---|
| Motor generator control system | P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
P0A7873 may be output as a result of the malfunctions indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the motor cable from the hybrid vehicle transaxle assembly.
Procedure1
Check the motor (MG2) for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle has been stopped.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(k1)Location & Routingewd_type=routing;type=c;code=k1 Click Connector(k1)Engine Compartment>Motor Cable>Hybrid Vehicle Transaxle Assemblyewd_type=component;type=c;code=k1;pinno=1,2,3 |
||
| k1-1 (W) - k1-2 (U) | Ignition switch off | 101.1 to 111.5 mΩ |
| k1-2 (U) - k1-3 (V) | Ignition switch off | 101.1 to 111.5 mΩ |
| k1-1 (W) - k1-3 (V) | Ignition switch off | 101.5 to 111.9 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(k1)Location & Routingewd_type=routing;type=c;code=k1 Click Connector(k1)Engine Compartment>Motor Cable>Hybrid Vehicle Transaxle Assemblyewd_type=component;type=c;code=k1;pinno=1,2,3 |
||
| k1-1 (W) - Body ground | Ignition switch off | 100 MΩ or higher |
| k1-2 (U) - Body ground | Ignition switch off | 100 MΩ or higher |
| k1-3 (V) - Body ground | Ignition switch off | 100 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Connect the motor cable.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Check the other DTCs that were output together with DTC P0A7873.
| Relevant DTC | |
|---|---|
| P0A789E | Drive Motor "A" Inverter Stuck On |
| P1C5D19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
DTC P0A7873 is stored after DTCs P0A789E and/or P1C5D19 are stored. After troubleshooting and repairing the malfunction which caused P0A7873 to be stored, be sure to troubleshoot the other DTCs.
| Proceed to |
|---|
| NEXT |
NEXT