Home › Drivetrain › U340E (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSAXLE SYSTEM › 2011.08–2016.09
RM19S0E _52 Drivetrain _051465 U340E AUTOMATIC TRANSMISSION / TRANSAXLE _0248156 AUTOMATIC TRANSAXLE SYSTEM C

U340E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0717  Turbine Speed Sensor Circuit No Signal  


DESCRIPTION

This sensor detects the rotation speed of the input turbine. By comparing the input turbine speed signal (NT) with the speed sensor signal (SPD), the ECM detects the shift timing of the gears and appropriately controls the engine torque and hydraulic pressure in response to various conditions, thus performing smooth gear shifting.

DTC No. DTC Detection Condition Trouble Area
P0717 All conditions below are detected for 5 seconds or more (1 trip detection logic).
(a) Gear change is not being performed.
(b) Gear position: 3rd or 4th.
(c) T/M input shaft rpm: Less than 300 rpm.
(d) T/M output shaft rpm: 1000 rpm or more.
(e) Park/neutral position switch (NSW, R and L) is OFF.
(f) Shift solenoid valves, park/neutral position switch and vehicle speed sensor are in normal operation.
·

Wire harness or connector

·

Transmission revolution sensor (Speed sensor NT)

·

Automatic transaxle (clutch, brake or gear etc.)

·

ECM



MONITOR DESCRIPTION

The ECM detects the revolving signal from the transmission revolution sensor (input speed). The ECM outputs a gearshift signal by comparing the transmission revolution sensor signal with the speed sensor signal (SPD). While the vehicle is operating in the 3rd or 4th gear position in the shift position of D, if the input shaft speed is less than 300 rpm*1 although the output shaft speed is 1000 rpm*2 or more, the ECM detects the malfunction, illuminates the MIL and stores the DTC.

*1: Pulse is not output or is irregularly output.

*2: The vehicle speed is 50 km/h (31 mph) or more.

WIRING DIAGRAM

C243251E02
0.251,1.795 0.559,1.943 0.308,0.148 10 A48 0.251,1.951 2.291,2.259 2.040,0.308 10 Transmission Revolution Sensor (Speed Sensor NT) 1.388,0.902 1.691,1.060 0.303,0.158 10 NT+ 1.388,1.573 1.691,1.730 0.303,0.158 10 NT- 5.587,0.809 5.890,0.967 0.303,0.158 10 NT+ 5.587,1.48 5.890,1.637 0.303,0.158 10 NT- 1.74,0.711 1.859,0.869 0.119,0.158 10 2 1.74,1.37 1.859,1.528 0.119,0.158 10 1 5.258,0.809 5.548,0.966 0.290,0.156 10 B84 5.264,0.633 5.517,0.793 0.252,0.160 10 125 5.258,1.485 5.548,1.641 0.290,0.156 10 B84 5.264,1.308 5.517,1.469 0.252,0.160 10 124 5.807,2.072 6.160,2.230 0.353,0.158 10 ECM

PROCEDURE

1.INSPECT TRANSMISSION REVOLUTION SENSOR INSTALLATION
a.
C355230E01
2.615,0.031 2.823,0.198 0.208,0.167 10 false *b 0.479,0.031 0.688,0.198 0.208,0.167 10 false *a 2.677,1.792 2.885,1.958 0.208,0.167 10 false *c

Check the transmission revolution sensor installation.

OK:

The installation bolt is tightened properly and there is no clearance between the sensor and transmission case.


Text in Illustration
*a Correct
*b Incorrect
*c Clearance



OK

2.INSPECT TRANSMISSION REVOLUTION SENSOR

NG

SECURELY INSTALL OR REPLACE TRANSMISSION REVOLUTION SENSOR

2.INSPECT TRANSMISSION REVOLUTION SENSOR
C213110E06
0.052,0.018 0.419,0.273 0.367,0.256 10 *a 0.82,1.673 1.144,1.857 0.324,0.184 10 NT+ 2.273,1.69 2.597,1.874 0.324,0.184 10 NT- 0.985,1.673 1.505,1.116 false 1.951,1.107 2.38,1.669 false

a.

Disconnect the transmission revolution sensor connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (NT+) - 1 (NT-) 20°C (68°F) 560 to 680 Ω


Text in Illustration
*a Component without harness connected
(Transmission Revolution Sensor)



OK

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION REVOLUTION SENSOR - ECM)

NG

REPLACE TRANSMISSION REVOLUTION SENSOR

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION REVOLUTION SENSOR - ECM)
U158333E01
1.482,0.254 1.785,0.421 0.303,0.167 10 B84 0.048,0.027 0.258,0.210 0.210,0.182 10 *a 2.018,1.798 2.326,1.948 0.308,0.150 10 NT+ 1.915,1.407 2.196,1.77 false 1.382,1.798 1.690,1.948 0.308,0.150 10 NT- 1.829,1.407 1.56,1.77 false

a.

Connect the transmission revolution sensor connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B84-125 (NT+) - B84-124 (NT-) 20°C (68°F) 560 to 680 Ω
B84-125 (NT+) - Body ground Always 10 kΩ or higher
B84-124 (NT-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR