When the STA signal detected by the ECM and by the engine stop and start ECU do not match, the engine stop and start ECU stores DTC P061562 and blinks the stop and start cancel indicator.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory | DTC Output from | Priority | Note |
|---|---|---|---|---|---|---|---|---|
| P061562 | Starter Relay Signal Compare Failure | Both of the following conditions are met for 2 seconds or more (1 trip detection logic):
·
Normal communication with the ECM. ·
The STA signal detected by the ECM and engine stop and start ECU do not match. |
·
Wire harness or connector ·
ST NO. 1 relay ·
ECM ·
Engine stop and start ECU |
Blinks | DTC stored | Stop and Start | A | SAE Code: P0615 |
CONFIRMATION AFTER TROUBLESHOOTING
If the cable is disconnected from the auxiliary battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle to complete the refresh charge. The refresh charge is complete when the Data List item Status of auxiliary battery Charge Control changes from "Refresh Charge Mode". (Usually, idling the engine for 5 to 60 minutes with the auxiliary battery fluid temperature at 11°C (52°F) or higher, the refresh charge will be completed.)
If the GTS is not available and the Data List item Status of Auxiliary Battery Charge Control cannot be checked, charge the auxiliary battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
After the refresh charge completes, turn the ignition switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
Allow the engine to idle for 3 minutes after it is warmed up and check that the engine idle speed is within 50 rpm of the target idle speed.
Clear the DTCs.
Start the engine and warm it up.
Drive the vehicle at 7 km/h (4 mph) or more.
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
Stop the vehicle, move the shift lever to neutral and release the clutch pedal.
Keep the engine stopped by stop and start control for 1 second or more.
Depress the clutch pedal and start the engine.
Check that DTCs are not output.
STOP AND START SYSTEM OPERATION CHECK
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>OPERATION CHECK
Refer to DTC P061519.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>P061519
Before replacing the engine stop and start ECU, read the number of starter operations and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU, perform learning of the external backup boost converter (eco run vehicle converter assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
When the ECM is replaced on a vehicle with a non-specified auxiliary battery, it is necessary to perform auxiliary battery type switching.
Click hereEngine / Hybrid System>M15A-FKS (ENGINE CONTROL)>SFI SYSTEM>REGISTRATION
Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
For wire harness and connector inspection procedures and precautions, refer toGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>DTC CHECK / CLEAR
Pre-procedure1
Enter the following menus.
| Tester Display |
|---|
| Engine Starter Signal |
Procedure1
Read the values displayed on the GTS when the ignition switch is ON and START.
| GTS Display | Switch Condition | Normal Condition |
|---|---|---|
| Engine Starter Signal | Ignition switch ON | OFF |
| Engine Starter Signal | Ignition switch START | ON |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Enter the following menus.
| Tester Display |
|---|
| Starter SW |
Procedure1
Read the values displayed on the GTS when the ignition switch is ON and START.
| GTS Display | Switch Condition | Normal Condition |
|---|---|---|
| Starter SW | Ignition switch ON | OFF |
| Starter SW | Ignition switch START | ON |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG
Pre-procedure1
Disconnect the H45 certification ECU (smart key ECU assembly) connector.*1
*1: w/ Entry and Start System
Disconnect the A64 clutch start switch assembly connector.
Disconnect the A54 ECM connector.
Disconnect the A66 and A67 engine stop and start ECU connectors.
Remove the ST NO. 1 relay from the No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>TERMINALS OF ECU
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A54)Location & Routingewd_type=routing;type=c;code=A54 Click Connector(A54)Engine Compartment>Engine Room Main Wire>ECMewd_type=component;type=c;code=A54;pinno=30 |
||
| A54-30 (STA) - 2 (ST NO. 1 relay holder) | Always | Below 1 Ω |
| A54-30 (STA) -Body ground and other terminals | Always | 10 kΩ or higher |
| 2 (ST NO. 1 relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the H45 certification ECU (smart key ECU assembly) connector.*1
*1: w/ Entry and Start System
Disconnect the A64 clutch start switch assembly connector.
Disconnect the A54 ECM connector.
Disconnect the A66 and A67 engine stop and start ECU connectors.
Remove the ST NO. 1 relay from the No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>TERMINALS OF ECU
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A67,A54)Location & Routingewd_type=routing;type=c,c;code=A67,A54 Click Connector(A67)Instrument Panel>Engine Room Main Wire>Engine Stop and Start ECUewd_type=component;type=c;code=A67;pinno=21 Click Connector(A54)Engine Compartment>Engine Room Main Wire>ECMewd_type=component;type=c;code=A54;pinno=30 |
||
| A67-21 (STA) - 2 (ST NO. 1 relay holder) | Always | Below 1 Ω |
| A54-30 (STA) - 2 (ST NO. 1 relay holder) | Always | Below 1 Ω |
| A67-21 (STA) - A54-30 (STA) | Always | Below 1 Ω |
| A67-21 (STA) - Body ground and other terminals | Always | 10 kΩ or higher |
| A54-30 (STA) -Body ground and other terminals | Always | 10 kΩ or higher |
| 2 (ST NO. 1 relay holder) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
OK
NG
Pre-procedure1
Remove the ST NO. 1 relay from the No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (ST NO. 1 relay holder) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG