Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) › 2014.07–2015.06
RM19S0E _58 Vehicle Interior _051498 HEATING / AIR CONDITIONING _0248351 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1423  Pressure Sensor Circuit  


DESCRIPTION

This DTC is stored when refrigerant pressure is extremely low (0.176 MPa [1.8 kgf/cm2, 25.5 psi] or less) or extremely high (3.03 MPa [30.9 kgf/cm2, 439.4 psi] or higher). The air conditioner pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs the refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts the signal to a pressure value according to the sensor characteristics to control the compressor.

HINT:

Be sure to check the refrigerant volume first when this DTC is output because this DTC may also be stored if there is no refrigerant in the cycle.


DTC No. DTC Detection Condition Trouble Area
B1423 Either condition is met:
·

An open or short in the air conditioner pressure sensor circuit.

·

Refrigerant pressure on the high pressure side is extremely low or extremely high.


·

Air conditioner pressure sensor

·

Harness or connector

·

Cooler expansion valve

·

Cooler condenser assembly

·

Cooler dryer

·

Refrigerant pipe line

·

Air conditioning amplifier assembly

·

Amount of Refrigerant (too much or Insufficient)

·

Cooling fan system



WIRING DIAGRAM

E227901E01
2.217,0.701 2.324,0.850 0.107,0.149 10 + 2.235,1.087 2.324,1.253 0.089,0.166 10 - 2.089,1.484 2.323,1.628 0.234,0.144 10 PR 2.471,0.614 2.588,0.763 0.118,0.149 10 3 2.471,0.997 2.576,1.157 0.106,0.159 10 1 2.471,1.406 2.581,1.559 0.111,0.152 10 2 4.472,0.614 4.644,0.764 0.172,0.150 10 24 4.53,1.006 4.644,1.148 0.114,0.142 10 5 4.534,1.41 4.644,1.555 0.111,0.145 10 7 4.782,0.702 5.093,0.849 0.311,0.147 10 S5-3 4.782,1.099 5.136,1.241 0.354,0.142 10 SG-2 4.782,1.486 5.091,1.625 0.309,0.139 10 PRE 0.796,1.799 1.081,1.948 0.284,0.149 10 A23 0.796,1.951 2.818,2.128 2.022,0.177 10 Air Conditioner Pressure Sensor 4.304,1.895 4.567,2.047 0.264,0.152 10 F41 4.304,2.056 6.529,2.212 2.225,0.156 10 Air Conditioning Amplifier Assembly

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.
U158554E01
0.639,0.983 0.903,1.164 0.264,0.181 10 A23 0.059,0.029 0.229,0.190 0.170,0.161 10 *a 2.049,1.637 2.154,1.796 0.105,0.159 10 + 1.927,1.228 2.101,1.637 false

Disconnect the A23 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A23-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V


Text in Illustration
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)



OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIRCONDITIONING AMPLIFIER ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.
U158555E01
0.639,0.983 0.903,1.164 0.264,0.181 10 A23 0.059,0.029 0.229,0.190 0.170,0.161 10 *a 1.327,1.637 1.407,1.796 0.081,0.159 10 - 1.551,1.228 1.377,1.637 false

Disconnect the A23 air conditioner pressure sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A23-1 (-) - Body ground Always Below 1 Ω


Text in Illustration
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)



OK

3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIRCONDITIONING AMPLIFIER ASSEMBLY)
3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the air conditioner pressure sensor connector.


b.
U158590E01
0.348,0.781 0.604,0.962 0.256,0.181 10 F41 0.073,0.056 0.243,0.216 0.170,0.161 10 *a 0.506,1.484 0.810,1.628 0.304,0.144 10 PRE 1.356,0.931 0.884,1.57 false

Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F41-7 (PRE) - Body ground Ignition switch ON
A/C switch off
0.63 to 4.73 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)

HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor or wire harness. It is also possible that the amount of refrigerant may not be appropriate.




OK

4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.
U158590E01
0.348,0.781 0.604,0.962 0.256,0.181 10 F41 0.073,0.056 0.243,0.216 0.170,0.161 10 *a 0.506,1.484 0.810,1.628 0.304,0.144 10 PRE 1.356,0.931 0.884,1.57 false

Measure the voltage when the following conditions are met.

