Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0442914 REAR MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  P0BF512  Drive Motor "B" Phase V Current Sensor Circuit Short to Battery  P0BF514  Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open  P0BF51F  Drive Motor "B" Phase V Current Sensor Circuit Intermittent  P0BF912  Drive Motor "B" Phase W Current Sensor Circuit Short to Battery  P0BF914  Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open  P0BF91F  Drive Motor "B" Phase W Current Sensor Circuit Intermittent  P33C012  Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Battery  P33C014  Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Ground or Open  P33C01F  Drive Motor "B" Phase V Current Sensor Sub Circuit Intermittent  P33C512  Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Battery  P33C514  Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Ground or Open  P33C51F  Drive Motor "B" Phase W Current Sensor Sub Circuit Intermittent  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:


Rear inverter internal malfunction

Rear inverter assembly internal circuit malfunction


Rear inverter low-voltage circuit malfunction

The connectors are not connected properly


DESCRIPTION

The rear motor generator control ECU, which is built into the rear inverter assembly, monitors the rear inverter current sensor. These DTCs indicate the malfunction of rear inverter current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase V main sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase V main sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0BF51F Drive Motor "B" Phase V Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase V main sensor) when DTC P0C7A17 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Does not come on
Rear Motor Generator A
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase W main sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase W main sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P0BF91F Drive Motor "B" Phase W Current Sensor Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase W main sensor) when DTC P0C7A17 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Does not come on
Rear Motor Generator A
P33C012 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase V sub sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P33C014 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase V sub sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P33C01F Drive Motor "B" Phase V Current Sensor Sub Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase V sub sensor) when DTC P0C7A17 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Does not come on
Rear Motor Generator A
P33C512 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Battery Malfunction in rear motor inverter current sensor (phase W sub sensor) (Short to +B)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P33C514 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Ground or Open Malfunction in rear motor inverter current sensor (phase W sub sensor) (Open or short to ground)
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Comes on
Rear Motor Generator A
P33C51F Drive Motor "B" Phase W Current Sensor Sub Circuit Intermittent Short to +B, open or short to ground detected in rear motor inverter current sensor (phase W sub sensor) when DTC P0C7A17 or P1C5E19 is stored.
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly


Does not come on Master Warning:
Does not come on
Rear Motor Generator A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

5.

Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.

6.

Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more.

7.

Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more.

8.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

9.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK DTC OUTPUT (REAR MOTOR GENERATOR)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0BF512, P0BF514, P0BF51F, P0BF912, P0BF914, P0BF91F, P33C012, P33C014, P33C01F, P33C512, P33C514 or P33C51F is output A
P0BF512, P0BF514, P0BF51F, P0BF912, P0BF914, P0BF91F, P33C012, P33C014, P33C01F, P33C512, P33C514 or P33C51F is output and DTCs other than the DTCs in the table below are output B
P0BF512, P0BF514, P0BF51F, P0BF912, P0BF914, P0BF91F, P33C012, P33C014, P33C01F, P33C512, P33C514 or P33C51F is output and any DTCs in the table below are output C


Malfunction Content Relevant DTC
Power source circuit malfunction P06B31C Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P262C1C Drive Motor B" Control Module Offset Power Circuit Voltage Out of Range

HINT:

P0BF512, P0BF514, P0BF51F, P0BF912, P0BF914, P0BF91F, P33C012, P33C014, P33C01F, P33C512, P33C514 or P33C51F may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

C

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

2.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR