| *A | w/ Differential Pressure Sensor | *B | w/o Differential Pressure Sensor |
| ● | Non-reusable part | - | - |
| Procedure | Part NameCode |
|
|
|
|
|---|---|---|---|---|---|
| 14 | NO. 4 WATER BY-PASS HOSE | 16281 | - | - | - |
| 15 | NO. 2 VENTILATION HOSE | 12262 | - | - | - |
| 16 | WIRE HARNESS CLAMP BRACKET | - | ( )
|
- | - |
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during engine unit removal/installation are shown below.
2.REMOVE WIRE HARNESS CLAMP BRACKET
25760
3.REMOVE VACUUM TRANSMITTING HOSE ASSEMBLY (w/ Differential Pressure Sensor)
25733A
4.REMOVE VACUUM PIPE NO.1 (w/ Differential Pressure Sensor)
82219C
10.REMOVE SENSOR WIRE
Disengage the clamp.
Remove the bolt and sensor wire from the water inlet with thermostat sub-assembly.
11452D
12.REMOVE OIL LEVEL GAGE GUIDE
Using an 8 mm socket wrench, remove the bolt and engine oil level dipstick guide from the cylinder head sub-assembly.
Remove the O-ring from the engine oil level dipstick guide.
13.REMOVE WATER BY-PASS PIPE ASSEMBLY
16281
14.REMOVE NO. 4 WATER BY-PASS HOSE
12262
15.REMOVE NO. 2 VENTILATION HOSE
16.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the bolt and wire harness clamp bracket from the camshaft housing sub-assembly.
Using an 8 mm socket wrench, remove the 2 bolts and wire harness clamp bracket from the camshaft housing sub-assembly.