Measurement Condition
Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COOL
Blower Speed HI
A/C Switch*1 ON
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

*1: w/ Heater

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F41-7 (PRE) - Body ground Ignition switch ON
A/C switch on
0.63 to 4.73 V


Text in Illustration
*a Component with harness connected
(Air Conditioning Amplifier Assembly)

Result
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C




A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

13.CHECK COOLING FAN SYSTEM
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIRCONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A23 air conditioner pressure sensor connector.


b.

Disconnect the F41 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A23-3 (+) - F41-24 (S5- 3) Always Below 1 Ω
A23-3 (+) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIRCONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A23 air conditioner pressure sensor connector.


b.

Disconnect the F41 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A23-1 (-) - F41-5 (SG-2) Always Below 1 Ω
A23-1 (-) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A23 air conditioner pressure sensor connector.


b.

Disconnect the F41 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A23-2 (PR) - F41-7 (PRE) Always Below 1 Ω
A23-2 (PR) - Body ground Always 10 kΩ or higher




OK

8.CHECK FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.CHECK FOR AIR CONDITIONING SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.


c.

Evacuate the air conditioning system and check that vacuum can be maintained in it.

OK:

Vacuum can be maintained in the air conditioning system.


HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.




OK

9.CHARGE REFRIGERANT

NG

12.REPAIR AIR CONDITIONING SYSTEM LEAK
9.CHARGE REFRIGERANT
a.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).



NEXT

10.CHECK FOR DTC
10.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COOL
Blower Speed HI
A/C Switch*1 ON
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

*1: w/ Heater

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


OK:

DTC B1423 is not output


NOTICE:

If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leakage. Therefore, identify and repair the area where refrigerant leaks as necessary. The root cause of excessive refrigerant may be adding too much refrigerant.




OK

END

NG

11.INSPECT AIR CONDITIONER PRESSURE SENSOR
11.INSPECT AIR CONDITIONER PRESSURE SENSOR

OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

19.REPLACE AIR CONDITIONER PRESSURE SENSOR
12.REPAIR AIR CONDITIONING SYSTEM LEAK
a.

Identify the area where refrigerant leaks (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION).


b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.



NEXT

13.CHECK COOLING FAN SYSTEM
a.

Check that the cooling fan(s) operates normally.

HINT:

for 1NZ-FE: Refer to Cooling Fan Circuit (See page Engine / Hybrid System>1NZ-FE COOLING>COOLING FAN SYSTEM>Cooling Fan Circuit).

for 2NZ-FE: Refer to Cooling Fan Circuit (See page Engine / Hybrid System>2NZ-FE COOLING>COOLING FAN SYSTEM>Cooling Fan Circuit).





OK

14.CHARGE REFRIGERANT

NG

REPAIR COOLING FAN SYSTEM

14.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and then check for the DTC.




NEXT

15.CHECK FOR DTC
15.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COOL
Blower Speed HI
A/C Switch*1 ON
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

*1: w/ Heater

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant and check for the DTC. If the DTC is not output after this procedure, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair, it is necessary to replace the cooler dryer.



OK:

DTC B1423 is output




OK

16.REPLACE COOLER EXPANSION VALVE

NG

16.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL).

HINT:

Replace the cooler expansion valve with a new or normally functioning one because the cooler expansion valve is either stuck or clogged.




NEXT

17.CHARGE REFRIGERANT
17.CHARGE REFRIGERANT
a.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).



NEXT

18.CHECK FOR DTC
18.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COOL
Blower Speed HI
A/C Switch*1 ON
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

*1: w/ Heater

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a new or normally functioning one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other contaminants. In this case, clean or replace the cooler condenser assembly or pipes.



OK:

DTC B1423 is not output




OK

END

NG

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY WITH RECEIVER OR PIPES

19.REPLACE AIR CONDITIONER PRESSURE SENSOR
a.

Replace the air conditioner pressure sensor (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PRESSURE SENSOR>REMOVAL).



NEXT

20.CHECK FOR DTC
20.CHECK FOR DTC
a.

Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).

Measurement Condition
Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COOL
Blower Speed HI
A/C Switch*1 ON
R/F Switch Recirculation
Interior Temperature 25 to 35°C (77 to 95°F)

*1: w/ Heater

NOTICE:

If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


OK:

DTC B1423 is not output




OK

END

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY