MALFUNCTION DESCRIPTION
This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the motor (MG2) has been detected. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter | Hybrid motor control inverter assembly internal circuit malfunction |
| Hybrid vehicle transaxle assembly | ·
Motor (MG2) malfunction (entry of foreign matter, etc.) ·
Open or short circuit in the motor coils ·
Motor (MG2) permanent magnet magnetic force deterioration |
| Inverter low-voltage circuit | The connectors are not connected properly |
| Motor cable (for MG2) | ·
Defective motor cable (for MG2) connection condition ·
Open circuit or poor insulation in motor cable (for MG2) |
| Hybrid vehicle control ECU | Hybrid vehicle control ECU internal circuit malfunction |
When three-phase alternating current flows through the three-phase windings of the stator coil, a rotating magnetic field is generated in the motor (MG2). The system controls the rotation of the magnetic field in accordance with the rotating position and speed of the rotor. As a result, the permanent magnets provided in the rotor are pulled in the direction of rotation, generating torque. The generated torque is almost proportional to the amount of current. The system controls motor speed by regulating the frequency of the alternating current. Furthermore, the system properly controls the rotating magnetic field and the angle of the rotor magnets in order to generate high torque in an efficient manner, even at high speeds.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A9000 | Drive Motor "A" Performance | Motor magnetic force deterioration:
Decrease in the magnetic force of the motor (MG2) is detected. (1 trip detection logic) |
·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Hybrid motor control inverter assembly ·
Wire harness or connector ·
Hybrid vehicle control ECU |
Comes on | Master Warning:
Comes on |
Motor Generator | A |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY).
Drive the vehicle until the cumulative traveling time driving at a vehicle speed of 40 km/h (25 mph) or more is a few minutes. (It is not necessary to drive continuously at 40 km/h (25 mph) or more.)
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
Refer to the wiring diagram for the Shut Down Signal Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A9000 for Motor generator control system is output | A |
| P0A9000 and DTCs other than the DTCs in the table below are output | B |
| P0A9000 and Insulation Malfunction of Hybrid control system DTCs in the table below are output | C |
| P0A9000 and System Main Relay or High Voltage Circuit Malfunction of Hybrid control system DTCs in the table below are output | D |
| P0A9000 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | E |
| P0A9000 and Microcomputer malfunction of Hybrid control system DTCs in the table below are output | F |
| P0A9000 and Power source circuit malfunction of Motor generator control system DTCs in the table below are output | G |
| P0A9000 and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output | H |
| P0A9000 and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output | I |
| P0A9000 and System malfunction of Motor generator control system DTCs in the table below are output | J |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| System Main Relay or High Voltage Circuit Malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P0A1B1F | Generator Control Module Circuit Intermittent | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
| P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
| P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
| P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| Sensor and actuator circuit malfunction | Motor generator control system | P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure |
| P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
| P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
| P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
| P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | ||
| Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | ||
| System malfunction | Motor generator control system | P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A7A73 | Generator Inverter Actuator Stuck Closed | ||
| P0C1900 | Drive Motor "A" Execution Torque Performance | ||
P0A9000 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
E
F
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
G
H
I
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
J
Pre-procedure1
None.
Procedure1
Read the diagnosis related information.
| Tester Display |
|---|
| Diagnosis Related Information |
| Result | Proceed to |
|---|---|
| Diagnosis Related Information P312487 is output | A |
| Diagnosis Related Information P312487 is not output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P0A9000.
| Tester Display |
|---|
| Emergency Shutdown Signal |
| Result | Proceed to |
|---|---|
| The value of Emergency Shutdown Signal is ON | A |
| The value of Emergency Shutdown Signal is OFF | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Clear the DTCs.
Turn the ignition switch to ON (READY) with the shift lever in P.
Turn the air conditioning system on and wait for 1 minute with the engine stopped.
If the engine starts before 1 minute has elapsed, wait until it stops and then perform this step again.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A9000 or P0BFF1D is output | A |
| DTCs are not output | B |
| None of the above conditions are met | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None.
Procedure1
Clear the DTCs.
Turn the ignition switch to ON (READY).
Move the shift lever to D.
Depress the accelerator pedal halfway or more and accelerate the vehicle to 20 km/h (12.4 mph).
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A9000 or P0BFF1D is output | A |
| DTCs are not output | B |
| None of the above conditions are met | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT